Clinical Evaluation of an Alarm Activated Detection System to Enable Early Intervention of Emerging Respiratory Decline With the Linshom Medical Continuous Predictive Respiratory Sensor (CPRS)
Investigators will enroll 493 patients who will undergo non-cardiac surgery, receive supplemental oxygen via face mask or nasal cannula, and will be on continuous pulse oximetry monitor in the Post Anesthesia Care Unit (PACU). Research personnel will screen and select subjects for this study. The CRA will ensure that each subject meets the enrollment criteria, and the informed consent is properly executed. Upon arrival at the PACU, each subject will be fitted with a supplemental oxygen mask or nasal cannula containing the Linshom sensor, which will be connected to Linshom Cyber G-15 monitor for data collection. A pulse oximeter will be applied to the hand (non-NIBP arm), which will be connected to a hospital monitor (SOC). The Linshom G-15 monitor will collect data every 100 milliseconds. The Linshom CPRM will automatically initiate baseline data capture. The CRA will begin recording any clinical interventions (e.g., medications and stimulation upon detection of changes in patient's condition) that are performed by the PACU staff, paying close attention to time at which those interventions occurred. Data collection will be performed throughout the subject's entire PACU stay. After data collection, the Linshom engineers will retrieve the data from all monitors and time-sync all data collected from each patient (Linshom CPRM and pulse oximetry). Manually recorded data regarding the time points at which clinical interventions were provided by the PACU staff will also be reviewed and those time points will be noted as RDEs.
The Linshom CPRM system monitors the distinct metric of RDE occurrence. Throughout a given patient's stay, nurses will be provided with two distinct cues (each cue comprised of an auditory and visual component), 1 from CPRM, 1 from SoC, alerting them to a patient's respiratory state. In addition, clinical staff will have access to a summary metrics of critical parameters and RDE occurrences on the Linshom monitor (total RDE count, time since last RDE).
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Linshom has developed the Continuous Predictive Respiratory Monitoring (CPRM) system, designed to alert clinicians of active or impending respiratory distress events. The system features a miniaturized version of the FDA cleared Linshom Continuous Predictive Respiratory Sensor - a small, wearable sensor that provides continuous real-time tracking of the critical indicators of RDE. Linshom offers an OR-quality respiratory profile at the patient bedside, which allows health care providers to promptly diagnose emerging respiratory decline and intervene with appropriate medical care. The technology is based on a novel thermal sensor which is regulated by a thermo-electric cooler utilizing a proprietary control loop process. Respiration state is measured via temperature change throughout a patients inspiratory/expiratory cycle. This delivers a respiratory signature allowing for continuous measurement of RR, rTV, rMV, SSLB, apnea detection, and I/E ratio. The CPRM system solves the unmet need for a small, portable, sensor and monitor that tracks RR, rTV, rMV, seconds since last breath (SSLB), and I:E ratio in real time and continuously. These parameters are crucial in monitoring of patients suffering from both acute and chronic respiratory illness.
The main focus will be performing an unblinded trial where the CPRM system is actively used to guide clinical intervention with the aim of reducing burden of RDEs, which will provide critical evidence of the clinical care and health economic cost benefits of the CPRM system.
Specific aim:
Conduct an unblinded clinical trial to demonstrate that Linshom CPRM + standard of care (SOC) can reduce Respiratory Depression Episodes by at least 30% compared to SOC alone.
Outcome: Demonstrate that the CPRM system can reduce the frequency and length of RDE events more effectively than SOC alone (continuous pulse oximetry and 1 on 1 nursing care) when utilized as an alert system by nursing staff.
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: James R Hughen, MBA
- Numero di telefono: 443-994-1448
- Email: rhughen@linshommedical.com
Backup dei contatti dello studio
- Nome: Ronen Feldman, BS
- Numero di telefono: 443-472-6188
- Email: rfeldman@linshommedical.com
Luoghi di studio
-
-
Maryland
-
Baltimore, Maryland, Stati Uniti, 21230
- Linshom Medical, Inc.
-
Contatto:
- James R Hughen, MBA
- Numero di telefono: 443-994-1448
- Email: rhughen@linshommedical.com
-
Contatto:
- Ronen Feldman, BS
- Numero di telefono: 443-472-6188
- Email: rfeldman@linshommedical.com
-
-
Ohio
-
Columbus, Ohio, Stati Uniti, 43210
- Ohio State University Wexner Medical Center
-
Contatto:
- Richard D Urman, MD, MBA
- Numero di telefono: 614-293-5188
- Email: richard.urman@osumc.edu
-
Contatto:
- Alberto Uribe, MD
- Numero di telefono: 614-293-3559
- Email: alberto.uribe@osumc.edu
-
Investigatore principale:
- Richard D Urman, MD, MBA
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- At least 18 years of age undergoing non-cardiac surgery
- Post-operative patients admitted to the post-anesthesia care unit (PACU) and expected to stay in the hospital for at least overnight.
- Receiving supplemental oxygen via face mask or nasal cannula in the PACU
- On continuous SpO2 saturation monitoring
- Receiving standard postoperative care
Exclusion Criteria:
- Requirement for any form of postoperative invasive ventilatory support
- Patients receiving only local or topical anesthesia
- Day/outpatient surgery
- Unable to cooperate with the application of the study device
- Surgical/nursing/anesthesia staff suggest no study-related monitoring because of medical situation
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Prevenzione
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Post surgical (non-cardiac) PACU patients with anticipated overnight stay.
The intervention will be the institutional standard of care (SOC) intervention(s) for any patient experiencing a RDE (typically an apnea ≥ 30 seconds). Typical interventions may include patient arousal, patient re-positioning, supplemental oxygen administration and other SOC. Inclusion Criteria:
Exclusion Criteria:
|
Linshom CPRM with alarms enabled will be used to alert nurses of respiratory issues.
Action will be taken based on nurse assessment and will follow standard of care procedures.
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Measure the number of Respiratory Depression Events (RDE) of Linshom CPRM + standard of care (SOC) vs. SOC alone.
Lasso di tempo: 12 months
|
Demonstrate that the CPRM system can reduce the frequency of RDE events more effectively than SOC alone (continuous pulse oximetry and 1 on 1 nursing care) when utilized as an alert system by nursing staff. The statistical test to be used is a negative binomial regression model, which is appropriate for modeling count data (RDE rates) with potential overdispersion. |
12 months
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Measure the length (in seconds) of RDE per patient with Linshom CPRM + standard of care (SOC) vs. SOC alone.
Lasso di tempo: 12 months
|
Demonstrate that the CPRM system can reduce the length of RDE events more effectively than SOC alone (continuous pulse oximetry and 1 on 1 nursing care) when utilized as an alert system by nursing staff. The statistical tests will evaluate: Mean/Median Time Per RDE. |
12 months
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Measure the Mean/Median Cumulative RDE Time Per Patient in Linshom + SOC vs. SOC alone.
Lasso di tempo: 12 months.
|
Demonstrate that Linshom Medical + SOC can reduce the Mean/Median Cumulative RDE Time Per Patient vs. SOC alone.
|
12 months.
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Investigatori
Investigatori
- Investigatore principale: Richard D Urman, MD, MBA, Ohio State University
- Direttore dello studio: Alberto Uribe, MD, Ohio State University
Pubblicazioni e link utili
Collegamenti utili
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Malattie delle vie respiratorie
- Disturbi respiratori
- Segni e sintomi, respiratori
- Condizioni patologiche, segni e sintomi
- Segni e sintomi
- Insufficienza respiratoria
- Apnea
- Tecniche investigative
- Tecniche di laboratorio clinico
- Tecniche e procedure diagnostiche
- Diagnosi
- Tecniche diagnostiche, sistema respiratorio
- Tecniche diagnostiche, cardiovascolare
- Test della funzione cardiaca
- Test della funzione respiratorio
- Analisi chimica del sangue
- Test di chimica clinica
- Analisi dei Gas Ematici
- Ossimetria
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- SB1HL182474 (Sovvenzione/contratto NIH degli Stati Uniti)
- 1SB1HL182474-01 (Sovvenzione/contratto NIH degli Stati Uniti)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .