Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Ultra Low Dose CT for CACS and AC of SPECT

25 september 2019 uppdaterad av: University of Zurich

Usefulness of Ultra Low Dose Cardiac CT for Coronary Calcium Scoring and for Attenuation Correction of SPECT

The aim of the study is to compare the CACS obtained from standard dose CT to the CACS obtained from ultra-low-dose scans. Additionally, the usefulness of ultra-low-dose CT for AC of myocardial perfusion SPECT will be assessed.

Studieöversikt

Studietyp

Interventionell

Inskrivning (Faktisk)

105

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

      • Zurich, Schweiz, 8091
        • Department of Nuclear Medicine, University Hospital Zurich

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Beskrivning

Inclusion Criteria:

  • Patients referred for myocardial perfusion SPECT
  • Male and Female subjects ≥18 years of age,
  • Written informed consent

Exclusion Criteria:

  • Pregnancy or breast-feeding
  • CACS of 0 after inclusion of 10 patients with CACS 0
  • Stents or implanted cardiac devices (valves, pace makers, ICD)
  • Coronary artery bypass grafts

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Diagnostisk
  • Tilldelning: N/A
  • Interventionsmodell: Enskild gruppuppgift
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Övrig: Standard dose CT, Ultra-low dose CT
Standard dose non-contrast enhanced CT (clinically indicated) and Ultra low dose non-contrast enhanced CT (as part of the trial)
Non-contrast enhanced CT for CACS and AC using a novel protocol for ultra low dose radiation dose exposure
Clinically indicated non-contrast enhanced CT for CACS and AC according to routine protocol

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Agreement and Correlation of Coronary Artery Calcium Score Obtained From Ultra-low-dose and Standard CT
Tidsram: 1 days

CAC and BA limits of agreement between coronary artery calcium score obtained from ultra-low-dose and standard CT.

Coronary artery calcium (CAC) is a measure for quantification of coronary artery calcification based on non-contrast enhanced CT, ranging from 0 (no calcifications) to infinite. It is an arbitrary unit. Increasing CAC means higher amounts of coronary artery calcifications and is associated with worse prognosis.

Bland-Altman (BA) analysis is a statistical method to compare two modalities or techniques assessing the same measure. Limits of agreement is defined as +/- twice the standard deviation of the differences between the reference method and the new modality/technique. Broader limits of agreement mean less accurate results obtained by the new modality/techniqe, while a 0 BA limit of agreement would theoretically reflect perfect agreement.

1 days
Intra-class Correlation Coefficient Between Segmental Relative Tracer Uptake From SPECT Datasets Reconstructed With AC Maps Based on Ultra-Low-Dose and Standard Dose CT
Tidsram: 1 day
For every patient, the CT images from 120 and 70 kVp-CT scans were used to create CTAC maps which were then used to reconstruct SPECT images, displayed as a 17-segment model polar plot with normalized percent tracer uptake given for every segment. Intra-class correlation was then applied to compare segmental relative tracer uptake. Analysis and the resulting correlation coefficient of 0.987 basically demonstrates interchangeability between the two datasets.
1 day

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Studierektor: Valerie Treyer, PhD, University of Zurich

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart

1 november 2015

Primärt slutförande (Faktisk)

1 oktober 2016

Avslutad studie (Faktisk)

1 oktober 2016

Studieregistreringsdatum

Först inskickad

8 maj 2015

Först inskickad som uppfyllde QC-kriterierna

27 maj 2015

Första postat (Uppskatta)

1 juni 2015

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

18 oktober 2019

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

25 september 2019

Senast verifierad

1 september 2019

Mer information

Termer relaterade till denna studie

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Kliniska prövningar på Kranskärlssjukdom

Prenumerera