Pre-operative Radiological Measurement to Assess Femur Rotational Alignment
Pre-operative Radiological Measurement of Proximal Tibia Angle to Assess Femur Rotational Alignment in Total Knee Arthroplasty
Purpose: This study outlines the benefits of the proximal tibia angle (PTA) in evaluation of the pre-operative individual condylar twist angle (CTA) in total knee arthroplasty.
Methods: Condylar twist angle and proximal tibia angle were obtained from 33 female healthy participants using computed tomography (CT). The CTA, angle between clinical transepicondylar axis and posterior condylar line were measured. The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line. The correlation between the CTA and the PTA was analyzed statistically with the linear regression.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Tipo di studio
Tipo di studio
Iscrizione (Anticipato)
Iscrizione
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Qiang He, MD
- Numero di telefono: 13572887175
- Email: heqianghonghui@163.com
Luoghi di studio
-
-
-
Xi'an, Cina
- Reclutamento
- Hong-hui Hospital
-
Contatto:
- Qiang He, MD
- Numero di telefono: 02983860818
-
-
Shanxi
-
Xi'an, Shanxi, Cina, 710054
- Reclutamento
- Honghui hospital
-
Contatto:
- Qiang He, MD
- Numero di telefono: 02983860818
- Email: heqianghonghui@163.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Osteoarthritis Varus knee deformity
Exclusion Criteria:
- Rheumatoid arthritis valgus knee OA previous knee surgeries posttraumatic arthritis
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
|---|
|
CT
Measured with computed tomography
|
|
plain Radiography
Measured with plain Radiography
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
proximal tibia angle (PTA)
Lasso di tempo: Four months
|
The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line.
|
Four months
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Condylar twist angle (CTA)
Lasso di tempo: Four months
|
The CTA is the angle between clinical transepicondylar axis and posterior condylar line
|
Four months
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Direttore dello studio: Jianbing Ma, MD, Honghui hospital
Pubblicazioni e link utili
Pubblicazioni generali
- Kanekasu K, Kondo M, Kadoya Y. Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2005 May;(434):193-7. doi: 10.1097/01.blo.0000156819.24866.8b.
- Savin L, Botez P, Mihailescu D, Predescu V, Grierosu C. Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty. Int Orthop. 2016 Sep;40(9):1855-60. doi: 10.1007/s00264-015-3110-2. Epub 2016 Jan 23.
- Kobayashi H, Aratake M, Akamatsu Y, Mitsugi N, Taki N, Saito T. Reproducibility of condylar twist angle measurement using computed tomography and axial radiography of the distal femur. Orthop Traumatol Surg Res. 2014 Dec;100(8):885-90. doi: 10.1016/j.otsr.2014.07.025. Epub 2014 Nov 20.
Studiare le date dei record
Studia le date principali
Inizio studio
Inizio studio
Completamento primario (Anticipato)
Completamento primario
Completamento dello studio (Anticipato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- XianHongHuiH
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .