Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Compare Treatment Efficacy Between Spot-Marking and Clip-Marking Targeted Axillary Dissection (TAD)Initially Node-positive Breast Cancer Patients After Neoadjuvant Systemic Treatments

23 de noviembre de 2026 actualizado por: Shu Wang, Peking University People's Hospital

Protocol for A Multicenter,Prospective, Open-label, Randomised Controlled Trial to Compare Treatment Efficacy Between Spot-Marking and Clip-Marking Targeted Axillary Dissection (TAD)Initially Node-positive Breast Cancer Patients After Neoadjuvant Systemic Treatments

  • This is a multicenter, prospective, open-label,randomised controlled trial to compare Spot-marking and Clip-marking TAD (targeted axillary dissection) in patients with initially node-positive breast cancer after neoadjuvant systemic treatments. Additionally, this trial still aims to explore the feasibility of utilizing PA/US(photoacoustic/ultrasound) device to identify Spot-ink marked lymph nodes.

  • Key Details :

    (1)Participants: 486 women (aged 18-80)with pathologically diagnosed primary invasive breast cancer (cT1N1M0 - cT3N3aM0) and axillary lymph node metastasis.

    (2) Design:

Patients are randomized 1:1 to two groups:

  • Group Spot-TAD (Spot-ink Marking TAD) :Patients receive ultasound-guided Spot-marking of axillary lymph node metastasis befor the neoadjuvant systemic treatments.Then, patients receive the standard neoadjuvant systemic treatments.After the neoadjuvant systemic treatments, patients receive TAD following with ALND(axillary lymph node dissection).

  • Group Clip-TAD (Clip Marking TAD) :Patients receive ultasound-guided Clip-marking of axillary lymph node metastasis befor theneoadjuvant systemic treatments .Then, patients receive the standard neoadjuvant systemic treatments .After the neoadjuvant systemic treatments , patients receive TAD following with ALND.

  • Photoacoustic imaging: Utilizing PA/US (photoacoustic/ ultrasound )device (The Resona Y ultrasound diagnostic system ,Shenzhen Mindray Bio-Medical Electronics Co., Ltd.,China)to perform photoacoustic imaging on 20 - 30 patients in Group Spot-TAD.

    (3)Primary Goals: The identification rates(IR) of axillary lymph dissection, including identification rates of targeted lymph nodes (TLNs)and sentinel lymph nodes(SLNs).

Secondary Goals : The false negative rate(FNR) and negative predicative value(NPV) of axillary lymph dissection.

The Imaging effect of utilizing PA/US device to identify Spot-ink marked lymph nodes.

-Why This Matters :

  1. Current guidelines recommend TAD for node-positive breast cancer patients before the neoadjuvant chemotherapy,but the TAD procedure only comprises TAD with clip-marking. This study further explores TAD using Spot-ink as a alternative method for patients with initially node-positive breast cancer after neoadjuvant chemotherapy with comparable efficacy and less side effects.
  2. This is the first clinical trial to explore the photoacoustic imaging of Spot-ink , but also the first clinical trial to apply photoacoustic imaging to the field of TAD. The results of this study contribute to expanding the application of photoacoustic imaging in the diagnosis and treatment of breast cancer.

Descripción general del estudio

Estado

Reclutamiento

Condiciones

Intervención / Tratamiento

Descripción detallada

-1.Scentific Background and Rationale:The axillary lymph node status is one of the most important factors to assist treatment and predict prognosis for breast cancer. There are two ways to evaluate the axillary lymph node status in nowadays clinical practices,including the sentinel lymph node biopsy(SLNB)and axillary lymph node dissection(ALND). When it comes to treat initially node-positive breast cancer patients after noadjuvant chemotherapy , the treatment efficacy of both the SLNB and the ALND couldn't correctly reflect the status of axliiary lymph node,which setting a barricade for physicians to choose suitble treatments for patients.A newly published surgerical approch has a potential to amend this defect,namely targeted axillary dissection(TAD).TAD is a procedure combines targeted lymph node biopsy (TLNB)and sentinel lymph node biopsy(SLND).TLNB is a method that tapping of biopsy-proven lymph node metastases befor neoadjuvant chemotherapy, and removing thhese targeted lymph nodes(TLNs) after neoadjuvant chemotherapy. According to the previous prospective trial, the TAD, combination of TLNB and SLNB, has acceptble treatment outcomes-the idenfication rates >90% and the false neative rate <10%. Corrently, there are many ways of marking TLNs, including 125I-radiolabelled seeds, clip and carbon particles and so on. However, many methods of marking lymph node have drawbacks. A newly reported marking method of carbon particles for TAD procedure, Spot-ink, has a potential to aviod those drawbacks and keep a acceptble treatment efficacy. The composition of Spot-ink includes water, glycerol, polysorbate 80, benzyl alcohol, simethicone, and high-purity carbon black. But the availability of Spot-ink amrking TAD still remains underexplored in China.

Photoacoustic imaging is a new type of imaging method. Its main principle is that when laser irradiates tissues, certain special molecules in the tissues are excited to generate ultrasonic signals. By detecting these ultrasonic signals, the distribution of these specific molecules in the tissues can be reconstructed. Photoacoustic imaging is non - invasive, real - time and highly sensitive, which makes it very suitable for imaging the breast and its axillary lymph nodes. At present, many studies have confirmed that by constructing photoacoustic/ultrasound devices combined with photoacoustic imaging and ultrasound imaging, the indocyanine green(ICG),methylene blue(MB)or carbon nanoparticle labeled axillary lymph nodes can be imaged. As a type of carbon nanoparticle, the photoacoustic effect of Spot-ink remains unclear. Moreover, through photoacoustic imaging, in theory, it is possible to study and explore the change patterns of long-term lymph node markers during neoadjuvant chemotherapy, and differentiate lymph nodes with different markings during axillary surgery.

This trial addresses this gap by evaluating whether Spot-marking TAD could correctly reflect eflect the status of axliiary lymph node while exploring the feasibility of utilizing PA/US device to identify Spot-ink marked lymph nodes.

  • 2.Study Objectives

    1. Primary Objectives:explore whether targeted axillary dissection (TAD) using Spot-ink marking in patients with initially node-positive breast cancer after neoadjuvant chemotherapy was more effective than TAD using Clip-marking after neoadjuvant therapy in patients of the same type.
    2. Secondary Objectives: explore the feasibility of utilizing PA/US device to identify Spot-ink marked lymph nodes.
  • 3.Study Population

    1. inclusion criteria:①women aged 18-80.②pathologically diagnosed primary invasive breast cancer (cT1N1M0 - cT3N3aM0).③ pathologically diagnosed axillary lymph node metastasis.④Patients planned for standardized neoadjuvant chemotherapy.⑤ECOG performance status 0-1.
    2. exclusion criteria:①Patients with distant metastases and patients with inflammatory breast cancer.②Pregnant and lactating patients.③Patients with previous surgery on the affected breast and axilla.
  • 4. Interventions

    1. targeted axliiary dissection(TAD):Patients receive ultasound-guided Spot-marking or Clip-marking of axillary lymph node metastasis before the neoadjuvant chemotherapy.Then, patients receive the standard neoadjuvant chemotherapy. After the neoadjuvant chemotherapy, patients receive TAD. Targeted axillary dissection(TAD) is a combination of SLNB and dissect the labeled metastatic lymph nodes(Targeted lymph node biopsy,TLNB). In this study , using the indocyanine green(ICG) and methylene blue to mapping the sentinel lymph node. Patient will receive ALND following with TAD.
    2. spot-ink:Before the neoadjuvant chemotherapy, using Spot-ink(GI Supply, Inc. ,USA) to mark the metastatic lymph nodes in Group A.The composition of Spot includes water, glycerol, polysorbate 80, benzyl alcohol, simethicone, and high-purity carbon black.
    3. clip:Before the neoadjuvant chemotherapy, using the clip to mark the metastasis lymph node of patient in Group B.
    4. photoacoustic/ultrasound(PA/US) device: The Resona Y ultrasound diagnostic system (Shenzhen Mindray Bio-Medical Electronics Co., Ltd.,China)was used to perform photoacoustic imaging on 20 - 30 patients in Group A. Utilizing this device to detect the spot-marking lymph nodes before the NAC,in the NAC and after the NAC.In the axillary surgery,using PA/US device to differentiate lymph nodes with different markings.
  • 5. Statistical Considerations

    1. Sample Size:In this trial, the recognition rate of axillary lymph nodes in TAD was used as the primary evaluation index, and a superiority test design was adopted.According to the content reported at the 2025 American Society of Clinical Oncology (ASCO) Annual Meeting, in the TAD trial using CLIP markers, the recognition rate of axillary lymph nodes was 89.6%, and in the TAD trial using carbon markers, the recognition rate of axillary lymph nodes was 96%.

The superiority margin was set at 0, and the ratio of the experimental group to the control group was 1:1. Then, under the conditions of α = 0.025 (one - sided test) and power (1 - β) = 80%, using SPSS 15.0, the sample size of each group was calculated to be 219 cases. Considering a 10% dropout rate, each group required 243 cases, with a total of 486 cases.

(2)Statistical Methods:The data were processed and analyzed using SPSS version 27.0. Descriptive statistical analysis: Qualitative indicators were described using frequencies, percentages, and composition ratios; quantitative indicators were represented using means, medians, and percentiles. For data comparison between two groups, the t - test was used for indicators that conformed to the normal distribution, and the Wilcoxon rank - sum test was used for those that did not. For qualitative indicators, the chi - square test, Fisher's exact estimation method, etc. were used. Kappa analysis was used to evaluate the reliability of research indicators. Two - sided tests were uniformly used for hypothesis testing. The test statistics and their corresponding P - values were given. P ≤ 0.05 was considered statistically significant, and P ≤ 0.01 was considered highly statistically significant.The main outcome indicators in the study included: recognition rate, false - negative rate, negative value predictive, etc. Recognition rate: The number of patients with at least one detected sentinel lymph node (SLN) divided by the total number of patients. A false - negative event refers to the situation where no metastatic lymph nodes were found during targeted axillary clearance, but metastatic lymph nodes were found during complete axillary lymph node dissection. The false - negative rate is the frequency of false - negative events. The negative predictive value is the number of true - negative results divided by the total number of patients with true - negative and false - negative test results. addition In, further subgroup analyses were conducted for patients with different numbers of tagged tumor - draining lymph nodes (TLN) and patients with different lymph node statuses after neoadjuvant therapy.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

486

Fase

  • Fase 2
  • Fase 3

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Ubicaciones de estudio

      • Beijing, Porcelana
        • Reclutamiento
        • Peking University People's Hospital
        • Contacto:
          • Peking University People's Hospital
          • Número de teléfono: 86-010-88324516
          • Correo electrónico: rmyyllwyh@163.com

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 80 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Femenino

Descripción

Inclusion Criteria:

  • The age is greater than 18 years old and less than 80 years old.
  • Patients with pathologically diagnosed primary invasive breast cancer (cT1N1M0 - cT3N3aM0).
  • Patients pathologically diagnosed with axillary lymph node metastasis.
  • Patients planned for standardized neoadjuvant chemotherapy.
  • ECOG performance status 0-1.

Exclusion Criteria:

  • Patients with distant metastases and patients with inflammatory breast cancer.
  • Pregnant and lactating patients.
  • Patients with previous surgery on the affected breast and axilla.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Group Spot-TAD

Spot-ink Marking TAD

Patients receive ultasound-guided Spot-marking or Clip-marking of axillary lymph node metastasis before the neoadjuvant systemic treatments.Then, patients receive the standard neoadjuvant systemic treatments. After the neoadjuvant systemic treatments, patients receive TAD.

Targeted axillary dissection(TAD) is a combination of SLNB and dissect the marked metastatic lymph nodes(Targeted lymph node biopsy,TLNB). In this study , using the indocyanine green(ICG) and methylene blue to mapping the sentinel lymph nodes. Patient will receive ALND following with TAD.

Utilizing PA/US device (The Resona Y ultrasound diagnostic system ,Shenzhen Mindray Bio-Medical Electronics Co., Ltd.,China)to perform photoacoustic imaging on 20 - 30 patients in Group Spot-TAD. Utilizing this device to detect the spot-marking lymph nodes before the neoadjuvant systemic treatments,in the neoadjuvant systemic treatments and after the neoadjuvant systemic treatments. In the axillary surgery,using PA/US device to differentiate lymph nodes with different markings.

Before the neoadjuvant systemic treatments, using Spot-ink(GI Supply, Inc. ,USA) to mark the metastatic lymph nodes in Group Spot-TAD .

The composition of Spot includes water, glycerol, polysorbate 80, benzyl alcohol, simethicone, and high-purity carbon black.

Experimental: Group Clip-TAD

Clip-Marking TAD

Patients receive ultasound-guided Spot-marking or Clip-marking of axillary lymph node metastasis before the neoadjuvant systemic treatments.Then, patients receive the standard neoadjuvant systemic treatments. After the neoadjuvant systemic treatments, patients receive TAD.

Targeted axillary dissection(TAD) is a combination of SLNB and dissect the marked metastatic lymph nodes(Targeted lymph node biopsy,TLNB). In this study , using the indocyanine green(ICG) and methylene blue to mapping the sentinel lymph nodes. Patient will receive ALND following with TAD.

Before the neoadjuvant systemic treatments, using the clip to mark the metastasis lymph nodes in Group Clip-TAD.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
identification rates(IR)
Periodo de tiempo: through study completion, an average of 6 months

The identification rates(IR) of axillary lymph dissection, including identification rates of targeted lymph nodes (TLNs)and sentinel lymph nodes(SLNs).

through study completion, an average of 6 months

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
false negative rate(FNR)
Periodo de tiempo: through study completion, an average of 6 months

The false negative rate(FNR) of axillary lymph dissection.

through study completion, an average of 6 months
negative predicative value(NPV)
Periodo de tiempo: through study completion, an average of 6 months

The negative predicative value(NPV) of axillary lymph dissection.

through study completion, an average of 6 months
Imaging effect of PA/US device
Periodo de tiempo: through study completion, an average of 6 months

The Imaging effect of utilizing PA/US device to identify Spot-ink marked lymph nodes.

through study completion, an average of 6 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Colaboradores

Investigadores

  • Silla de estudio: wang shu, Peking University People's Hospital

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

30 de mayo de 2026

Finalización primaria (Estimado)

31 de diciembre de 2027

Finalización del estudio (Estimado)

31 de diciembre de 2027

Fechas de registro del estudio

Enviado por primera vez

14 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

23 de noviembre de 2026

Publicado por primera vez (Actual)

24 de noviembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

24 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

23 de noviembre de 2026

Última verificación

1 de junio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • PekingUPH-RDL2025-29

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

producto fabricado y exportado desde los EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .