Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Clinical Applications of Round Window Imaging Anatomy in Cochlear Implant Surgery

15 dicembre 2014 aggiornato da: MICHAL.LUNTZ, Bnai Zion Medical Center

Clinical Applications of Round Window High Resolution Computerised Tomography Anatomy in Cochlear Implant Surgery

The purpose of this study is to measure the size of the round window niche and its relation to the mastoid segment of the facial nerve and the mastoid cortex, using high resolution computerized tomography of the temporal bone, in order to assess preoperatively what is the extent of obstruction of the round window membrane and whether there is a surgical possibility of round window approach in the insertion of electrode array into the cochlea

Panoramica dello studio

Stato

Sconosciuto

Condizioni

Intervento / Trattamento

Descrizione dettagliata

The assessment of the anatomy of the round window will be executed using the stractured measuring software used for imaging of the Bnai Zion medical center (CARESTREAM PACS Ver. 11.0, CARSTREAM HEALTH INC.) in IAC window (centered at 700 with a total width of 4000) in the available zoom by the software (usually 400-800%).

Measuring the length (mm) and angle will be executed by the software's structured rulers.

Measuring protocol:

  1. Measured scans: one taken in an orbito-meatal plane
  2. Chosen slices: where both the round window niche and the external ear canal are seen on the same slice
  3. Distances measured:

    1. Distance 1: between the anterior edge of the round window niche and the cortex of the mastoid, with a minimal distance of 0.5mm to the posterior wall of the external ear canal
    2. Distance 2: between the posterior edge of the round window niche and the cortex of the mastoid, with a minimal distance of 0.3mm to the anterior edge of the mastoid segment of the facial nerve.
    3. Distance 3: the size of the round window niche (from its anterior to posterior edges)
    4. Distance 4: between the anterior (most medial) edge of the round window membrane to a point at least 0.3mm anterior to the mastoid segment of the facial nerve.
    5. Distance 5: between the posterior (most lateral) edge of the round window membrane to a point at least 0.3mm anterior to the mastoid segment of the facial nerve
    6. Distance 6: size of round window membrane (anterior/medial to posterior/lateral)
    7. Distance 7: between the lateral edges of distance 1 and 2 marking the cortical size of the "working channel" created between the lines (from the cortex to the round window).
  4. Angles measured:

    1. Between distance 1 and 7 - marking the angle of the "working channel" relatively to the cortex
    2. Between distance 1, passing in the middle of distance 3 to the middle of distance 6 - marking the angle of possible insertion from the working channel into the cochlea

Tipo di studio

Osservativo

Iscrizione (Effettivo)

100

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Haifa, Israele
        • Bnai Zion Medical Center

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

20 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

100 patient who were suffering from profound sensory neural hearing loss and underwent a high resolution computerized tomography of the temporal bone prior to cochlear implantation surgery

Descrizione

Inclusion Criteria:

  • age 20 years old or older
  • high resolution computerized tomography of the temporal bone (slices ≤1mm) before the surgery
  • on the measured slices both the round window niche and the posterior wall of the external ear canal are seen

Exclusion Criteria:

  • inner, middle or external ear malformation
  • temporal bone malformation
  • status post cochlear implant
  • status post temporal bone trauma
  • slices were the round window niche and the posterior wall of the external ear canal are not seen on the same slice

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Modelli osservazionali: Solo caso
  • Prospettive temporali: Retrospettiva

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
CT of the temporal bone

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Lasso di tempo
the size of round window niche and its relation to the cochlea
Lasso di tempo: january-june 2014 (six months)
january-june 2014 (six months)

Misure di risultato secondarie

Misura del risultato
Lasso di tempo
sizes of working channel from the mastoid cortex into the round window membrane and its relation to the mastoid sagment of the facial nerve
Lasso di tempo: january-june 2014 (six months)
january-june 2014 (six months)

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Investigatore principale: Michal Luntz, Prof., chair of otorhinolaryngology department at the Bnai Zion medical center

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 gennaio 2014

Completamento primario (Anticipato)

1 giugno 2015

Date di iscrizione allo studio

Primo inviato

20 marzo 2014

Primo inviato che soddisfa i criteri di controllo qualità

20 marzo 2014

Primo Inserito (Stima)

21 marzo 2014

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Stima)

16 dicembre 2014

Ultimo aggiornamento inviato che soddisfa i criteri QC

15 dicembre 2014

Ultimo verificato

1 dicembre 2014

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 0140-13-BNZ (Altro numero di sovvenzione/finanziamento: TRADIS GAT LTD. ISRAEL)

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .