In this study the researchers will scan the thyroid nodules of patients scheduled for surgical removal of these nodules. During their preadmission testing, but prior to their surgery, the researchers will perform standard ultrasound and shear wave elasticity imaging (SWEI) scans of the thyroid nodules in these patients. Both images can be generated by the same ultrasound scanner and within the same imaging session without having to switch out any equipment. The results of the SWEI scans will be compared to the definitive diagnosis from pathology obtained after pathologists have examined the removed nodules post-operatively.

Visão geral do estudo

Descrição detalhada

Thyroid ultrasound is a first-line procedure to assess patients with thyroid nodules. Unfortunately, standard ultrasound has low sensitivity, and thus low positive predictive value, for malignancy and many patients with thyroid nodules are referred for additional imaging studies or biopsy. Shear wave elasticity imaging (SWEI) is a non-invasive ultrasound technology that allows clinicians to assess the stiffness of tissues. In many solid tumors, increased stiffness is highly specific for underlying malignancy, and preliminary studies have shown this to be true for thyroid malignancies. Both standard sonography and SWEI can be performed on the same ultrasound equipment and within the same imaging session. Therefore, integrating SWEI into standard thyroid diagnostic workflow is a logical approach towards improving the positive predictive value of these first-line sonographic studies. Other studies have demonstrated the ability of SWEI techniques to differentiate benign from malignant thyroid nodules. However, shear wave techniques still need to overcome challenges before they can be successfully integrated into the clinical paradigm. These techniques still struggle to accurately classify follicular carcinomas and few have been validated in patients with multiple thyroid lesions, a scenario which is clinically common. The researchers believe that a multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To this end, this study will perform proof-of-concept studies of MAC-SWEI in thyroid patients undergoing standard ultrasound scans and compare the results of shear wave images to results from corresponding pathology.

Study participants will undergo a single SWEI session within their normally-scheduled preadmission testing during which both standard b-mode and shear images of the thyroid nodule(s) will be acquired. The 36 patients will be randomized to receive MAC-SWEI, standard SWEI, and ultrasound, or only standard SWEI and ultrasound.

Tipo de estudo

Observacional

Inscrição (Real)

31

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Georgia
      • Atlanta, Georgia, Estados Unidos, 30308
        • Emory Univeristy Hospital Midtown

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

Study participants will be recruited from patients of the Emory Healthcare system who are scheduled to have a thyroid biopsy, thyroidectomy, or cervical node biopsy.

Descrição

Inclusion Criteria:

  • Age ≥ 18 years old
  • Scheduled to undergo a thyroid biopsy, thyroidectomy, or cervical node biopsy

Exclusion Criteria:

  • None

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
MAC-SWEI, standard SWEI, ultrasound
Participants in this group will receive all three imaging techniques
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system. During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session. The generation of shear wave images consists of two important steps called "pushing" and "tracking". First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing. In the "tracking" mode, shear wave propagation is observed and recorded. Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Outros nomes:
  • SWEI
The multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To assess the MAC-SWEI technique, shear wave images will be used to generate estimates of the relative stiffness of lesions via their normalized Young's modulus.
Outros nomes:
  • MAC-SWEI
Standard SWEI, ultrasound
Participants in this group will receive two imaging techniques
All ultrasound images will be acquired by an in-house ultrasound technologist using a Verasonics Vantage (Verasonics Inc., Kirkland, Washington, USA) ultrasound system. During imaging, the technologist will position the Verasonics transducer, under b-mode guidance, in planes overlying the thyroid nodules approximating those obtained during previous clinical ultrasound scans.
Shear wave elasticity imaging (SWEI) is obtained during the standard ultrasound session. The generation of shear wave images consists of two important steps called "pushing" and "tracking". First, in the "pushing" mode, a long focused ultrasound beam is transmitted to perturb tissue, generating ultrasonic shear waves in tissue that propagate perpendicular to the direction of pushing. In the "tracking" mode, shear wave propagation is observed and recorded. Because the speed of shear waves is a function of Young's modulus, these data reveal information about the stiffness of underlying biological tissue.
Outros nomes:
  • SWEI

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Determination of Malignancy by SWEI Imaging
Prazo: Pre-operative visit (within 24 hours before surgery, on average)
As part of the pre-operative visit, participants will have imaging of their thyroid nodules. Established SWEI and MAC-SWEI techniques will be performed to identify malignant thyroid tissue.
Pre-operative visit (within 24 hours before surgery, on average)
Determination of Malignancy by Pathological Proof
Prazo: Post-surgery (within 10 days after surgery, on average)
Tissue samples obtained during the participant's thyroid biopsy, thyroidectomy, or cervical node biopsy will be submitted to the pathology lab as part of the clinical standard of care. The pathology report will specify whether or not malignant cells were found in the tissue sample.
Post-surgery (within 10 days after surgery, on average)

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Accuracy of differentiating benign from malignant lesions between SWEI techniques
Prazo: Pre-operative visit (within 24 hours before surgery, on average)
The ability of MAC-SWEI to differentiate benign from malignant lesions will be compared to the ability of standard SWEI to make this differentiation.
Pre-operative visit (within 24 hours before surgery, on average)

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Stanislav Emelianov, PhD, Emory University

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

23 de outubro de 2017

Conclusão Primária (Real)

13 de julho de 2018

Conclusão do estudo (Real)

13 de julho de 2018

Datas de inscrição no estudo

Enviado pela primeira vez

3 de outubro de 2017

Enviado pela primeira vez que atendeu aos critérios de CQ

6 de outubro de 2017

Primeira postagem (Real)

12 de outubro de 2017

Atualizações de registro de estudo

Última Atualização Postada (Real)

3 de dezembro de 2019

Última atualização enviada que atendeu aos critérios de controle de qualidade

1 de dezembro de 2019

Última verificação

1 de dezembro de 2019

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

produto fabricado e exportado dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Câncer, Tireóide

Ensaios clínicos em Ultrasound

Se inscrever