Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Ultra Low Dose CT for CACS and AC of SPECT

25 september 2019 bijgewerkt door: University of Zurich

Usefulness of Ultra Low Dose Cardiac CT for Coronary Calcium Scoring and for Attenuation Correction of SPECT

The aim of the study is to compare the CACS obtained from standard dose CT to the CACS obtained from ultra-low-dose scans. Additionally, the usefulness of ultra-low-dose CT for AC of myocardial perfusion SPECT will be assessed.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Werkelijk)

105

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Zurich, Zwitserland, 8091
        • Department of Nuclear Medicine, University Hospital Zurich

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar en ouder (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Patients referred for myocardial perfusion SPECT
  • Male and Female subjects ≥18 years of age,
  • Written informed consent

Exclusion Criteria:

  • Pregnancy or breast-feeding
  • CACS of 0 after inclusion of 10 patients with CACS 0
  • Stents or implanted cardiac devices (valves, pace makers, ICD)
  • Coronary artery bypass grafts

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Diagnostisch
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Ander: Standard dose CT, Ultra-low dose CT
Standard dose non-contrast enhanced CT (clinically indicated) and Ultra low dose non-contrast enhanced CT (as part of the trial)
Non-contrast enhanced CT for CACS and AC using a novel protocol for ultra low dose radiation dose exposure
Clinically indicated non-contrast enhanced CT for CACS and AC according to routine protocol

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Agreement and Correlation of Coronary Artery Calcium Score Obtained From Ultra-low-dose and Standard CT
Tijdsspanne: 1 days

CAC and BA limits of agreement between coronary artery calcium score obtained from ultra-low-dose and standard CT.

Coronary artery calcium (CAC) is a measure for quantification of coronary artery calcification based on non-contrast enhanced CT, ranging from 0 (no calcifications) to infinite. It is an arbitrary unit. Increasing CAC means higher amounts of coronary artery calcifications and is associated with worse prognosis.

Bland-Altman (BA) analysis is a statistical method to compare two modalities or techniques assessing the same measure. Limits of agreement is defined as +/- twice the standard deviation of the differences between the reference method and the new modality/technique. Broader limits of agreement mean less accurate results obtained by the new modality/techniqe, while a 0 BA limit of agreement would theoretically reflect perfect agreement.

1 days
Intra-class Correlation Coefficient Between Segmental Relative Tracer Uptake From SPECT Datasets Reconstructed With AC Maps Based on Ultra-Low-Dose and Standard Dose CT
Tijdsspanne: 1 day
For every patient, the CT images from 120 and 70 kVp-CT scans were used to create CTAC maps which were then used to reconstruct SPECT images, displayed as a 17-segment model polar plot with normalized percent tracer uptake given for every segment. Intra-class correlation was then applied to compare segmental relative tracer uptake. Analysis and the resulting correlation coefficient of 0.987 basically demonstrates interchangeability between the two datasets.
1 day

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie directeur: Valerie Treyer, PhD, University of Zurich

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 november 2015

Primaire voltooiing (Werkelijk)

1 oktober 2016

Studie voltooiing (Werkelijk)

1 oktober 2016

Studieregistratiedata

Eerst ingediend

8 mei 2015

Eerst ingediend dat voldeed aan de QC-criteria

27 mei 2015

Eerst geplaatst (Schatting)

1 juni 2015

Updates van studierecords

Laatste update geplaatst (Werkelijk)

18 oktober 2019

Laatste update ingediend die voldeed aan QC-criteria

25 september 2019

Laatst geverifieerd

1 september 2019

Meer informatie

Termen gerelateerd aan deze studie

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Klinische onderzoeken op Coronaire hartziekte

Klinische onderzoeken op Ultra low dose non-contrast enhanced CT

Abonneren