A Double Balloon Endoscopic Platform for ESD
Single Center Prospective Evaluation Utilizing a Double Balloon Accessory Device to Facilitate Complex Endoscopic Polypectomy in Large Intestine
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Endoscopic removal of Complex colon polyps (benign polyps >=2cm) is a technically challenging procedure. Complex benign polyps have a greater chance of becoming cancerous if not removed.
The DiLumen™ Endolumenal Interventional Platform is a non-sterile, single-use, close-fitting sleeve that fits securely over a standard endoscope to stabilize it in the large intestine, and facilitates use of the endoscope for optical visualization, diagnosis, and treatment. The device is indicated to ensure complete positioning of an endoscope in the large intestine and assist with optical visualization, diagnosis, and endoscopic treatment.
The device received 510k clearance on Dec 6, 2016. The study will evaluate performance of the device during routine, scheduled, endoscopic polyp removal for these large polyps.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Contatti e Sedi
Luoghi di studio
-
-
New York
-
Mineola, New York, Stati Uniti, 11501
- Winthrop-NYU Langone
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Subjects > 18 years of age
- Subjects scheduled for endoscopic removal of suspected complex adenomatous polyps in the large intestine which are sessile or polypoid lesions ≥ 2cm, near the ileocecal valve, dentate line, over a fold, or at a flexure; and or lesions tethered to the colon wall due to previous incomplete resection
- Subjects willing and able to give informed consent
- Subjects who in the opinion of the Principal Investigator have no medical contraindication to endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD)
Exclusion Criteria:
- Subjects with a contraindication to colonoscopy, including but not limited to active colitis, perforation, or stricture.
- Subjects with a history of open or laparoscopic colorectal surgery
- Subjects with a history of Inflammatory Bowel Disease (IBD)
- Subjects with a suspected malignancy on polyp assessment
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: Coorte
- Prospettive temporali: Prospettiva
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Endoscopic procedure
A double balloon endoscopic platform will be used during an ESD procedure
|
A DBA platform will be use din this registry study to facilitate ESD
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Ability to remove the complex polyp endoscopically
Lasso di tempo: Duration of Procedure
|
Was the lesion(s) able to be removed using the DiLumen Endolumenal Interventional Platform Device [Yes/No]
|
Duration of Procedure
|
|
Time taken for lesion removal
Lasso di tempo: Intervention start time until Lesion removal
|
Time for lesion(s) removal with the double balloon device after intervention begins
|
Intervention start time until Lesion removal
|
|
Device or Procedural Adverse Events
Lasso di tempo: Up to 72 hours
|
Colon perforation, colon mucosal injury, excess bleeding will be recorded
|
Up to 72 hours
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Stavros Stavropoulos, MD, Winthrop-NYU Langone Mineola, NY
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- DD-017
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .