Closed-Loop Stimulation in Left Bundle Branch Area Pacing
Closed-Loop Stimulation Combined With Left Bundle Branch Area Pacing in Patients With Atrioventricular Conduction Disorders
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Podkarpackie Voivodeship
-
Rzeszów, Podkarpackie Voivodeship, Polonia, 35-302
- Clinical Provincial Hospital No. 2 in Rzeszow
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Age ≥18 years
- Permanent atrial fibrillation
- Chronotropic incompetence
- Permanent pacemaker with left bundle branch area pacing (LBBAP)
- Ventricular pacing burden >50%
- Ability to provide written informed consent
Exclusion Criteria:
- Age <18 years
- Inability or unwillingness to provide informed consent
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione incrociata
- Mascheramento: Separare
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: CLS followed by VVIR
Participants received closed-loop stimulation (CLS) during the first study period, followed by accelerometer-based VVIR pacing during the second study period.
|
The pacemaker was programmed to closed-loop stimulation (CLS), an impedance-based rate-adaptive pacing algorithm that adjusts the pacing rate in response to changes in intracardiac impedance associated with cardiac contractile dynamics.
The pacemaker was programmed to VVIR mode with accelerometer-based rate-adaptive pacing.
The pacing rate was adjusted according to physical activity detected by the device's accelerometer.
|
|
Sperimentale: VVIR followed by CLS
Participants received accelerometer-based VVIR pacing during the first study period, followed by closed-loop stimulation (CLS) during the second study period.
|
The pacemaker was programmed to closed-loop stimulation (CLS), an impedance-based rate-adaptive pacing algorithm that adjusts the pacing rate in response to changes in intracardiac impedance associated with cardiac contractile dynamics.
The pacemaker was programmed to VVIR mode with accelerometer-based rate-adaptive pacing.
The pacing rate was adjusted according to physical activity detected by the device's accelerometer.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Change in Heart Rate During Mental Stress
Lasso di tempo: At the end of each 1-month pacing period
|
Change in heart rate (ΔHR) during the Paced Auditory Serial Addition Test (PASAT), calculated as the peak heart rate recorded during the test minus the baseline heart rate.
The outcome was assessed under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing and expressed in beats per minute (bpm).
|
At the end of each 1-month pacing period
|
|
Change in Heart Rate During Isometric Handgrip
Lasso di tempo: At the end of each 1-month pacing period
|
Change in heart rate (ΔHR) during the 5-minute isometric handgrip test performed at 30% of maximal voluntary contraction, calculated as the peak heart rate recorded during the test minus the baseline heart rate.
The outcome was assessed under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing and expressed in beats per minute (bpm).
|
At the end of each 1-month pacing period
|
|
Change in Heart Rate During Treadmill Exercise
Lasso di tempo: At the end of each 1-month pacing period
|
Change in heart rate (ΔHR) during the symptom-limited treadmill exercise test using the modified Bruce protocol, calculated as the peak heart rate achieved during exercise minus the baseline heart rate.
The outcome was assessed under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing and expressed in beats per minute (bpm).
|
At the end of each 1-month pacing period
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Exercise Duration During Treadmill Testing
Lasso di tempo: At the end of each 1-month pacing period
|
Total exercise duration during the symptom-limited treadmill exercise test performed using the modified Bruce protocol.
The outcome was assessed under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing and expressed in seconds.
|
At the end of each 1-month pacing period
|
|
Metabolic Equivalents Achieved During Treadmill Testing
Lasso di tempo: At the end of each 1-month pacing period
|
Exercise capacity during the symptom-limited treadmill exercise test using the modified Bruce protocol, expressed as metabolic equivalents (METs) achieved during the test.
The outcome was assessed under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing.
|
At the end of each 1-month pacing period
|
|
Heart Rate Score During Daily Activity
Lasso di tempo: At the end of each 1-month pacing period
|
Heart Rate Score (HRS), defined as the percentage of all sensed and paced ventricular beats occurring in the most populated 10-beats-per-minute heart rate histogram bin.
HRS was assessed from pacemaker-derived heart rate histograms under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing.
Higher HRS values indicate a more concentrated heart rate distribution and less heart rate variation across histogram bins.
The score ranges from 0% to 100%.
|
At the end of each 1-month pacing period
|
|
Health-Related Quality of Life Assessed With the EQ-5D-5L Index
Lasso di tempo: At the end of each 1-month pacing period
|
Health-related quality of life was assessed using the EuroQol 5-Dimension 5-Level (EQ-5D-5L) descriptive system.
Responses were converted to an EQ-5D-5L index value using the Polish value set.
Index values range from -0.590 to 1.000, with higher values indicating better health-related quality of life.
A value of 1 represents full health, 0 represents a health state equivalent to death, and negative values represent health states valued as worse than death.
The outcome was compared between closed-loop stimulation (CLS) and accelerometer-based VVIR pacing.
|
At the end of each 1-month pacing period
|
|
Self-Rated Health Assessed With the EQ VAS
Lasso di tempo: At the end of each 1-month pacing period
|
Self-rated health was assessed using the EuroQol Visual Analogue Scale (EQ VAS), ranging from 0 to 100, where 0 represents the worst health the participant can imagine and 100 represents the best health the participant can imagine.
The outcome was assessed under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing.
|
At the end of each 1-month pacing period
|
|
Patient-Reported Pacing-Mode Preference
Lasso di tempo: At the end of the study, after completion of both 1-month pacing periods
|
At the end of the study, participants were asked during which of the two pacing periods they experienced better overall subjective well-being, or whether they had no preference.
Responses were subsequently categorized according to the pacing mode programmed during the preferred period as preference for closed-loop stimulation (CLS), preference for accelerometer-based VVIR pacing, or no preference.
|
At the end of the study, after completion of both 1-month pacing periods
|
|
Ventricular Pacing Percentage
Lasso di tempo: At the end of each 1-month pacing period
|
Ventricular pacing percentage was obtained from pacemaker interrogation and defined as the proportion of ventricular events that were paced during each study period.
The outcome was assessed under both closed-loop stimulation (CLS) and accelerometer-based VVIR pacing and expressed as a percentage from 0% to 100%.
|
At the end of each 1-month pacing period
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 039/05/2025
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .