Smart Phone as a Screening and Evaluation Tool to Identify Knee Valgus During Dynamic Activities
Evaluation of the Use of the Smart Phone as a Screening and Evaluation Tool to Identify Knee Valgus During Dynamic Activities.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
Ohio
-
Westerville, Ohio, Stati Uniti, 43082
- Nationwide Children's Hospital Sports and Ortho PT Westerville
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Willingness to participate
- ability to perform a single leg squat, drop jump, and single leg drop without pain
Exclusion Criteria:
- lower extremity injury within 6 months prior to testing
- history of lower extremity surgery
- lower extremity weight bearing restrictions
- inability to follow directions
- neoprene/latex allergy
- Adhesive allergy
- Current neurological or developmental condition
- inability to attend follow-up session
- actively receiving Physical Therapy intervention for varus/valgus impairment
- Current pregnancy
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
|---|
|
smart phone inclinometer
For the smart phone analysis we will be using the tilt meter application which is a digital inclinometer application available on the I phone.
The phone will be placed in the vertical position utilizing the bubble level feature of the application.
The application will be set to display measurements to the closest tenth of the degree, set to log measurements every 0.2 seconds.
The subject will stand with knee extended to 0 degrees and quadriceps muscle activated and upper extremity support on opposite side of stance limb.
The phone will be placed in the vertical position on the anterior portion of the middle third of the subject's thigh attached using double sided adhesive tape.
Being placed as close as possible to level when attached to the anterior thigh with subject in single limb stance with a reading of less than 1 deg as minimum for correct set-up prior to testing.
Immediately prior to testing recording will be initiated logging measurements for later assessment.
|
|
2-D video analysis
two dimensional video analysis by first placing markers on the subject at the midpoint of the femoral condyles, midpoint of the ankle malleoli, and the proximal thigh along a line from the anterior superior iliac spine (ASIS) to the knee marker.
Testing will take place in front of a digital video camera with tape on the floor to give a reference point for the subject being tested.
Participants will be tested twice on day 1 and then again 5-9 days later.
Subjects will be allowed 2-3 practice trials prior to each test in order to allow the subject to feel comfortable with each test.
Following the practice trials the subject will perform 3 trials of each test on bilateral lower extremities.
This set up was consistent with the set up by Munro et al.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during single leg squat
Lasso di tempo: Baseline
|
Patient's dynamic lower extremity valgus during single leg squat will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during drop jump
Lasso di tempo: Baseline
|
Patient's dynamic lower extremity valgus during a drop jump from a 12 inch step will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Agreement in Dynamic lower extremity valgus angles during single leg landing drop jump
Lasso di tempo: Baseline
|
Patient's dynamic lower extremity valgus during a single leg drop jump from a 12 inch step will be measured using both 2-D video analysis and smart phone inclinometer analysis.
Measurements of 2-D and smart phone will be taken at the same time.
Analysis will be repeated at 2nd visit to assess the reliability of the measurements
|
Baseline
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Mitchell C Selhorst, DPT, Nationwide Children's Hospital
Pubblicazioni e link utili
Pubblicazioni generali
- Munro A, Herrington L, Carolan M. Reliability of 2-dimensional video assessment of frontal-plane dynamic knee valgus during common athletic screening tasks. J Sport Rehabil. 2012 Feb;21(1):7-11. doi: 10.1123/jsr.21.1.7. Epub 2011 Nov 15.
- Swenson DM, Collins CL, Fields SK, Comstock RD. Epidemiology of U.S. high school sports-related ligamentous ankle injuries, 2005/06-2010/11. Clin J Sport Med. 2013 May;23(3):190-6. doi: 10.1097/JSM.0b013e31827d21fe.
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- IRB14-00222
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .