Test of Long-Term Safety and Efficacy of Sirolimus-Permanent-Polymer Eluting Stent (Cypher)- and Sirolimus-Polymer-free Eluting Stents (PPS/PFS) Assessed by Optical Coherence Tomography (PPS/PFS-OCT)
Pilop Trial of OCT-determined Coverage of Permanent or Polymer-free Sirolimus Eluting Stent at Long Term
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
The mid-term efficacy of drug-eluting stents has been well-established, but there is an ongoing debate on the potential of an increased incidence of late stent thrombosis, particularly after discontinuation of thienopyridine therapy, as well as of delayed onset of restenosis or catch-up phenomenon with permanent polymer-based DES. The extent of strut coverage with reduction of exposed thrombogenic material has been shown to be associated with the inflammatory reaction grade and with the incidence of stent thrombosis. The optical coherence tomography (OCT) is an intravascular imaging modality based on light. The principle is similar to intravascular ultrasound, but due to the much shorter wave length of light, it offers a much better resolution up to 10µm, enabling the exact determination of strut coverage, neointimal thickness, vessel size, presence of dissections, and even the presence of inflammation.
Patients who received a polymer-free or a permanent-polymer sirolimus-eluting stent about 5 years ago without in-segment intervention since, will be evaluated by OCT regarding the healing pattern and the late lumen loss of the stent.
Tipo di studio
Tipo di studio
Iscrizione (Anticipato)
Iscrizione
Fase
Fase
- Fase 4
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Julinda Mehilli, MD
- Numero di telefono: 4582 +49 89 12 18
- Email: mehilli@dhm.mhn.de
Backup dei contatti dello studio
- Nome: Klaus Tiroch, MD
- Numero di telefono: 4578 +49 89 12 18
- Email: tiroch@dhm.mhn.de
Luoghi di studio
-
-
Bavaria
-
Munich, Bavaria, Germania, 81675
- Reclutamento
- Klinikum rechts der Isar
-
Contatto:
- Steffen Massberg, MD
- Numero di telefono: 4025 +49 89 12 18
- Email: massberg@dhm.mhn.de
-
Munich, Bavaria, Germania, 80636
- Reclutamento
- Deutsches Herzzentrum Muenchen
-
Contatto:
- Julinda Mehilli, MD
- Numero di telefono: 4582 +49 89 12 18
- Email: mehilli@dhm.mhn.de
-
Contatto:
- Klaus Tiroch, MD
- Numero di telefono: 4578 +49 89 12 18
- Email: tiroch@dhm.mhn.de
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Patients older than age 18 with with previous implantation of polymer-free or permanent-polymer sirolimus-eluting stents 5 years ago due to ischemic symptoms or evidence of myocardial ischemia in the presence of ≥ 50% stenosis located in native coronary vessels.
- Written, informed consent by the patient or her/his legally-authorized representative for participation in the study and assessment by OCT.
- In women with childbearing potential a negative pregnancy test is mandatory.
Exclusion Criteria:
- Intervention in the segment of the study stent after the index procedure
- Target lesion located in the left main trunk.
- In-stent restenosis with difficulty to pass the OCT device
- Acute myocardial infarction
- Known allergy to the study medications: Sirolimus, rapamycin, probucol or stainless steel.
- Pregnancy (present, suspected or planned) or positive pregnancy test.
- Patient's inability to fully cooperate with the study protocol.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Comparatore attivo: Arm 1
Sirolimus-Permanent-Polymer Eluting Stent
|
due randomization sirolimus-permanent-polymer eluting stent was implanted
Altri nomi:
|
|
Comparatore attivo: Arm 2
Sirolimus-Polymer-free Eluting Stent
|
due randomization sirolimus-polymer-free eluting stent was implanted
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Degree of stent strut coverage after 5 years assessed by OCT for each visible strut segment
Lasso di tempo: 5 years
|
5 years
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Percentage of malapposed strut assessed by OCT
Lasso di tempo: 5 years
|
5 years
|
|
Percentage of uncovered malapposed struts assessed by OCT
Lasso di tempo: 5 years
|
5 years
|
|
Morphologic differences of neointima between stents
Lasso di tempo: 5 years
|
5 years
|
|
Late lumen loss at 5 years assessed by OCT
Lasso di tempo: 5 years
|
5 years
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Klaus Tiroch, MD, Deutsches Herzzentrum Muenchen
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Anticipato)
Completamento primario
Completamento dello studio (Anticipato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Malattia cardiovascolare
- Malattie vascolari
- Arteriosclerosi
- Malattie arteriose occlusive
- Malattie cardiache
- Disfunsione dell'arteria coronaria
- Ischemia miocardica
- Malattia coronarica
- Effetti fisiologici delle droghe
- Agenti antinfettivi
- Agenti antineoplastici
- Agenti immunosoppressivi
- Fattori immunologici
- Agenti antibatterici
- Antibiotici, Antineoplastici
- Agenti antimicotici
- Sirolimo
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- GE IDE No. S03310
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .