- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT03307694
Thyroid Ultrasound Elasticity (TrUE) Imaging
Multi-Angle Compound Shear Wave Elasticity Imaging for the Characterization of Thyroid Nodules
Studienübersicht
Status
Bedingungen
Detaillierte Beschreibung
Thyroid ultrasound is a first-line procedure to assess patients with thyroid nodules. Unfortunately, standard ultrasound has low sensitivity, and thus low positive predictive value, for malignancy and many patients with thyroid nodules are referred for additional imaging studies or biopsy. Shear wave elasticity imaging (SWEI) is a non-invasive ultrasound technology that allows clinicians to assess the stiffness of tissues. In many solid tumors, increased stiffness is highly specific for underlying malignancy, and preliminary studies have shown this to be true for thyroid malignancies. Both standard sonography and SWEI can be performed on the same ultrasound equipment and within the same imaging session. Therefore, integrating SWEI into standard thyroid diagnostic workflow is a logical approach towards improving the positive predictive value of these first-line sonographic studies. Other studies have demonstrated the ability of SWEI techniques to differentiate benign from malignant thyroid nodules. However, shear wave techniques still need to overcome challenges before they can be successfully integrated into the clinical paradigm. These techniques still struggle to accurately classify follicular carcinomas and few have been validated in patients with multiple thyroid lesions, a scenario which is clinically common. The researchers believe that a multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To this end, this study will perform proof-of-concept studies of MAC-SWEI in thyroid patients undergoing standard ultrasound scans and compare the results of shear wave images to results from corresponding pathology.
Study participants will undergo a single SWEI session within their normally-scheduled preadmission testing during which both standard b-mode and shear images of the thyroid nodule(s) will be acquired. The 36 patients will be randomized to receive MAC-SWEI, standard SWEI, and ultrasound, or only standard SWEI and ultrasound.
Studientyp
Einschreibung (Tatsächlich)
Kontakte und Standorte
Studienorte
-
-
Georgia
-
Atlanta, Georgia, Vereinigte Staaten, 30308
- Emory Univeristy Hospital Midtown
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Age ≥ 18 years old
- Scheduled to undergo a thyroid biopsy, thyroidectomy, or cervical node biopsy
Exclusion Criteria:
- None
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Kohorten und Interventionen
Gruppe / Kohorte |
Intervention / Behandlung |
|---|---|
|
MAC-SWEI, standard SWEI, ultrasound
Participants in this group will receive all three imaging techniques
|
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system.
During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session.
The generation of shear wave images consists of two important steps called "pushing" and "tracking".
First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing.
In the "tracking" mode, shear wave propagation is observed and recorded.
Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Andere Namen:
The multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging.
To assess the MAC-SWEI technique, shear wave images will be used to generate estimates of the relative stiffness of lesions via their normalized Young's modulus.
Andere Namen:
|
|
Standard SWEI, ultrasound
Participants in this group will receive two imaging techniques
|
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system.
During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session.
The generation of shear wave images consists of two important steps called "pushing" and "tracking".
First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing.
In the "tracking" mode, shear wave propagation is observed and recorded.
Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Determination of Malignancy by SWEI Imaging
Zeitfenster: Pre-operative visit (within 24 hours before surgery, on average)
|
As part of the pre-operative visit, participants will have imaging of their thyroid nodules.
Established SWEI and MAC-SWEI techniques will be performed to identify malignant thyroid tissue.
|
Pre-operative visit (within 24 hours before surgery, on average)
|
|
Determination of Malignancy by Pathological Proof
Zeitfenster: Post-surgery (within 10 days after surgery, on average)
|
Tissue samples obtained during the participant's thyroid biopsy, thyroidectomy, or cervical node biopsy will be submitted to the pathology lab as part of the clinical standard of care.
The pathology report will specify whether or not malignant cells were found in the tissue sample.
|
Post-surgery (within 10 days after surgery, on average)
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Accuracy of differentiating benign from malignant lesions between SWEI techniques
Zeitfenster: Pre-operative visit (within 24 hours before surgery, on average)
|
The ability of MAC-SWEI to differentiate benign from malignant lesions will be compared to the ability of standard SWEI to make this differentiation.
|
Pre-operative visit (within 24 hours before surgery, on average)
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Hauptermittler: Stanislav Emelianov, PhD, Emory University
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- IRB00092785
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Ultrasound
-
Fujian Medical UniversityNoch keine RekrutierungLymphatische Metastasierung | Schilddrüsenneoplasmen | Papilläres Schilddrüsenkarzinom | Ret-Proto-Onkogen-MutationChina
-
IRCCS Fondazione Stella MarisUniversity of Pisa; Ministry of Health, Italy; Fondazione C.N.R./Regione Toscana...RekrutierungZerebralparese | Entwicklungsstörung | Pädiatrische neurologische StörungItalien
-
AnasonicNoch keine Rekrutierung
-
Centre Hospitalier Universitaire de la RéunionRekrutierung
-
University of California, San FranciscoAbgeschlossenNephrolithiasisVereinigte Staaten
-
China National Center for Cardiovascular DiseasesRekrutierungPerkutane Koronarintervention | Koronare Physiologie | Intravenöser UltraschallChina
-
Academisch Medisch Centrum - Universiteit van Amsterdam...AbgeschlossenDoppler-Messung der GebärmutterarterieNiederlande
-
ReCor Medical, Inc.RekrutierungHerz-Kreislauf-Erkrankungen | Gefäßerkrankungen | HypertonieVereinigte Staaten
-
Medical Corps, Israel Defense ForceRekrutierungTrauma-Verletzung | BlutungswundeIsrael
-
Chongqing Medical UniversityRekrutierungSchmerzhafte diabetische NeuropathieChina