Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation

1 maggio 2026 aggiornato da: Ahmed jassim Ahmed alsubaya, Cairo University

Fixation of Mandibular Angle Fracture Using 3D Titanium Miniplate Versus Standard Two Plate Fixation a Randomized Clinical Trial

Hypothesis The investigators hypothesis that fixation of mandibular angle fractures using a 3D titanium miniplate will provide better occlusal bite force than intraoral fixation using the standard two-plate technique.

The investigators expect that this method will facilitate a faster recovery time for participants to regain baseline occlusion force.

Panoramica dello studio

Stato

Attivo, non reclutante

Condizioni

Intervento / Trattamento

Tipo di studio

Interventistico

Iscrizione (Stimato)

20

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Cairo, Egitto
        • Faculty of oral and dental medicine ,cairo university , oral and maxillodical department

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto

Accetta volontari sani

No

Descrizione

Inclusion Criteria:

  • • Age from 20 to 50years.

    • Male .
    • Patients with mandibular angle fractures.

Exclusion Criteria:

  • • Patients with contraindication to general anesthesia

    • Patients with comminuted angle fractures.
    • Patients with relevant systemic diseases contraindicating surgery or affecting bone healing.
    • Patients with infected condyle and coronoid fractures.
    • Gun-shot injuries.
    • Edentulous fractures.
    • Pathological fractures.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Triplicare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: fixation using standard Two plate titanium.

Intervention Name: Two Standard plat titanium system . Intervention Type: Device

Assigned Intervention:

Fixation using two titanium miniplates. The first plate is placed at the inferior border of the mandible from the buccal side, fixed with bicortical screws engaging both cortices. The second plate is positioned ~5 mm superior or at the external oblique ridge, fixed with monocortical screws to avoid dental root injury.

Fixation using two titanium miniplates. One plate at the inferior border of the mandible with bicortical screws. Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
Altri nomi:
  • two Titanium Miniplates Fixation ,Dual Miniplate Fixation ,Conventional Two-Plate Technique.
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws. Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line. Screws placed diagonally first.
Altri nomi:
  • Single 3D Titanium Plate, 2.0 mm Thickness, 6-Hole Rectangular 6-Hole ,3D Titanium Miniplate 3D Contoured Titanium Plate, 2.0 mm, 6-Hole
Sperimentale: 3D titanium miniplate

Intervention Name: 3D Titanium Miniplate (2.0 mm, 8-hole) Intervention Type: Device

Assigned Intervention:

Fixation with a single rectangular 2.0 mm 9-hole 3D titanium miniplate. Two diagonally opposite monocortical screws placed first, followed by the remaining two. The plate is contoured with crossbars perpendicular and struts parallel to the fracture line. The upper crossbar is positioned subapically. Fixation is on the lateral cortex or external oblique ridge with proper adaptation.

Fixation using two titanium miniplates. One plate at the inferior border of the mandible with bicortical screws. Second plate ~5 mm above or at the external oblique ridge with monocortical screws.
Altri nomi:
  • two Titanium Miniplates Fixation ,Dual Miniplate Fixation ,Conventional Two-Plate Technique.
Single 2.0 mm 9-hole 3D titanium plate fixed with monocortical screws. Plate contoured with horizontal crossbars perpendicular and vertical struts parallel to fracture line. Screws placed diagonally first.
Altri nomi:
  • Single 3D Titanium Plate, 2.0 mm Thickness, 6-Hole Rectangular 6-Hole ,3D Titanium Miniplate 3D Contoured Titanium Plate, 2.0 mm, 6-Hole

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Occlusal force
Lasso di tempo: first day surgery , second visit 30 days , the last visit 120 days. .
use bite force measurement device . make patient bite to muser the force (, newton unit).
first day surgery , second visit 30 days , the last visit 120 days. .

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
maximal incisal opening.
Lasso di tempo: first day surgery , second visit 30 days , the last visit 120 days. .

Ask the patient to open their mouth as wide as possible without feeling pain.

Using a ruler or caliper, measure the vertical distance between the incisal edge of the upper central incisor and the incisal edge of the lower central incisor

first day surgery , second visit 30 days , the last visit 120 days. .
Patient satisfaction
Lasso di tempo: first day surgery , second visit 30 days , the last visit 120 days. .
will be measured on a visual analogue scale (VAS) with zero being unsatisfied and ten being satisfied and happy .
first day surgery , second visit 30 days , the last visit 120 days. .

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 gennaio 2025

Completamento primario (Stimato)

1 giugno 2026

Completamento dello studio (Stimato)

30 novembre 2026

Date di iscrizione allo studio

Primo inviato

10 giugno 2025

Primo inviato che soddisfa i criteri di controllo qualità

1 maggio 2026

Primo Inserito (Effettivo)

8 maggio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

8 maggio 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

1 maggio 2026

Ultimo verificato

1 aprile 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • angle frcture ,Truma

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .