Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Ultra Low Dose CT for CACS and AC of SPECT

25 septembre 2019 mis à jour par: University of Zurich

Usefulness of Ultra Low Dose Cardiac CT for Coronary Calcium Scoring and for Attenuation Correction of SPECT

The aim of the study is to compare the CACS obtained from standard dose CT to the CACS obtained from ultra-low-dose scans. Additionally, the usefulness of ultra-low-dose CT for AC of myocardial perfusion SPECT will be assessed.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Réel)

105

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Zurich, Suisse, 8091
        • Department of Nuclear Medicine, University Hospital Zurich

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Patients referred for myocardial perfusion SPECT
  • Male and Female subjects ≥18 years of age,
  • Written informed consent

Exclusion Criteria:

  • Pregnancy or breast-feeding
  • CACS of 0 after inclusion of 10 patients with CACS 0
  • Stents or implanted cardiac devices (valves, pace makers, ICD)
  • Coronary artery bypass grafts

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Diagnostique
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Autre: Standard dose CT, Ultra-low dose CT
Standard dose non-contrast enhanced CT (clinically indicated) and Ultra low dose non-contrast enhanced CT (as part of the trial)
Non-contrast enhanced CT for CACS and AC using a novel protocol for ultra low dose radiation dose exposure
Clinically indicated non-contrast enhanced CT for CACS and AC according to routine protocol

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Agreement and Correlation of Coronary Artery Calcium Score Obtained From Ultra-low-dose and Standard CT
Délai: 1 days

CAC and BA limits of agreement between coronary artery calcium score obtained from ultra-low-dose and standard CT.

Coronary artery calcium (CAC) is a measure for quantification of coronary artery calcification based on non-contrast enhanced CT, ranging from 0 (no calcifications) to infinite. It is an arbitrary unit. Increasing CAC means higher amounts of coronary artery calcifications and is associated with worse prognosis.

Bland-Altman (BA) analysis is a statistical method to compare two modalities or techniques assessing the same measure. Limits of agreement is defined as +/- twice the standard deviation of the differences between the reference method and the new modality/technique. Broader limits of agreement mean less accurate results obtained by the new modality/techniqe, while a 0 BA limit of agreement would theoretically reflect perfect agreement.

1 days
Intra-class Correlation Coefficient Between Segmental Relative Tracer Uptake From SPECT Datasets Reconstructed With AC Maps Based on Ultra-Low-Dose and Standard Dose CT
Délai: 1 day
For every patient, the CT images from 120 and 70 kVp-CT scans were used to create CTAC maps which were then used to reconstruct SPECT images, displayed as a 17-segment model polar plot with normalized percent tracer uptake given for every segment. Intra-class correlation was then applied to compare segmental relative tracer uptake. Analysis and the resulting correlation coefficient of 0.987 basically demonstrates interchangeability between the two datasets.
1 day

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Directeur d'études: Valerie Treyer, PhD, University of Zurich

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 novembre 2015

Achèvement primaire (Réel)

1 octobre 2016

Achèvement de l'étude (Réel)

1 octobre 2016

Dates d'inscription aux études

Première soumission

8 mai 2015

Première soumission répondant aux critères de contrôle qualité

27 mai 2015

Première publication (Estimation)

1 juin 2015

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

18 octobre 2019

Dernière mise à jour soumise répondant aux critères de contrôle qualité

25 septembre 2019

Dernière vérification

1 septembre 2019

Plus d'information

Termes liés à cette étude

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Ultra low dose non-contrast enhanced CT

S'abonner