Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Thyroid Ultrasound Elasticity (TrUE) Imaging

1 décembre 2019 mis à jour par: Stanislav Emelianov, Emory University

Multi-Angle Compound Shear Wave Elasticity Imaging for the Characterization of Thyroid Nodules

In this study the researchers will scan the thyroid nodules of patients scheduled for surgical removal of these nodules. During their preadmission testing, but prior to their surgery, the researchers will perform standard ultrasound and shear wave elasticity imaging (SWEI) scans of the thyroid nodules in these patients. Both images can be generated by the same ultrasound scanner and within the same imaging session without having to switch out any equipment. The results of the SWEI scans will be compared to the definitive diagnosis from pathology obtained after pathologists have examined the removed nodules post-operatively.

Aperçu de l'étude

Description détaillée

Thyroid ultrasound is a first-line procedure to assess patients with thyroid nodules. Unfortunately, standard ultrasound has low sensitivity, and thus low positive predictive value, for malignancy and many patients with thyroid nodules are referred for additional imaging studies or biopsy. Shear wave elasticity imaging (SWEI) is a non-invasive ultrasound technology that allows clinicians to assess the stiffness of tissues. In many solid tumors, increased stiffness is highly specific for underlying malignancy, and preliminary studies have shown this to be true for thyroid malignancies. Both standard sonography and SWEI can be performed on the same ultrasound equipment and within the same imaging session. Therefore, integrating SWEI into standard thyroid diagnostic workflow is a logical approach towards improving the positive predictive value of these first-line sonographic studies. Other studies have demonstrated the ability of SWEI techniques to differentiate benign from malignant thyroid nodules. However, shear wave techniques still need to overcome challenges before they can be successfully integrated into the clinical paradigm. These techniques still struggle to accurately classify follicular carcinomas and few have been validated in patients with multiple thyroid lesions, a scenario which is clinically common. The researchers believe that a multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To this end, this study will perform proof-of-concept studies of MAC-SWEI in thyroid patients undergoing standard ultrasound scans and compare the results of shear wave images to results from corresponding pathology.

Study participants will undergo a single SWEI session within their normally-scheduled preadmission testing during which both standard b-mode and shear images of the thyroid nodule(s) will be acquired. The 36 patients will be randomized to receive MAC-SWEI, standard SWEI, and ultrasound, or only standard SWEI and ultrasound.

Type d'étude

Observationnel

Inscription (Réel)

31

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Georgia
      • Atlanta, Georgia, États-Unis, 30308
        • Emory Univeristy Hospital Midtown

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Study participants will be recruited from patients of the Emory Healthcare system who are scheduled to have a thyroid biopsy, thyroidectomy, or cervical node biopsy.

La description

Inclusion Criteria:

  • Age ≥ 18 years old
  • Scheduled to undergo a thyroid biopsy, thyroidectomy, or cervical node biopsy

Exclusion Criteria:

  • None

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
MAC-SWEI, standard SWEI, ultrasound
Participants in this group will receive all three imaging techniques
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system. During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session. The generation of shear wave images consists of two important steps called "pushing" and "tracking". First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing. In the "tracking" mode, shear wave propagation is observed and recorded. Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Autres noms:
  • SWEI
The multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To assess the MAC-SWEI technique, shear wave images will be used to generate estimates of the relative stiffness of lesions via their normalized Young's modulus.
Autres noms:
  • MAC-SWEI
Standard SWEI, ultrasound
Participants in this group will receive two imaging techniques
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system. During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session. The generation of shear wave images consists of two important steps called "pushing" and "tracking". First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing. In the "tracking" mode, shear wave propagation is observed and recorded. Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Autres noms:
  • SWEI

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Determination of Malignancy by SWEI Imaging
Délai: Pre-operative visit (within 24 hours before surgery, on average)
As part of the pre-operative visit, participants will have imaging of their thyroid nodules. Established SWEI and MAC-SWEI techniques will be performed to identify malignant thyroid tissue.
Pre-operative visit (within 24 hours before surgery, on average)
Determination of Malignancy by Pathological Proof
Délai: Post-surgery (within 10 days after surgery, on average)
Tissue samples obtained during the participant's thyroid biopsy, thyroidectomy, or cervical node biopsy will be submitted to the pathology lab as part of the clinical standard of care. The pathology report will specify whether or not malignant cells were found in the tissue sample.
Post-surgery (within 10 days after surgery, on average)

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Accuracy of differentiating benign from malignant lesions between SWEI techniques
Délai: Pre-operative visit (within 24 hours before surgery, on average)
The ability of MAC-SWEI to differentiate benign from malignant lesions will be compared to the ability of standard SWEI to make this differentiation.
Pre-operative visit (within 24 hours before surgery, on average)

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Chercheur principal: Stanislav Emelianov, PhD, Emory University

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

23 octobre 2017

Achèvement primaire (Réel)

13 juillet 2018

Achèvement de l'étude (Réel)

13 juillet 2018

Dates d'inscription aux études

Première soumission

3 octobre 2017

Première soumission répondant aux critères de contrôle qualité

6 octobre 2017

Première publication (Réel)

12 octobre 2017

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

3 décembre 2019

Dernière mise à jour soumise répondant aux critères de contrôle qualité

1 décembre 2019

Dernière vérification

1 décembre 2019

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Oui

produit fabriqué et exporté des États-Unis.

Oui

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Ultrasound

S'abonner