This Prospective Observational Study Aims to Evaluate the Capability of Ultra-high-resolution Photon-counting CT Angiography (UHR PCD-CTA) for Noninvasive Evaluation of Intracranial Venous Sinus Stents. The Study Will Compare Image Quality, Stent Visualization, Metal-related Artifacts, and Diagnosti
Evaluation of Ultra-High-Resolution Photon-Counting CT Angiography for Intracranial Venous Sinus Stent Assessment
Przegląd badań
Status
Status
Warunki
Warunki
Szczegółowy opis
Intracranial venous sinus stenting has become an important treatment option for patients with symptomatic venous sinus stenosis, particularly those with idiopathic intracranial hypertension. Accurate imaging follow-up after stent placement is essential for evaluating stent patency, recurrent stenosis, and potential complications such as in-stent thrombosis or occlusion.
Conventional CT angiography (CTA) is commonly used for noninvasive follow-up after venous sinus stent implantation; however, accurate assessment of stented venous sinuses remains challenging due to metal-related artifacts. Blooming artifact caused by the high attenuation of metallic stent material may result in overestimation of stent thickness and obscuration of the stent lumen. In addition, beam-hardening artifacts from the stent and adjacent skull structures may further degrade image quality and reduce diagnostic confidence, potentially limiting the ability of CTA to detect clinically significant restenosis or thrombotic complications.
Typ studiów
Typ studiów
Zapisy (Szacowany)
Zapisy
Kontakty i lokalizacje
Kontakt w sprawie studiów
Kontakt w sprawie studiów
- Nazwa: Jinhao Lyu, MD
- Numer telefonu: +8615903562929
- E-mail: 330322990@qq.com
Kopia zapasowa kontaktu do badania
- Nazwa: Jinying He
- E-mail: 1527012389@qq.com
Lokalizacje studiów
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Chiny, 100853
- Rekrutacyjny
- Chinese PLA General Hospital
-
Kontakt:
- Jinhao Lyu, MD
- Numer telefonu: +8615903562929
- E-mail: 330322990@qq.com
-
Kontakt:
- Jinying He
- Numer telefonu: +8613854153820
- E-mail: 1527012389@qq.com
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Adults aged ≥18 years.
- History of intracranial venous sinus stent implantation.
- Undergoing follow-up contrast-enhanced CT angiography after stent -placement.
- Available clinical and imaging data.
Exclusion Criteria:
- Severe motion artifacts affecting image interpretation.
- Contraindication to iodinated contrast media.
- Severe renal impairment preventing contrast-enhanced CT examination.
- Incomplete imaging data.
- Other conditions preventing reliable assessment of the venous sinus stent.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Liczba grup / kohort
Kohorty i interwencje
Grupa / KohortaGrupa / Kohorta |
|---|
|
Patients With Intracranial Venous Sinus Stenosis
Patients with symptomatic intracranial venous sinus stenosis who underwent CT angiography before and after venous sinus stent implantation.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Agreement between UHR PCD-CTA and DSA for intracranial venous sinus stent patency
Ramy czasowe: 1-4 years
|
Agreement between ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) and digital subtraction angiography (DSA) for the assessment of intracranial venous sinus stent patency will be quantified using Cohen's kappa (κ) coefficient.
Stent patency will be classified according to the predefined diagnostic criteria, with DSA serving as the reference standard.
|
1-4 years
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Signal-to-noise ratio on UHR PCD-CTA
Ramy czasowe: 1-4years
|
Signal-to-noise ratio (SNR) will be calculated using CT attenuation and image noise measurements obtained from predefined regions of interest on UHR PCD-CTA images.
|
1-4years
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Krzesło do nauki: Xin Lou, Chinese PLA General Hospital
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Szacowany)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- PCD-CT venous Stent
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .