The Diagnostic Accuracy of the Device Under Development MULTISCOPE (MULTISCOPE)
In Vitro Pilot Study to Assess the Diagnostic Accuracy of the Device Under Development MULTISCOPE
Conventional gastrointestinal endoscopy relies on ex vivo histopathology, a process limited by diagnostic delays and high costs. The MULTISCOPE project introduces a miniaturized (2.2 mm) endoscopic device integrating advanced optical biopsy with Cold Argon Plasma (CAP) therapy. Utilizing multimodal optical fibers, the system performs label-free, high-resolution imaging via two-photon autofluorescence and second-harmonic generation.
Simultaneously, the integrated CAP technology enables targeted oncological treatment by inducing apoptosis and cell-cycle arrest with minimal collateral damage. Given that Endoscopic Submucosal Dissection (ESD) inherently provides samples containing both neoplastic and healthy margins (5-8 mm safety zone), this platform allows for precise, real-time tissue characterization. This in vitro pilot study evaluates the system's diagnostic accuracy in discriminating between healthy and neoplastic colorectal tissues.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: IVO BOSKOSKI
- Numero di telefono: +39 06 3015 6580
- Email: ivo.boskoski@policlinicogemelli.it
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Colonic or rectal neoplastic lesions resectable by endoscopic submucosal dissection (ESD)
- Age ≥ 18 years, male and female
- patients with American Society of Anesthesiologists (ASA) grades 1-3
- Signed informed consent
Exclusion Criteria:
- Severe medical comorbidities precluding endoscopy;
- Uncontrolled coagulopathy;
- Pregnancy or planned pregnancy during the period of study participation;
- Life expectancy ≤2 years, as judged by the site investigator;
- Refusal to sign the informed consent.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Patients who require endoscopy with endoscopic submucosal dissection (ESD) of the colon.
Thirty consecutive colorectal specimens resected via endoscopic submucosal dissection (ESD) will be analyzed.
Each specimen serves as an internal control, comprising both central neoplasia and healthy peripheral margins ("fried-egg" morphology).
To ensure maximum accuracy with this novel device, optical biopsies will be performed on both tissue types immediately prior to formal histopathological fixation.
ESD procedures will be conducted at the Agostino Gemelli Foundation, while optical and histopathological analyses will be centralized at the Catholic University of Rome (UCSC).
|
Protocol and Transport Colorectal ESD specimens will be resected at the Fondazione Gemelli IRCCS and immediately transported dry (without formalin) to the UCSC Pathological Anatomy Unit within 15 minutes. To ensure tissue viability, dedicated staff will coordinate the transfer directly from the endoscopy suite. Ex Vivo Analysis The MULTISCOPE device will be stationed at the UCSC facility, adjacent to the pathology lab. Upon arrival, Prof. Vincenzo Arena's team will perform multimodal fiberoptic optical biopsies on both healthy and neoplastic mucosa before proceeding with standard histopathological processing. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Diagnostic Accuracy (Area Under the ROC Curve [AUC]) of the MULTISCOPE Device for Differentiating Normal versus Neoplastic Colorectal Tissue
Lasso di tempo: At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
The diagnostic accuracy of optical biopsies performed with the two-photon microendoscope MULTISCOPE prototype will be assessed and compared against standard ex vivo histopathology (gold standard) as the reference diagnosis. Diagnostic performance will be evaluated based on the Area Under the Receiver Operating Characteristic Curve (AUC). Optimal sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals will also be calculated using the Youden Index threshold. AUC values range from 0.5 (no discrimination) to 1.0 (perfect diagnostic accuracy). |
At the time of histopathological evaluation, approximately 2 weeks after the surgical procedure.
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Tumor Cell Destruction Rate After Cold Atmospheric Plasma (CAP) Exposure
Lasso di tempo: Up to 12 months (at the end of the study).
|
The therapeutic efficacy of MULTISCOPE expressed as the proportion of treated/affected cells after CAP exposure, quantified in commercial gastrointestinal tumor organoids.
|
Up to 12 months (at the end of the study).
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: IVO BOSKOSKI, Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Neoplasie per sede
- Neoplasie
- Malattie intestinali
- Neoplasie gastrointestinali
- Neoplasie dell'apparato digerente
- Malattie dell'apparato digerente
- Malattie gastrointestinali
- Neoplasie intestinali
- Malattie del retto
- Malattie del colon
- Neoplasie colorettali
- Tecniche e procedure diagnostiche
- Diagnosi
- Procedure chirurgiche, operative
- Procedure chirurgiche minimamente invasive
- Tecniche diagnostiche, chirurgiche
- Endoscopia, gastrointestinale
- Endoscopia, sistema digestivo
- Tecniche diagnostiche, sistema digestivo
- Endoscopia
- Procedure chirurgiche del sistema digestivo
- Resezione della mucosa endoscopica
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 8118 (Fred Hutch/University of Washington Cancer Consortium)
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .