Outcomes of High Power Application in Catheter Ablation of Paroxysmal Atrial Fibrillation Guided by Unipolar Signal Modification.
Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].
Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Yksityiskohtainen kuvaus
Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation procedures in patients with paroxysmal atrial fibrillation (PAF) [1]. However, the incidence of atrial fibrillation (AF) recurrence remains high [2], mostly due to pulmonary vein (PV) reconnection [1], emphasizing the formation of transmural lesions to achieve complete conduction block along the ablation lines [3].
Previous studies have shown that elimination of the negative component of the unipolar electrogram (UP-EGM) during radiofrequency applications reflects transmural lesions. The persistence of such a negative component consistently corresponds to non-trans mural lesions [4].
The high-power short duration (HPSD) RF application applies to all RF energies delivered at more than 40 W [5]. Higher the power more is the resistive heating causing wider tissue injury [5]. The lesion size with HPSD is larger in width but lesser in depth compared to lower powers with longer duration [5]. In contrast, RF applications of lower power and longer duration result in larger dissipation of RF energies deep into the tissues due to conductive heating causing tissue destruction at greater depths [6]. Hence, there is a risk of collateral tissue damage [5].
HPSD ablation has been advocated as a means to minimize the risk of collateral organ damage as the lesions are smaller in depth. However, Maintaining a high power for a constant duration in the absence of a guide may not be the right strategy [5].
Unipolar waveform modification by complete elimination of the negative component may serve as a guide for HPSD ablation [5].
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Odotettu)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Paroxysmal atrial fibrillation
Exclusion Criteria:
- Age< 18 or > 80 years old,
- Atrium (LA) diameter > 50 mm,
- The presence of a mechanical mitral valve prosthesis,
- Left ventricular ejection fraction < 40%,
- Abnormal thyroid function,
- Contraindication to anticoagulant therapy,
- Current malignancy,
- Prior catheter or surgical AF ablation.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Yksittäinen
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Active Comparator: Standard power application
|
Standard power application
|
|
Active Comparator: High power application
|
Radiofrequency delivery was performed in a point-by point fashion and continuously (an inter-lesion distance of 6 mm) with 50 W and 70 W and the ablation time for each point is limited to 7s and repeated if needed till the Unipolar signal modification turn to complete positive R wave.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Ablation success at 6-month after the index procedure
Aikaikkuna: 6 months
|
Ablation success is defined as no recurrence with no anti-arrhythmic drugs by taking history of symptoms from the patient and by Holter 48 Hours.
|
6 months
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Julkaisuja ja hyödyllisiä linkkejä
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Odotettu)
Opiskelun aloitus
Ensisijainen valmistuminen (Odotettu)
Ensisijainen valmistuminen
Opintojen valmistuminen (Odotettu)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- atrial fibrillation ablation
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .