Smart Phone as a Screening and Evaluation Tool to Identify Knee Valgus During Dynamic Activities
Evaluation of the Use of the Smart Phone as a Screening and Evaluation Tool to Identify Knee Valgus During Dynamic Activities.
Visão geral do estudo
Status
Status
Condições
Condições
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Contactos e Locais
Locais de estudo
-
-
Ohio
-
Westerville, Ohio, Estados Unidos, 43082
- Nationwide Children's Hospital Sports and Ortho PT Westerville
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Willingness to participate
- ability to perform a single leg squat, drop jump, and single leg drop without pain
Exclusion Criteria:
- lower extremity injury within 6 months prior to testing
- history of lower extremity surgery
- lower extremity weight bearing restrictions
- inability to follow directions
- neoprene/latex allergy
- Adhesive allergy
- Current neurological or developmental condition
- inability to attend follow-up session
- actively receiving Physical Therapy intervention for varus/valgus impairment
- Current pregnancy
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Número de grupos/coortes
Coortes e Intervenções
Grupo / CoorteGrupo / Coorte |
|---|
|
smart phone inclinometer
For the smart phone analysis we will be using the tilt meter application which is a digital inclinometer application available on the I phone.
The phone will be placed in the vertical position utilizing the bubble level feature of the application.
The application will be set to display measurements to the closest tenth of the degree, set to log measurements every 0.2 seconds.
The subject will stand with knee extended to 0 degrees and quadriceps muscle activated and upper extremity support on opposite side of stance limb.
The phone will be placed in the vertical position on the anterior portion of the middle third of the subject's thigh attached using double sided adhesive tape.
Being placed as close as possible to level when attached to the anterior thigh with subject in single limb stance with a reading of less than 1 deg as minimum for correct set-up prior to testing.
Immediately prior to testing recording will be initiated logging measurements for later assessment.
|
|
2-D video analysis
two dimensional video analysis by first placing markers on the subject at the midpoint of the femoral condyles, midpoint of the ankle malleoli, and the proximal thigh along a line from the anterior superior iliac spine (ASIS) to the knee marker.
Testing will take place in front of a digital video camera with tape on the floor to give a reference point for the subject being tested.
Participants will be tested twice on day 1 and then again 5-9 days later.
Subjects will be allowed 2-3 practice trials prior to each test in order to allow the subject to feel comfortable with each test.
Following the practice trials the subject will perform 3 trials of each test on bilateral lower extremities.
This set up was consistent with the set up by Munro et al.
|
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during single leg squat
Prazo: Baseline
|
Patient's dynamic lower extremity valgus during single leg squat will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during drop jump
Prazo: Baseline
|
Patient's dynamic lower extremity valgus during a drop jump from a 12 inch step will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Outras medidas de resultado
Outras medidas de resultado
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during single leg landing drop jump
Prazo: Baseline
|
Patient's dynamic lower extremity valgus during a single leg drop jump from a 12 inch step will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Mitchell C Selhorst, DPT, Nationwide Children's Hospital
Publicações e links úteis
Publicações Gerais
- Munro A, Herrington L, Carolan M. Reliability of 2-dimensional video assessment of frontal-plane dynamic knee valgus during common athletic screening tasks. J Sport Rehabil. 2012 Feb;21(1):7-11. doi: 10.1123/jsr.21.1.7. Epub 2011 Nov 15.
- Swenson DM, Collins CL, Fields SK, Comstock RD. Epidemiology of U.S. high school sports-related ligamentous ankle injuries, 2005/06-2010/11. Clin J Sport Med. 2013 May;23(3):190-6. doi: 10.1097/JSM.0b013e31827d21fe.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- IRB14-00222
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .