A Clinical Trial With SENS-601, Injected With SPHYNX Administration System, in the Pediatric Population Presenting With Hearing Loss Related to Pathogenic Variation(s) of GJB2 Gene (HEARCONNEX)
An Open-Label, Multicenter Phase 1/2 Study to Assess the Safety, Tolerability, and Efficacy of Intracochlear Ascending Dose Injections of SENS-601 Followed by Expansion Cohort in Pediatric Population With Hearing Loss Related to Biallelic Pathogenic Variation(s) of GJB2, As Well As to Demonstrate the Performance of the Administration System, Its Safety, Its Clinical Benefit, and Its Usability
This study intends to assess safety, tolerability, and efficacy of SENS-601, injected with SPHYNX administration system, in children between 6 months and 6 years of age, with hearing loss related to pathogenic variation(s) of GJB2 gene.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Fase 2
- Fase 1
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Lionel HOVSEPIAN
- Numero di telefono: +33(0)686 831 180
- Email: contact@sensorion-pharma.com
Luoghi di studio
-
-
-
Paris, Francia, 75015
- Reclutamento
- Hopital Necker Enfants Malades
-
Contatto:
- Centre de Recherche en Audiologie pédiatrique
- Numero di telefono: +33(0)187 892 916
- Email: rdv.crea.nck@aphp.fr
-
Investigatore principale:
- Natalie LOUNDON
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Males or females aged ≥6 months to ≤6 years.
- Congenital bilateral severe sensorineural hearing loss.
- Biallelic GJB2 variation(s).
- Documented normal cochlea and internal auditory canals.
Exclusion Criteria:
- History of chronic, acute, or major disease.
- Have been dosed in a previous gene therapy clinical study.
- Other causes or risk of hearing loss, including developmental disorders, unilateral hearing loss, chronic conductive hearing loss, malformation syndrome, syndromic hearing loss or any other cause that would impact negatively the response of hair cell function, history of therapy known as ototoxic for an extended period, or documented other causes of congenital bilateral hearing loss linked to mutations in genes other than GJB2.
- Prior or current cochlear implant in the ear to be treated with SENS-601.
- Contraindication to corticosteroid therapy and/or immunosuppressive or immunomodulatory therapy or to the planned surgery, to anesthesia or increased anesthesiologic risk.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione sequenziale
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Dose escalation - Dose Level 1
Intracochlear administration of Dose level 1 of SENS-601 in one ear, with the SPHYNX injection system |
Administration of SENS-601 with the SPHYNX injection system |
|
Sperimentale: Dose escalation - Dose Level 2
Intracochlear administration of Dose level 2 of SENS-601 in one ear, with the SPHYNX injection system |
Administration of SENS-601 with the SPHYNX injection system |
|
Sperimentale: Dose expansion group
Intracochlear administration of SENS-601 in both ears, with the SPHYNX injection system, at the dose recommended following the Dose escalation phase |
Administration of SENS-601 with the SPHYNX injection system |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Safety and tolerability of SENS-601 and SPHYNX administration system
Lasso di tempo: 5 years
|
The incidence and severity of Treatment-Emergent Adverse Events (TEAEs). The incidence and severity of Adverse Device Events, Serious Adverse Device Effects, and Device Deficiencies |
5 years
|
|
Efficacy of SENS-601 assessed by ABR
Lasso di tempo: 5 years
|
Change from baseline of hearing threshold measured by auditory brainstem response (ABR) |
5 years
|
|
Efficacy of SENS-601 assessed by PTA
Lasso di tempo: 5 years
|
Change from baseline of hearing threshold measured by pure-tone audiometry (PTA) |
5 years
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
SPHYNX Injection system performance
Lasso di tempo: Day 1
|
Incidence of successful administrations, based on user questionnaires |
Day 1
|
|
SPHYNX Injection System clinical benefit
Lasso di tempo: Day 1
|
Incidence of failed surgeries due to SPHYNX injection system, based on "SENS-601 injection form" user questionnaires |
Day 1
|
|
Usability of the administration system
Lasso di tempo: Day 1
|
Evaluation of the degree to which users were able to effectively, efficiently, and safely use the devices in their specific environments, based on "Usability assessment" user questionnaire |
Day 1
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- SENS-601-101
- 2026-525698-38-00 (Ctis)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .