Effects of Myofascial Release on Pain, Disability and Electromyography of Erector Spinae in Chronic Low Back Pain
Effects of a Myofascial Release Protocol on Pain, Disability and Activation Pattern of Erector Spinae in Patients With Chronic Low Back Pain
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Valencia
-
Moncada, Valencia, Spagna, 46113
- CEU Cardenal Herrera University
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- low back pain for more than 3 months
Exclusion Criteria:
- vertebra fractures
- systemic disease (spondylitis, neoplasia, infectious, vascular, endocrine or metabolic disorders)
- spinal surgery
- advanced lumbar instability
- osteoporosis (in advanced stage)
- degenerative articular disease
- acute soft tissue inflammation
- rheumatoid arthritis
- osteomyelitis
- neuromuscular disease
- lower limb musculoskeletal injuries
- radiculopathy
- cauda equine syndrome
- myelopathy
- stenosis
- structural spine deformity (kyphoscoliosis...)
- pregnancy
- abundant menstruation
- IUD carrier
- mental disease
- dermatologic disease
- skin sensitivity
- aneurysma
- corticosteroids treatment
- anticoagulant therapy
- hypertension
- diabetes
- hemophilia
- leucemia
- rejection to manual contact
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Comparatore placebo: Placebo
|
A manual sham intervention will be applied to different muscles implicated in low back pain
|
|
Sperimentale: Myofascial treatment
Myofascial release techniques of different muscles implicated in low back pain
|
myofascial release techniques of different muscles implicated in low back pain
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Lumbar Pain
Lasso di tempo: 3 weeks
|
Short Form McGill Pain Questionnaire.
Visual Analogical Scale
|
3 weeks
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Disability
Lasso di tempo: 3 weeks
|
Roland Morris Disability Questionnaire
|
3 weeks
|
|
Fear Avoidance Beliefs
Lasso di tempo: 3 weeks
|
Fear Avoidance Beliefs Questionnaire
|
3 weeks
|
|
EMG Erector Spinae
Lasso di tempo: 3 weeks
|
Electromyography record (MEGAWIN 6000)
|
3 weeks
|
|
Lumbar ROM
Lasso di tempo: 3 weeks
|
Electrogonyometry Fastrak (Polhemus)
|
3 weeks
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Investigatori
Investigatori
- Direttore dello studio: Javier Romero, Dean, Health Science Faculty CEU-UCH
Pubblicazioni e link utili
Pubblicazioni generali
- FLOYD WF, SILVER PH. Function of erectores spinae in flexion of the trunk. Lancet. 1951 Jan 20;1(6647):133-4. doi: 10.1016/s0140-6736(51)91212-3. No abstract available.
- Alschuler KN, Neblett R, Wiggert E, Haig AJ, Geisser ME. Flexion-relaxation and clinical features associated with chronic low back pain: A comparison of different methods of quantifying flexion-relaxation. Clin J Pain. 2009 Nov-Dec;25(9):760-6. doi: 10.1097/AJP.0b013e3181b56db6.
- Grinnell F. Fibroblast mechanics in three-dimensional collagen matrices. J Bodyw Mov Ther. 2008 Jul;12(3):191-3. doi: 10.1016/j.jbmt.2008.03.005. Epub 2008 May 23.
- Fernandez-Perez AM, Peralta-Ramirez MI, Pilat A, Villaverde C. Effects of myofascial induction techniques on physiologic and psychologic parameters: a randomized controlled trial. J Altern Complement Med. 2008 Sep;14(7):807-11. doi: 10.1089/acm.2008.0117.
- Schleip R, Klingler W, Lehmann-Horn F. Active fascial contractility: Fascia may be able to contract in a smooth muscle-like manner and thereby influence musculoskeletal dynamics. Med Hypotheses. 2005;65(2):273-7. doi: 10.1016/j.mehy.2005.03.005.
- Saiz-Llamosas JR, Fernandez-Perez AM, Fajardo-Rodriguez MF, Pilat A, Valenza-Demet G, Fernandez-de-Las-Penas C. Changes in neck mobility and pressure pain threshold levels following a cervical myofascial induction technique in pain-free healthy subjects. J Manipulative Physiol Ther. 2009 Jun;32(5):352-7. doi: 10.1016/j.jmpt.2009.04.009.
- Ritvanen T, Zaproudina N, Nissen M, Leinonen V, Hanninen O. Dynamic surface electromyographic responses in chronic low back pain treated by traditional bone setting and conventional physical therapy. J Manipulative Physiol Ther. 2007 Jan;30(1):31-7. doi: 10.1016/j.jmpt.2006.11.010. Erratum In: J Manipulative Physiol Ther. 2007 Jul-Aug;30(6):472.
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- CEU-UCH-88
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .