Robot-Assisted Versus Free-Hand CT-Guided Flexible Guidewire Localization of Pulmonary Nodules
A Prospective Randomized Controlled Study of Robot-Assisted Versus Conventional Free-Hand CT-Guided Preoperative Flexible Guidewire Localization of Pulmonary Nodules
Small pulmonary nodules can be difficult to identify during thoracoscopic surgery. CT-guided flexible guidewire localization helps surgeons locate these nodules before resection. This study compares robot-assisted and conventional free-hand localization at Peking University Third Hospital. Sixty adults who require preoperative localization will be randomly assigned to one of two groups, with 30 participants in each group. Both groups will use the same type of flexible guidewire localization needle. The primary objective is to compare radiation exposure measured by dose-length product. The study will also assess puncture performance, localization accuracy, procedure duration, CT scan count, and procedure-related complications.
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Description détaillée
This investigator-initiated, prospective, single-center, randomized, parallel-group study compares robot-assisted and conventional free-hand CT-guided flexible guidewire localization before thoracoscopic pulmonary nodule resection. Written informed consent is obtained before enrollment.
Participants undergo a localization difficulty assessment. A computer-generated sequence assigns participants in a 1:1 ratio within low- and high-difficulty strata using block randomization. Both groups use the same type of flexible guidewire localization needle. In the robot-assisted group, CT images are used for three-dimensional reconstruction and trajectory planning. The physician confirms the target, entry point, angle, and depth, and inserts the needle with robotic trajectory guidance. Repeat CT confirms the needle position, and the guidewire is deployed after the planned target region has been reached. Post-localization CT assesses guidewire position and complications.
The procedure is open-label. The protocol specifies blinded assessment of post-localization CT images by two independent imaging physicians. Planned and actual puncture angles and depths, and the distance between the planned target and actual needle tip, are also recorded in the robot-assisted group. Conversion to free-hand localization is permitted when required for participant safety because of robotic system failure or failed registration, and the reason is recorded.
Continuous variables are summarized as means and standard deviations or medians and interquartile ranges, as appropriate. Between-group comparisons use the independent-samples t test or Mann-Whitney U test. Categorical variables are compared using the chi-square test or Fisher exact test.
Type d'étude
Type d'étude
Inscription (Estimé)
Inscription
Phase
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
Coordonnées de l'étude
- Nom: Fuxin Guo
- Numéro de téléphone: +86 15269757106
- E-mail: 15269757106@163.com
Lieux d'étude
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Chine, 100191
- Recrutement
- Peking University Third Hospital
-
Contact:
- Fuxin Guo
- Numéro de téléphone: +86 15269757106
- E-mail: 15269757106@163.com
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Age 18 to 80 years.
- A pulmonary nodule identified on preoperative high-resolution chest CT, with planned thoracoscopic wedge resection or segmentectomy.
- Maximum target nodule diameter of 20 mm or less.
- A pure ground-glass, part-solid (mixed ground-glass), or small solid nodule.
- A nodule considered difficult to identify by intraoperative inspection or palpation and requiring preoperative CT-guided localization.
- Ability to tolerate percutaneous pulmonary localization and subsequent video-assisted thoracoscopic surgery.
- Voluntary participation and written informed consent from the participant or a legally authorized representative.
Exclusion Criteria:
- Maximum target nodule diameter greater than 20 mm, or no need for preoperative localization in the investigator's judgment.
- No safe puncture trajectory that avoids major vessels, the heart, mediastinum, severe bullous disease, or other important structures.
- Severe pulmonary dysfunction that precludes percutaneous pulmonary puncture or thoracoscopic surgery.
- Coagulation dysfunction or inability to interrupt anticoagulant or antiplatelet treatment according to clinical standards.
- Clinically significant pneumothorax, pleural effusion, active infection, or another condition affecting safety assessment before localization.
- Pregnancy or breastfeeding.
- Inability to cooperate with positioning, breath-holding, or CT scanning.
- Severe ipsilateral pleural adhesions, previous thoracic surgery, or previous radiotherapy considered to compromise localization safety.
- Any other condition making participation unsuitable in the investigator's judgment.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Autre
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Nombre de bras
Armes et Interventions
Groupe de participants / BrasGroupe de participants / Bras |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Expérimental: Robot-Assisted CT-Guided Localization
Participants undergo robot-assisted CT-guided flexible guidewire localization before thoracoscopic resection. The uInterv C550-A system is used for CT-based reconstruction and trajectory planning. The physician confirms the target, entry point, angle, and depth and inserts the needle with robotic trajectory guidance. CT confirms satisfactory needle-tip placement before guidewire deployment. Final CT assesses guidewire position and complications. Both arms use the same type of flexible guidewire localization needle. |
The uInterv C550-A robotic puncture navigation and positioning system is used for CT-guided preoperative flexible guidewire localization of pulmonary nodules. CT images are used for three-dimensional reconstruction and trajectory planning. The physician confirms the target, skin entry point, puncture angle, and depth, and inserts the needle with robotic trajectory guidance. CT confirms satisfactory needle-tip placement before the flexible guidewire is deployed. A final CT scan assesses guidewire position and procedure-related complications. The same type of flexible guidewire localization needle is used in both groups.
Autres noms:
|
|
Comparateur actif: Conventional Free-Hand CT-Guided Localization
Participants undergo conventional free-hand CT-guided flexible guidewire localization before thoracoscopic resection. The physician selects the skin entry point and trajectory on CT images, inserts the localization needle under local anesthesia, and adjusts the needle as needed. CT confirms satisfactory needle-tip placement before guidewire deployment. Final CT assesses guidewire position and complications. Both arms use the same type of flexible guidewire localization needle. |
Percutaneous placement of a flexible guidewire localization needle using conventional manual trajectory planning and CT guidance before thoracoscopic resection. The physician inserts and adjusts the needle as needed. CT confirms satisfactory needle-tip placement before guidewire deployment, followed by final CT assessment. |
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Total Dose-Length Product
Délai: During the localization procedure, from the first CT scan to completion of the final CT scan after guidewire deployment
|
Total dose-length product (DLP), measured in mGy·cm, summed across all localization-related CT acquisitions, including the initial planning CT, CT acquisitions during needle placement, and the final post-deployment CT. |
During the localization procedure, from the first CT scan to completion of the final CT scan after guidewire deployment
|
Mesures de résultats secondaires
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
First-Attempt Puncture Success Rate
Délai: During the localization procedure
|
Percentage of participants with satisfactory needle-tip placement on the first puncture attempt without subsequent needle adjustment. |
During the localization procedure
|
|
Technical Localization Success Rate
Délai: From guidewire localization through completion of the subsequent thoracoscopic resection
|
Percentage of participants in whom flexible guidewire localization enables intraoperative identification and resection of the target pulmonary nodule during thoracoscopic surgery. |
From guidewire localization through completion of the subsequent thoracoscopic resection
|
|
Localization Deviation
Délai: During localization, on the CT scan confirming final needle-tip position before guidewire deployment
|
Distance in millimeters between the planned target point and the actual needle-tip position, measured on CT after needle placement. |
During localization, on the CT scan confirming final needle-tip position before guidewire deployment
|
|
Number of Needle Adjustments
Délai: During the localization procedure
|
Number of adjustments to needle position after the initial needle insertion during CT-guided localization. |
During the localization procedure
|
|
Number of Pleural Punctures
Délai: During the localization procedure
|
Number of needle punctures through the pleura during CT-guided localization. |
During the localization procedure
|
|
Localization Procedure Duration
Délai: During the localization procedure, from the first CT scan through completion of the final post-deployment CT scan
|
Elapsed time in minutes from the start of the first localization-related CT scan to completion of the final CT scan after flexible guidewire deployment. |
During the localization procedure, from the first CT scan through completion of the final post-deployment CT scan
|
|
Number of CT Acquisitions
Délai: During the localization procedure
|
Total number of CT acquisitions performed for localization, including the initial planning CT, scans during needle placement, and the final CT after guidewire deployment. |
During the localization procedure
|
|
Pneumothorax Rate
Délai: From localization through 2 months after localization
|
Percentage of participants with localization-related pneumothorax, assessed on post-localization CT and during follow-up. |
From localization through 2 months after localization
|
|
Intrapulmonary Hemorrhage Rate
Délai: From localization through 2 months after localization
|
Percentage of participants with localization-related intrapulmonary hemorrhage, assessed on post-localization CT and during follow-up. |
From localization through 2 months after localization
|
|
Guidewire Dislodgement or Migration Rate
Délai: From guidewire deployment through the subsequent thoracoscopic surgery; safety follow-up through 2 months after localization
|
Percentage of participants with dislodgement or migration of the localization guidewire after deployment, assessed on CT and during subsequent thoracoscopic surgery. Events are recorded during the 2-month safety follow-up; the guidewire is used for preoperative localization and is not intended to remain in place throughout follow-up. |
From guidewire deployment through the subsequent thoracoscopic surgery; safety follow-up through 2 months after localization
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Les enquêteurs
Les enquêteurs
- Chercheur principal: Fuxin Guo, Peking University Third Hospital
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Début de l'étude
Achèvement primaire (Estimé)
Achèvement primaire
Achèvement de l'étude (Estimé)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- M20260645
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .