Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs
Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs (A Controlled Clinical Trial)
Implant-supported prostheses have become a popular treatment option in clinical dentistry because of their long-term clinical success rates and their proven functional, biological, and mechanical advantages.
Dental implants exhibit biomechanical behavior that differs from that of natural teeth because implants lack periodontal ligaments and are in direct contact with bone. Consequently, the occlusal loads received by the implant are transferred directly to the surrounding bone structure. This relationship affects stress distribution within the implant and the peripheral bone and is considered one of the major factors determining implant success. The transfer of stress or energy between the implant and the surrounding bone is influenced by several factors, including the direction of loading and the design and material characteristics of both the implant and the restorative crown.
Soft-tissue attachment around dental implants resembles that around natural teeth, as it includes junctional epithelium and connective tissue fibers. However, some important differences exist. The connective tissue fibers surrounding implants are oriented parallel rather than perpendicular to the implant surface, and the connective tissue around implants is less vascular than that surrounding natural tooth. The formation and maturation of the peri-implant soft-tissue complex require sufficient healing time. Stable soft-tissue attachment is essential for maintaining osseointegration and protecting the underlying peri-implant bone.
Several major factors influence osseointegration, including implant material, implant design, implant surface finish, bone condition, surgical technique, and implant-loading conditions. The first three factors-implant material, macro-design, and micro-surface characteristics-are directly related to the implant itself and may vary according to the manufacturing process.
The macro-design of dental implants may vary considerably, and several aspects of implant geometry can affect treatment outcomes. The implant design should provide adequate primary stability without causing excessive trauma to the osteotomy site, which may result in bone necrosis. It should also contribute to achieving an effective seal at the implant-abutment junction to preserve the integrity of the marginal soft tissues and reduce the risk of mechanical and biological complications. Furthermore, implant design should support the preservation of marginal bone levels during the initial physiological remodeling phase.
Peak horizontal and vertical loading forces are commonly concentrated at the crestal bone level. Therefore, modifications to the implant collar and thread design have been introduced to improve stress distribution and preserve marginal bone. Microthreads at the implant collar, particularly when combined with an internal conical implant-abutment connection, may contribute to improved biomechanical behavior and better maintenance of peri-implant tissues. Surface modifications have also been introduced to enhance osseointegration. These modifications may be achieved chemically by incorporating inorganic or organic components or physically by altering the surface topography at the micrometer or nanometer level.
A dental implant restoration generally consists of three main components: the implant fixture, an abutment that facilitates the support and retention of the restoration, and the final prosthetic restoration. Provisional restorations play an important role in soft-tissue management around implants. A properly finished and polished provisional crown can help establish a healthy peri-implant soft-tissue contour and provide appropriate support for the gingival margin. The decision regarding the timing and type of provisionalization should consider the expected changes in the facial gingival margin and the need to maintain soft-tissue architecture.
Polyetheretherketone is a synthetic thermoplastic polymer characterized by high mechanical performance and has been used as a biomaterial in various medical applications. A modified form of this material, known as BioHPP, has been specifically optimized for dental applications. It is reinforced with ceramic fillers to improve its mechanical properties and make it suitable for the fabrication of crowns and fixed prostheses.
Monolithic zirconia restorations represent another treatment option. These restorations are milled from solid zirconia blocks and may be individually stained to reproduce the appearance of enamel and gingival tissues. Zirconia provides favorable esthetic properties, particularly because it eliminates the dark cervical line that may occur with metal-based restorations. It is also characterized by high strength, durability, wear resistance, and a low risk of chipping or crack formation.
The differences in the elastic modulus, rigidity, and stress-absorbing capacity of PEEK and zirconia may influence the transmission of occlusal forces to dental implants and the surround
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: kareem mohamed abdel motaleb, master degree
- Numero di telefono: 201005335831
- Email: kareemabdelmotaleb@yahoo.com
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age range of the patients from 35-50 years old
- Patients able physically and psychologically implant placement
- patients are medically free.
- Presence of teeth in opposite arch with normal occlusal relation.
- Patient with masticatory forces within the normal range
- Patient with normal muscel tone to avoid bruxer patient and it will be assessed using the electromyograph
- Supra-gingival margin after preparation.
- Patients willing to return for follow-up examinations and evaluation.
- D2 or D3 bone quality will be preferred
Exclusion Criteria:
- Smoking patients.
- Patients with poor oral hygiene and motivation.
- Patients with parafunctional habits.
- D1 and D4 bone quality will be excluded
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Comparatore attivo: first implant design
first implant design |
PEEK crown zirconia crown |
|
Sperimentale: second implant design
second implant design |
PEEK crown zirconia crown |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
crestal bone loss
Lasso di tempo: 1 year
|
Intraoral X-rays will be made using the long-cone parallel technique for the two groups. All radiographs were digitized for evaluation of the bone levels (BL) at different time points. The marginal BL was determined by measuring the distance between the implant shoulder (reference) and the most coronal bone-to implant contact. These measurements were made by two independent examiners mesially and distally of the implants and in 0.1-mm increments |
1 year
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
gingival index
Lasso di tempo: 1 year
|
Gingival index of the two groups will be assessed by the Loe & Silness gingival index as follow: Grade 0: (Normal gingival) Natural coral pink gingival. Grade 1: (Mild inflammation) Slight change in color, slight edema. No bleeding on probing. Grade 2: (Moderate inflammation) Redness, edema and glazing. Bleeding on probing. Grade 3: (Severe inflammation) Marked redness and edema. Tendency to spontaneous bleeding. Ulceration. |
1 year
|
|
probing depth
Lasso di tempo: 1 year
|
Probing pocket depth (PPD) for the two groups will be measured from the mucosal margin to the bottom of the probeable pocket in millimeters with a periodontal probe (PCB 12; Hu-Friedy, Leimen, Germany) at four aspects per implant mesial distal buccal lingual The subscales will be summed and an average will be taken. |
1 year
|
Collaboratori e investigatori
Sponsor
Sponsor
Pubblicazioni e link utili
Pubblicazioni generali
- R.M. Kamal et al. / Al-Azhar Journal of Dentistry 11 (2024) 27e31
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- serial number of 1006
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .