- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT02451618
Novel Epidermal Recording and Detection of Seizures (NERDS)
A Pilot Study of Seizure Detection in Neonates Using Multimodal Temporary Epidermal Electronics
Descripción general del estudio
Estado
Condiciones
Descripción detallada
Infants admitted to our NICU that require a standard EEG for clinical diagnosis will be approached for consent to test one of two new methods of EEG recording. Patients will be randomized to the new epidermal electronic system (EES) or the a hydrogel EKG electrode. All patients will continue to receive the standard of care EEG monitoring.
EES is slim new temporary tattoo technology that can easily be applied to the skin without requiring a technician or scrubbing and preparation as with standard EEG lead. The hydrogel EKG are FDA approved leads normally used to detect cardiac rhythm.
Specific Aims:
- To compare the rate of detection of neonatal seizures between a new method of recording electrical brain rhythms (EES or EKG) and the current standard of care (EEG, or electroencephalography.)
- To compare characterization of electrical brain activity between EES or EKG and EEG in the neonate.
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
California
-
San Diego, California, Estados Unidos, 92123
- Sharp Mary Birch Hospital for Women and Newborns
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Hospitalized neonates who already require continuous EEG recording for clinical care
- Parents signed informed consent
- CGA 44 weeks or less
Exclusion Criteria:
- Patient is moribund
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
---|
Epidermal Electronic System
EES, wireless tattoo electrode
|
Hydrogel electrode
EKG electrode, looking at hairline placement of electrodes.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Seizure detection
Periodo de tiempo: 24 hours
|
Seizures detected by study electrodes will be compared to seizures detected on conventional EEG recording.
|
24 hours
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
EEG characterization
Periodo de tiempo: 24 hours
|
Compare quality of brain activity with study leads vs standard leads
|
24 hours
|
Skin integrity from standard EEG vs study electrodes
Periodo de tiempo: 24 hours
|
Photographs will be taken to compare skin integrity after each electrode use.
|
24 hours
|
Hair removal from standard EEG vs study electrodes
Periodo de tiempo: 24 hours
|
If hair removal is necessary for study electrode placement.
|
24 hours
|
Otras medidas de resultado
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Edad gestacional
Periodo de tiempo: Al nacer
|
Al nacer
|
|
Apgar scores
Periodo de tiempo: Birth to 10 minutes of life
|
Apgars at 1, 5, 10, 15, and 20 minutes of life if applicable
|
Birth to 10 minutes of life
|
Subject received hypothermia treatment within 6 hours of life
Periodo de tiempo: Within 6 hours of life for 72 hours duration
|
Within 6 hours of life for 72 hours duration
|
|
Cause of seizure if known
Periodo de tiempo: Participants will be followed for the duration of hospital stay, an average of 10 days.
|
Date and time of seizures and etiology
|
Participants will be followed for the duration of hospital stay, an average of 10 days.
|
Anticonvulsant medication(s) subject received
Periodo de tiempo: Participants will be followed for the duration of hospital stay, an average of 10 days.
|
Phenobarbital, Levetiracetam, Phosphenytoin, Versed, Blinded Study Drug, Other
|
Participants will be followed for the duration of hospital stay, an average of 10 days.
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Mary J Harbert, MD, Sharp Mary Birch Hospital for Women & Newborns
Publicaciones y enlaces útiles
Publicaciones Generales
- Kim DH, Lu N, Ma R, Kim YS, Kim RH, Wang S, Wu J, Won SM, Tao H, Islam A, Yu KJ, Kim TI, Chowdhury R, Ying M, Xu L, Li M, Chung HJ, Keum H, McCormick M, Liu P, Zhang YW, Omenetto FG, Huang Y, Coleman T, Rogers JA. Epidermal electronics. Science. 2011 Aug 12;333(6044):838-43. doi: 10.1126/science.1206157. Erratum In: Science. 2011 Sep 23;333(6050):1703.
- Tharp BR. Neonatal seizures and syndromes. Epilepsia. 2002;43 Suppl 3:2-10. doi: 10.1046/j.1528-1157.43.s.3.11.x.
- Lawrence R, Inder T. Neonatal status epilepticus. Semin Pediatr Neurol. 2010 Sep;17(3):163-8. doi: 10.1016/j.spen.2010.06.010.
- Isaeva E, Isaev D, Savrasova A, Khazipov R, Holmes GL. Recurrent neonatal seizures result in long-term increases in neuronal network excitability in the rat neocortex. Eur J Neurosci. 2010 Apr;31(8):1446-55. doi: 10.1111/j.1460-9568.2010.07179.x. Epub 2010 Apr 6.
- van Rooij LG, Toet MC, van Huffelen AC, Groenendaal F, Laan W, Zecic A, de Haan T, van Straaten IL, Vrancken S, van Wezel G, van der Sluijs J, Ter Horst H, Gavilanes D, Laroche S, Naulaers G, de Vries LS. Effect of treatment of subclinical neonatal seizures detected with aEEG: randomized, controlled trial. Pediatrics. 2010 Feb;125(2):e358-66. doi: 10.1542/peds.2009-0136. Epub 2010 Jan 25.
- Nagarajan L, Ghosh S, Palumbo L. Ictal electroencephalograms in neonatal seizures: characteristics and associations. Pediatr Neurol. 2011 Jul;45(1):11-6. doi: 10.1016/j.pediatrneurol.2011.01.009.
- Ferree TC, Luu P, Russell GS, Tucker DM. Scalp electrode impedance, infection risk, and EEG data quality. Clin Neurophysiol. 2001 Mar;112(3):536-44. doi: 10.1016/s1388-2457(00)00533-2.
- Young GB, Campbell VC. EEG monitoring in the intensive care unit: pitfalls and caveats. J Clin Neurophysiol. 1999 Jan;16(1):40-5. doi: 10.1097/00004691-199901000-00003.
- Volpe JJ. Neonatal Seizures in Neurology of the Newborn, 4th ed. Philadelphia: WB Sanders, 2001: 178-214.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- Epidermal Electronics
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .