- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT02458352
Ultra Low Dose CT for CACS and AC of SPECT
Usefulness of Ultra Low Dose Cardiac CT for Coronary Calcium Scoring and for Attenuation Correction of SPECT
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Zurich, Suisse, 8091
- Department of Nuclear Medicine, University Hospital Zurich
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Patients referred for myocardial perfusion SPECT
- Male and Female subjects ≥18 years of age,
- Written informed consent
Exclusion Criteria:
- Pregnancy or breast-feeding
- CACS of 0 after inclusion of 10 patients with CACS 0
- Stents or implanted cardiac devices (valves, pace makers, ICD)
- Coronary artery bypass grafts
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: Standard dose CT, Ultra-low dose CT
Standard dose non-contrast enhanced CT (clinically indicated) and Ultra low dose non-contrast enhanced CT (as part of the trial)
|
Non-contrast enhanced CT for CACS and AC using a novel protocol for ultra low dose radiation dose exposure
Clinically indicated non-contrast enhanced CT for CACS and AC according to routine protocol
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Agreement and Correlation of Coronary Artery Calcium Score Obtained From Ultra-low-dose and Standard CT
Délai: 1 days
|
CAC and BA limits of agreement between coronary artery calcium score obtained from ultra-low-dose and standard CT. Coronary artery calcium (CAC) is a measure for quantification of coronary artery calcification based on non-contrast enhanced CT, ranging from 0 (no calcifications) to infinite. It is an arbitrary unit. Increasing CAC means higher amounts of coronary artery calcifications and is associated with worse prognosis. Bland-Altman (BA) analysis is a statistical method to compare two modalities or techniques assessing the same measure. Limits of agreement is defined as +/- twice the standard deviation of the differences between the reference method and the new modality/technique. Broader limits of agreement mean less accurate results obtained by the new modality/techniqe, while a 0 BA limit of agreement would theoretically reflect perfect agreement. |
1 days
|
|
Intra-class Correlation Coefficient Between Segmental Relative Tracer Uptake From SPECT Datasets Reconstructed With AC Maps Based on Ultra-Low-Dose and Standard Dose CT
Délai: 1 day
|
For every patient, the CT images from 120 and 70 kVp-CT scans were used to create CTAC maps which were then used to reconstruct SPECT images, displayed as a 17-segment model polar plot with normalized percent tracer uptake given for every segment.
Intra-class correlation was then applied to compare segmental relative tracer uptake.
Analysis and the resulting correlation coefficient of 0.987 basically demonstrates interchangeability between the two datasets.
|
1 day
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Directeur d'études: Valerie Treyer, PhD, University of Zurich
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- USZ-2015-0072
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .
Essais cliniques sur Ultra low dose non-contrast enhanced CT
-
University of MinnesotaComplétéAnévrisme aortique, abdominal | Anévrisme aortique, thoraciqueÉtats-Unis
-
Daniel David Álamo ArceRecrutementDysfonctionnement de la vessieEspagne
-
Maastricht University Medical CenterInconnue
-
University Hospital, GrenobleComplétéFumeur | Cancer du poumon | Exposition aux radiationsFrance
-
University of CincinnatiNational Cancer Institute (NCI); Ohio Third FrontierActif, ne recrute pasImagerie TEP/TDMÉtats-Unis