Neurophysiologic Effects of Cervical Spinal Manipulation in Asymptomatic Individuals
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Healthy subjects.
- Minimum of 18 years old.
Exclusion Criteria:
- Pain in cervical region, shoulders or arms.
- History of trauma or disease in the cervical region or upper limb.
- Use of medication that could affect the outcomes (painkillers, NSAID, or anti depressives) during the last week.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Triplicare
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Manual manipulation
In the Manual manipulation group, the thrust was applied in the right side of C3/C4 with neutral flexion/extension, ipsilateral side bending and contralateral rotation.
Then, a low amplitude, high velocity thrust in rotation was delivered.
|
In the Manual manipulation group, the thrust was applied in the right side of C3/C4 with neutral flexion/extension, ipsilateral side bending and contralateral rotation.
Then, a low amplitude, high velocity thrust in rotation was delivered.
|
|
Comparatore attivo: Mechanical manipulation
In the Mechanical manipulation group, the Activator instrument was applied on the right transverse apophyses of C3.
|
In the Mechanical manipulation group, the Activator instrument was applied on the right transverse apophyses of C3.
|
|
Comparatore placebo: Placebo
The subjects were positioned in the same pre-manipulative position as the manual manipulation group, but the thrust didn't occur.
Instead, the position was hold for 3 seconds and then the subject's head returned passively to neutral position.
|
The subjects were positioned in the same pre-manipulative position as the manual manipulation group, but the thrust didn't occur.
Instead, the position was hold for 3 seconds and then the subject's head returned passively to neutral position.
|
|
Nessun intervento: Control
The subjects stayed in supine position and no intervention occurred.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Pressure pain thresholds
Lasso di tempo: Immediately after the intervention
|
To measure the pressure pain threshold, it was used an electronic pressure dynamometer FORCE ONE™ FDIX (Wagner Instruments - Greenwich, USA), with 1cm2 of surface.
The values were expressed in Kg/cm2.
The pressure was increased at a rate of 1 kg/cm2/s until the subject inform that the sense of pressure has become a sense of pain.
|
Immediately after the intervention
|
|
Pressure pain perception
Lasso di tempo: Immediately after the intervention
|
To evaluate the pressure pain perception, it was used a Visual Analogue Scale (VAS).
The pressure increased until 2,5 kg/cm2 and was hold for 5 seconds, and the subject used the VAS scale to record the pressure pain perception he felt.
|
Immediately after the intervention
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Muscle tone
Lasso di tempo: Immediately after the intervention
|
To measure muscle tone it was used the MyotonPro device.
It was used to evaluate those parameters both on the biceps and on the upper trapezius, bilaterally.
The device was located perpendicular to the middle point of each muscle and it were recorded 6 impulses in each one of them.
The non-neural tone was recorded as frequency.
|
Immediately after the intervention
|
|
Muscle stiffness
Lasso di tempo: Immediately after the intervention
|
To measure muscle stiffness it was used the MyotonPro device.
It was used to evaluate this parameter both on the biceps and on the upper trapezius, bilaterally.
The device was located perpendicular to the middle point of each muscle and it were recorded 6 impulses in each one of them.
The muscle stiffness was recorded as N/m.
|
Immediately after the intervention
|
|
Muscle elasticity
Lasso di tempo: Immediately after the intervention
|
To measure muscle elasticity it was used the MyotonPro device.
It was used to evaluate those parameters both on the biceps and on the upper trapezius, bilaterally.
The device was located perpendicular to the middle point of each muscle and it were recorded 6 impulses in each one of them.
The elasticity was indicated by logarithmic decrement.
|
Immediately after the intervention
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Nuno Nogueira, MSc, Instituto Politécnico da Saúde do Norte
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 20122017
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .