Smart Phone as a Screening and Evaluation Tool to Identify Knee Valgus During Dynamic Activities
Evaluation of the Use of the Smart Phone as a Screening and Evaluation Tool to Identify Knee Valgus During Dynamic Activities.
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Type d'étude
Type d'étude
Inscription (Réel)
Inscription
Contacts et emplacements
Lieux d'étude
-
-
Ohio
-
Westerville, Ohio, États-Unis, 43082
- Nationwide Children's Hospital Sports and Ortho PT Westerville
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Willingness to participate
- ability to perform a single leg squat, drop jump, and single leg drop without pain
Exclusion Criteria:
- lower extremity injury within 6 months prior to testing
- history of lower extremity surgery
- lower extremity weight bearing restrictions
- inability to follow directions
- neoprene/latex allergy
- Adhesive allergy
- Current neurological or developmental condition
- inability to attend follow-up session
- actively receiving Physical Therapy intervention for varus/valgus impairment
- Current pregnancy
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Nombre de groupes / cohortes
Cohortes et interventions
Groupe / CohorteGroupe / Cohorte |
|---|
|
smart phone inclinometer
For the smart phone analysis we will be using the tilt meter application which is a digital inclinometer application available on the I phone.
The phone will be placed in the vertical position utilizing the bubble level feature of the application.
The application will be set to display measurements to the closest tenth of the degree, set to log measurements every 0.2 seconds.
The subject will stand with knee extended to 0 degrees and quadriceps muscle activated and upper extremity support on opposite side of stance limb.
The phone will be placed in the vertical position on the anterior portion of the middle third of the subject's thigh attached using double sided adhesive tape.
Being placed as close as possible to level when attached to the anterior thigh with subject in single limb stance with a reading of less than 1 deg as minimum for correct set-up prior to testing.
Immediately prior to testing recording will be initiated logging measurements for later assessment.
|
|
2-D video analysis
two dimensional video analysis by first placing markers on the subject at the midpoint of the femoral condyles, midpoint of the ankle malleoli, and the proximal thigh along a line from the anterior superior iliac spine (ASIS) to the knee marker.
Testing will take place in front of a digital video camera with tape on the floor to give a reference point for the subject being tested.
Participants will be tested twice on day 1 and then again 5-9 days later.
Subjects will be allowed 2-3 practice trials prior to each test in order to allow the subject to feel comfortable with each test.
Following the practice trials the subject will perform 3 trials of each test on bilateral lower extremities.
This set up was consistent with the set up by Munro et al.
|
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during single leg squat
Délai: Baseline
|
Patient's dynamic lower extremity valgus during single leg squat will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Mesures de résultats secondaires
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during drop jump
Délai: Baseline
|
Patient's dynamic lower extremity valgus during a drop jump from a 12 inch step will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Autres mesures de résultats
Autres mesures de résultats
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during single leg landing drop jump
Délai: Baseline
|
Patient's dynamic lower extremity valgus during a single leg drop jump from a 12 inch step will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Les enquêteurs
Les enquêteurs
- Chercheur principal: Mitchell C Selhorst, DPT, Nationwide Children's Hospital
Publications et liens utiles
Publications générales
- Munro A, Herrington L, Carolan M. Reliability of 2-dimensional video assessment of frontal-plane dynamic knee valgus during common athletic screening tasks. J Sport Rehabil. 2012 Feb;21(1):7-11. doi: 10.1123/jsr.21.1.7. Epub 2011 Nov 15.
- Swenson DM, Collins CL, Fields SK, Comstock RD. Epidemiology of U.S. high school sports-related ligamentous ankle injuries, 2005/06-2010/11. Clin J Sport Med. 2013 May;23(3):190-6. doi: 10.1097/JSM.0b013e31827d21fe.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement primaire
Achèvement de l'étude (Réel)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- IRB14-00222
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .