Comparative In-Vivo Wetting Characteristics of Silicone Hydrogel Materials With Selected Lens Care Systems
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Texas
-
Fort Worth, Texas, Stati Uniti, 76134
- Contact Alcon Call Center at 1-888-451-3937 for Trial Locations
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Read and understand the Participant Information Sheet;
- Read, sign, and date the Informed Consent;
- Be a current silicone hydrogel contact lens wearer using the contact lenses under a frequent replacement (bi-weekly or monthly) daily wear modality;
- Be classified as symptomatic and a depositor at the end of the replacement period according to protocol-specified criteria;
- Agree to wear study contact lenses as directed for the duration of the study and maintain the appointment schedule;
- Best corrected visual acuity of 6/9 or better in each eye;
- Normal eyes with the exception of the need for visual correction;
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Known sensitivity or intolerance to any of the contact lenses or contact lens care products to be used;
- Monocular vision (only one eye with functional vision or only one eye fitted with contact lenses);
- Use of systemic medication which might interfere with contact lens wear or produce dry eye side effects;
- Systemic disease which might interfere with contact lens wear or produce dry eye side effects;
- Systemic or ocular allergies which might interfere with contact lens wear;
- Ocular disease which might interfere with contact lens wear;
- Active ocular infection;
- Use of any concomitant topical ocular medications during the study period;
- Previous ocular surgery;
- Pregnant, planning to become pregnant, or lactating at the time of enrollment;
- Participation in an investigational drug or device study within 30 days of entering this study;
- Other protocol-defined exclusion criteria may apply.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Separare
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Air Optix Aqua
Lotrafilcon B contact lenses with OFPM and BIOTRUE for 30 days each
|
Silicone hydrogel contact lenses, Phase 2
Altri nomi:
Contact lens care system, Phase 2
Altri nomi:
Contact lens care system, Phase 2
Silicone hydrogel contact lenses worn for 30 days, Phase 1
Altri nomi:
Contact lens care system used for 30 days, Phase 1
|
|
Comparatore attivo: Acuvue Oasys
Senofilcon A contact lenses with OFPM and BIOTRUE for 30 days each
|
Contact lens care system, Phase 2
Altri nomi:
Contact lens care system, Phase 2
Silicone hydrogel contact lenses worn for 30 days, Phase 1
Altri nomi:
Contact lens care system used for 30 days, Phase 1
Silicone hydrogel contact lenses, Phase 2
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Mean Ex-Vivo Total Lipid Uptake Per Lens
Lasso di tempo: Day 30
|
The contact lens was aseptically removed from the eye.
Lipids were extracted and analyzed using a proprietary High Performance Liquid Chromatography technique.
A lower value indicates a cleaner lens surface.
One eye (study eye) contributed to the mean.
|
Day 30
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Mean Non-Invasive Pre-Lens Tear Film Break Up Time (NIBUT)
Lasso di tempo: Day 30
|
The pre-lens tear film is the layer of tears located on top of the contact lens between the eyelid and the contact lens.
NIBUT (i.e., the time elapsed between eye opening after a blink and the appearance of the first dark spot within the tear film) was measured using a diffuse illumination source (Tearscope) and videotography.
A longer NIBUT indicates a more stable tear film and greater on-eye lens wettability.
One eye (study eye) contributed to the mean.
|
Day 30
|
|
LogMAR Time-Controlled Visual Acuity (TCVA)
Lasso di tempo: Day 30
|
Visual performance was measured binocularly (both eyes together) at two contrast levels using a validated Time Controlled Visual Acuity test (TCVA).
TCVA was recorded in VA units (1 VA unit=1 VA line=0.1 logMAR), with positive (+) values corresponding with VA better than 20/20 and negative (-) values worse than 20/20.
|
Day 30
|
|
Overall Comfort Measured With Visual Analog Scale (VAS)
Lasso di tempo: Day 30
|
The participant rated overall comfort on a 100-millimeter analog scale by marking a line that best corresponds to their eye comfort (0=very poor, 100=excellent).
Both eyes were rated together as a single, retrospective evaluation of the previous 3 days of wear.
|
Day 30
|
|
Overall Dryness Measured With Visual Analog Scale (VAS)
Lasso di tempo: Day 30
|
The participant rated overall dryness on a 100-millimeter analog scale by marking a line that best describes how dry their eyes feel (0=not at all dry, 100=very dry).
Both eyes were rated together as a single, retrospective evaluation of the previous 3 days of wear.
|
Day 30
|
|
Average Exposure Speed
Lasso di tempo: Day 30
|
Exposure speed (rate of increase in exposed lens surface % (areas not protected by tear film) after the first tear film break and before the second blink) was measured with a diffuse illumination source (Tearscope) and videotography.
Higher speeds indicate worse tear film dynamics.
One eye (study eye) contributed to the mean.
|
Day 30
|
|
Minimum Protected Area
Lasso di tempo: Day 30
|
Minimum protected area (i.e., minimum area of the lens (%) covered by the tear film during the interblink period) was measured using a diffuse illumination source (Tearscope) and videotography.
A higher value indicates a larger area of the tearfilm spread evenly over the lens (i.e., less area of tear film breakage).
One eye (study eye) contributed to the mean.
|
Day 30
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- M-12-043 / ID11-59
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .