This Prospective Observational Study Aims to Evaluate the Capability of Ultra-high-resolution Photon-counting CT Angiography (UHR PCD-CTA) for Noninvasive Evaluation of Intracranial Venous Sinus Stents. The Study Will Compare Image Quality, Stent Visualization, Metal-related Artifacts, and Diagnosti
Evaluation of Ultra-High-Resolution Photon-Counting CT Angiography for Intracranial Venous Sinus Stent Assessment
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Yksityiskohtainen kuvaus
Intracranial venous sinus stenting has become an important treatment option for patients with symptomatic venous sinus stenosis, particularly those with idiopathic intracranial hypertension. Accurate imaging follow-up after stent placement is essential for evaluating stent patency, recurrent stenosis, and potential complications such as in-stent thrombosis or occlusion.
Conventional CT angiography (CTA) is commonly used for noninvasive follow-up after venous sinus stent implantation; however, accurate assessment of stented venous sinuses remains challenging due to metal-related artifacts. Blooming artifact caused by the high attenuation of metallic stent material may result in overestimation of stent thickness and obscuration of the stent lumen. In addition, beam-hardening artifacts from the stent and adjacent skull structures may further degrade image quality and reduce diagnostic confidence, potentially limiting the ability of CTA to detect clinically significant restenosis or thrombotic complications.
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Ilmoittautuminen
Yhteystiedot ja paikat
Opiskeluyhteys
Opiskeluyhteys
- Nimi: Jinhao Lyu, MD
- Puhelinnumero: +8615903562929
- Sähköposti: 330322990@qq.com
Tutki yhteystietojen varmuuskopiointi
- Nimi: Jinying He
- Sähköposti: 1527012389@qq.com
Opiskelupaikat
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Kiina, 100853
- Rekrytointi
- Chinese PLA General Hospital
-
Ottaa yhteyttä:
- Jinhao Lyu, MD
- Puhelinnumero: +8615903562929
- Sähköposti: 330322990@qq.com
-
Ottaa yhteyttä:
- Jinying He
- Puhelinnumero: +8613854153820
- Sähköposti: 1527012389@qq.com
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Adults aged ≥18 years.
- History of intracranial venous sinus stent implantation.
- Undergoing follow-up contrast-enhanced CT angiography after stent -placement.
- Available clinical and imaging data.
Exclusion Criteria:
- Severe motion artifacts affecting image interpretation.
- Contraindication to iodinated contrast media.
- Severe renal impairment preventing contrast-enhanced CT examination.
- Incomplete imaging data.
- Other conditions preventing reliable assessment of the venous sinus stent.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Ryhmien/kohorttien lukumäärä
Kohortit ja interventiot
Ryhmä/KohorttiRyhmä/Kohortti |
|---|
|
Patients With Intracranial Venous Sinus Stenosis
Patients with symptomatic intracranial venous sinus stenosis who underwent CT angiography before and after venous sinus stent implantation.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Agreement between UHR PCD-CTA and DSA for intracranial venous sinus stent patency
Aikaikkuna: 1-4 years
|
Agreement between ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) and digital subtraction angiography (DSA) for the assessment of intracranial venous sinus stent patency will be quantified using Cohen's kappa (κ) coefficient.
Stent patency will be classified according to the predefined diagnostic criteria, with DSA serving as the reference standard.
|
1-4 years
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Signal-to-noise ratio on UHR PCD-CTA
Aikaikkuna: 1-4years
|
Signal-to-noise ratio (SNR) will be calculated using CT attenuation and image noise measurements obtained from predefined regions of interest on UHR PCD-CTA images.
|
1-4years
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Tutkijat
Tutkijat
- Opintojen puheenjohtaja: Xin Lou, Chinese PLA General Hospital
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Opiskelun aloitus
Ensisijainen valmistuminen (Arvioitu)
Ensisijainen valmistuminen
Opintojen valmistuminen (Arvioitu)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- PCD-CT venous Stent
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .