SLAP Injury of the Shoulder Joint: Application Value of Deep Learning in Diagnosis
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
- Recognition of labrum images based on LeNet: axial and oblique coronal T2-fs images were used, and all images were corrected and standardized. LeNet identified the images with labrum of the shoulder joint, and the images with labrum structure of shoulder joint were selected from the complete sequence. In contrast, the images without labrum structure were deleted. All the data are divided into a training set (70%, 30% in training set as verification set), and the remaining 30% as a test set to evaluate the accuracy of model recognition. Enter the obtained results into the next step.
- Recognition and segmentation of glenoid lip of shoulder joint based on DenseNet: the labrum is recognized by DenseNet in the selected image. The labelimg software based on Python was used to locate the labrum coordinates and then input them into Python for recognition learning. All the data were divided into a training set (70% and 30% of the training set were selected as the verification set). The remaining 30% was used as the test set to evaluate the accuracy of model recognition. After identifying the labrum structure, the labrum structure is locally cut and enlarged to remove the redundant information and improve the recognition efficiency and accuracy. Finally, input the result to the next step.
- Recognition and grading of shoulder SLAP injury based on 3D-CNN: recognition and grading of input data through 3D-CNN model. 3D-CNN is divided into eight layers: input layer, hard wire layer H1, convolution layer C2, downsampling layer S3, convolution layer C4, downsampling layer S5, convolution layer C6 and output layer. 3D-CNN constructs a cube by stacking multiple consecutive frames and then uses a 3D convolution kernel in the cube. Through this structure, the feature images in the convolution layer will be connected with multiple adjacent frames in the previous layer to realize the information acquisition of continuous images. Similarly, the data is divided into a training set (70%, and then 30% of the training set is selected as the verification set), and the remaining 30% is used as the test set to evaluate the classification accuracy to identify whether there is labrum injury and grade the image with injury.
- Establish CNN combined model: after establishing the model for the axial and oblique coronal view according to the above process (1-3), according to the output characteristics of the CNN classification model, predict the probability of different grades before the output results, and the output results are based on these probabilities to select the expression form of the maximum possible probability. Our combined model averages the probabilities of these different classifications, calculates the final prediction probability, and then obtains the final joint model. The test set of the third step (including the mixed data of axial and coronal images) was used to verify the joint model.
Tipo di studio
Tipo di studio
Iscrizione (Anticipato)
Iscrizione
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: huishu Yuan, MD
- Numero di telefono: 15810245738
- Email: huishuy@bjmu.edu.cn
Backup dei contatti dello studio
- Nome: Ming Ni, MD
- Numero di telefono: +8613884794867
- Email: sdyingxiang2017@163.com
Luoghi di studio
-
-
Beijing
-
Beijing, Beijing, Cina, 010
- Peking University Third Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Bambino
- Adulto
- Adulto più anziano
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Without any treatment before imaging examination;
- MR of the shoulder joint was performed within 3 months before the operation and the image quality was good;
- Arthroscopic operation was performed in our hospital, and the operation records were complete.
Exclusion Criteria:
- History of shoulder surgery, tumor, or previous fracture;
- Unclear image, serious artifact, or incomplete clinical data.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: Caso di controllo
- Prospettive temporali: Retrospettiva
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Normal control group-Grade 0
Arthroscopic examination of the labrum was normal, and the labrum was intact without injury or tear.
|
The results of shoulder arthroscopy were taken as the gold standard, and MRI examination was taken as the research object.
|
|
Ligament injury -Grade 1
Arthroscopic examination of the shoulder showed labrum degeneration or injury, but no local or complete tear.
|
The results of shoulder arthroscopy were taken as the gold standard, and MRI examination was taken as the research object.
|
|
Ligament tear-Grade 2
Arthroscopy of the shoulder revealed partial or complete loss of labrum.
|
The results of shoulder arthroscopy were taken as the gold standard, and MRI examination was taken as the research object.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
SLAP Injury of the Shoulder Joint: Application Value of Deep Learning in Diagnosis
Lasso di tempo: 2021.10.1-2022.7.1
|
The model of deep learning was obtained for diagnosis and grading of SLAP injury and compared with the radiologists of different stages.
|
2021.10.1-2022.7.1
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Anticipato)
Inizio studio
Completamento primario (Anticipato)
Completamento primario
Completamento dello studio (Anticipato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- M2020458
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .