Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy
Evaluation of Instrumentation Time and Obturation Quality Using Two Different Pediatric Rotary File Systems in Primary Molar Pulpectomy :(A Randomized Clinical Trial)
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskeluyhteys
Opiskeluyhteys
- Nimi: Rania F. Mohamed, bachelor
- Puhelinnumero: +01000416751
- Sähköposti: rania.fathy@dentistry.cu.edu.eg
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Lapsi
Hyväksyy terveitä vapaaehtoisia
Kuvaus
Inclusion Criteria:
- Healthy Cooperative children.
- Children between the ages of four and eight years.
- Restorable teeth with irreversible pulpitis.
- Continuous bleeding after amputation of coronal pulp tissue.
Exclusion Criteria:
- Molars that exhibit physiologic root resorption in excess of one-third.
- Internal and external root resorption.
- Presence of dental abscess, sinus tract or excessive mobility.
- Acute spreading infection/cellulitis not manageable with local treatment.
- Large periapical/furcation lesion with poor prognosis.
- Teeth close to natural exfoliation.
- Children with known allergies to study materials or medications used.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Kaksinkertainen
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Active Comparator: Pediatric NiTi rotary files manufactured with AF-H Wire technology
Pediatric NiTi rotary files manufactured with AF-H Wire technology are designed to improve flexibility and cyclic fatigue resistance while facilitating efficient canal preparation.
Clinical studies have reported significantly reduced instrumentation time using this rotary system compared with conventional hand instrumentation.
Furthermore, the system has demonstrated favorable canal shaping ability and a high percentage of optimally obturated canals, indicating its effectiveness in pediatric pulpectomy procedures
|
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed.
Working length will be determined radiographically, and root canal preparation will be performed using pediatric NiTi rotary files manufactured with AF-H Wire technology with 1% sodium hypochlorite irrigation between files.
Instrumentation time will be recorded throughout the procedure.
The canals will then be dried and obturated with Metapex and zinc oxide eugenol, followed by restoration with glass ionomer cement and a stainless steel crown.
Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.
|
|
Kokeellinen: Pediatric NiTi rotary files manufactured with blue wire technology
Pediatric NiTi rotary files manufactured with blue wire technology are a newer pediatric rotary system developed using blue heat-treated NiTi technology.
Heat treatment enhances flexibility, resistance to cyclic fatigue, and fracture resistance, which are important characteristics when preparing the curved canals of primary teeth.
Laboratory studies have shown that blue wire pediatric rotary files exhibit excellent mechanical properties and superior cyclic fatigue resistance compared with several other pediatric rotary systems.
However, clinical evidence evaluating its performance in terms of instrumentation efficiency and obturation quality remains limited.
|
After preoperative radiographic assessment and administration of local anesthesia, lower primary molars will be isolated using a rubber dam and caries will be removed.
Working length will be determined radiographically, and root canal preparation will be performed using blue technology wire rotary files with 1% sodium hypochlorite irrigation between files.
Instrumentation time will be recorded throughout the procedure.
The canals will then be dried and obturated with Metapex, followed by restoration with glass ionomer cement and a stainless steel crown.
Obturation quality will be evaluated postoperatively using digital radiography according to the Coll and Sadrian criteria.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
instumentation time
Aikaikkuna: same visit while performing the pulpectomy
|
The total instrumentation time will be recorded from the start of the procedure until the canals are fully prepared.
Timing will begin with the insertion of the first file and will end after the final irrigation.
It will be measured in minutes using a stopwatch
|
same visit while performing the pulpectomy
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
obturation quality
Aikaikkuna: same visit after pulpectomy completion
|
The quality of obturation will be evaluated according to the criteria of Coll and Sadrian criteria (1996). The apical seal will measured in millimeters from the apical end of the canal filling material to the radiographic apex and scored as 1, 2, or 3.
|
same visit after pulpectomy completion
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Tutkijat
Tutkijat
- Opintojohtaja: Sara A. Mahmoud, Professor, Cairo University
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Arvioitu)
Opiskelun aloitus
Ensisijainen valmistuminen (Arvioitu)
Ensisijainen valmistuminen
Opintojen valmistuminen (Arvioitu)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- CU-rania-2026
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .