Comparison of Double Lumen Tube Placement Techniques
Comparison of Placement of Double-lumen Endobronchial Tube Using GlideScope With 2 Different Stylet Configurations vs Standard Macintosh Laryngoscopy
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Description détaillée
Type d'étude
Type d'étude
Inscription (Réel)
Inscription
Phase
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Georgia
-
Atlanta, Georgia, États-Unis, 30322
- Emory University Hospital
-
Atlanta, Georgia, États-Unis, 30308
- Emory University Hospital Midtown
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Male and female patients requiring a double-lumen endobronchial tube placement for surgery at Emory University Hospital or Emory University Hospital Midtown
- Patients willing and able to provide written informed consent
Exclusion Criteria:
- Patients in whom a previously difficult airway manipulation was recorded on an anesthetic record
- Lung transplantation procedures, as underlying pulmonary disorder that will confound the SpO2 (peripheral capillary oxygen saturation) metric
- Any patient who is receiving anticoagulants in excess of a daily aspirin, patients with an International Normalized Ratio or INR >1
- Patients in whom one lung ventilation or placement of a double-lumen endobronchial tube is contraindicated
- Patients who require a rapid-sequence intubation
- Patients undergoing emergency procedures
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Recherche sur les services de santé
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Nombre de bras
Armes et Interventions
Groupe de participants / BrasGroupe de participants / Bras |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Expérimental: ZU-bend stylet with GlideScope technique
Subjects scheduled for thoracic surgery in which the surgeon requests lung isolation will undergo laryngoscopy and intubation using the ZU-bend with the GlideScope technique of a double lumen endobronchial tube (DLT) placement as part of the anesthesia procedure prior to surgery.
|
Laryngoscopy and intubation after induction of anesthesia will be done using the GlideScope and the ZU-bend stylet.
The ZU-bend is a specific shaping technique of the intubating stylet that is closely related to the GlideScope blade curvature.
Zu-bend stylet is withdrawn as a part of placement procedure during the DLT advancement.
Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
Laryngoscopy and intubation after induction of anesthesia will be done using the the GlideScope technique.
The GlideScope is a video laryngoscope that provides a real-time view of the airway and tube placement during intubation.
GlideScope is removed after DLT is in the trachea, and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
|
|
Comparateur actif: GlideScope with the GlideRite stylet
Subjects scheduled for thoracic surgery in which the surgeon requests lung isolation will undergo laryngoscopy and intubation using the GlideScope with the GlideRite stylet for placement of a double lumen endobronchial tube (DLT) as part of the anesthesia procedure prior to surgery.
|
Laryngoscopy and intubation after induction of anesthesia will be done using the the GlideScope technique.
The GlideScope is a video laryngoscope that provides a real-time view of the airway and tube placement during intubation.
GlideScope is removed after DLT is in the trachea, and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
Laryngoscopy and intubation after induction of anesthesia will be done with the GlideScope using the GlideRite stylet.
The GlideRite stylet is specifically designed to work with the GlideScope and provides the necessary rigidity and curvature to an otherwise flexible tube.
GlideRite stylet is withdrawn as a part of placement procedure during the DLT advancement.
Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
|
|
Comparateur actif: Macintosh blade and a regular DLT stylet
Subjects scheduled for thoracic surgery in which the surgeon requests lung isolation will undergo laryngoscopy and intubation using the direct laryngoscopy technique with the Macintosh blade and a regular double lumen endobronchial tube (DLT) stylet as part of the anesthesia procedure prior to surgery.
|
Direct laryngoscopy and intubation after induction of anesthesia will be done with the Macintosh blade and a regular double-lumen endobronchial tube (DLT) stylet.
The Macintosh blade is used to facilitate visualization of the larynx during double or single lumen endobronchial tube placement.
After intubation the Macintosh laryngoscope is removed and the confirmation of the successful placement of the double-lumen endobronchial tube in done in the standard fashion.
Autres noms:
Direct laryngoscopy and intubation after induction of anesthesia will be done with a regular double-lumen endobronchial tube (DLT) stylet and the Macintosh blade.
The DLT stylet is withdrawn as a part of placement procedure during the DLT advancement.
Thereafter, Macintosh laryngoscope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
|
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Mean Time to Place the Double-lumen Endobronchial Tube
Délai: during laryngoscope placement, up to 120 seconds
|
The time taken for successful intubation will be recorded by the anesthetist.
The total duration from the time the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2), an average of 120 seconds, will be recorded in seconds.
A higher duration noted is indicative of a longer time taken for successful intubation.
0 seconds (laryngoscope at patient's lips), (first End-tidal CO2 (EtCO2) detection)
|
during laryngoscope placement, up to 120 seconds
|
Mesures de résultats secondaires
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Success Rate of First Endobronchial Intubation Attempt
Délai: during laryngoscope placement, up to 120 seconds
|
The rate of first intubation attempt success will be recorded by the anesthetist.
A successful first attempt intubation is when the double-lumen endobronchial tube is placed during the initial laryngoscopy within 120 seconds.
The average time for successful intubation is 120 seconds, which is the time from when the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2).
Higher numbers of successful first attempt intubations indicate better rates of success of first endobronchial intubation attempts .
|
during laryngoscope placement, up to 120 seconds
|
|
Assessment of Difficulty of Intubation
Délai: during laryngoscope placement, up to 120 seconds
|
The ease of successful placement of the double-lumen endobronchial tube (DLT) will be assessed by the anesthetist's responses to a multi-question form which includes the following items that are scored; overall ease of intubation, laryngoscope insertion, glottic view, double-lumen endobronchial tube (DLT) delivery and placement.
The subjective scores range from 0-10; where 0=worst, 10=best.
The average time for successful intubation is 120 seconds, which is the time from when the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2).
|
during laryngoscope placement, up to 120 seconds
|
|
Number of Cases With Complications
Délai: during laryngoscope placement, up to 120 seconds
|
Number of cases with complications during intubation will be will be assessed by the anesthetist's responses to a multi-question form which includes the following items; blood on device, SpO2 (peripheral capillary oxygen saturation) <96%, lip and dental trauma and double-lumen endobronchial tube (DLT) cuff rupture.
The responses are recorded as Yes or No for each item.
A 'yes' response indicates a complication.
The average time for successful intubation is 120 seconds, which is the time from when the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2).
|
during laryngoscope placement, up to 120 seconds
|
|
Number of Cases of Voice Change
Délai: Up to 60 minutes after extubation
|
Any voice change in the patient after extubation will be assessed in the Post-Operative Admission Unit (PACU) by asking the patient if any change in voice is experienced (Yes/No).
The subjective answer given by the patient will be recorded.
The average time for the patient to sufficiently recover to respond is expected to be 60 minutes after extubation.
|
Up to 60 minutes after extubation
|
|
Throat Pain
Délai: Up to 60 minutes after extubation
|
Any voice change in the patient after extubation will be assessed in the Post-Operative Admission Unit (PACU) by recording the patient's response to the degree of pain experienced.
An analog pain scale will be used for scoring where: 0= no pain and 10= severe pain.
The average time for the patient to sufficiently recover to respond is expected to be 60 minutes after extubation.
|
Up to 60 minutes after extubation
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Les enquêteurs
Les enquêteurs
- Chercheur principal: Igor Zhukov, MD, Emory University
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement primaire
Achèvement de l'étude (Réel)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- IRB00081067
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .