Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements

13 novembre 2026 aggiornato da: Nayra Mohammed Ahmed Zaki, Tanta University

Validation of Buccolingual Ridge Width Measurements on CBCT Using Direct Intraoperative Measurements in The Posterior Mandible During Implant Placement.

This study aims to validate the accuracy of cone beam computed tomography (CBCT) in assessing buccolingual ridge width at posterior mandibular implant sites by comparing CBCT-derived measurements with standardized direct intraoperative caliper measurements obtained at the planned implant position.

Panoramica dello studio

Stato

Non ancora reclutamento

Condizioni

Intervento / Trattamento

Descrizione dettagliata

The alveolar ridge is a dynamic anatomical structure that undergoes continuous remodeling throughout life in response to functional and biological changes. Following tooth extraction, progressive dimensional alterations occur in the alveolar bone, resulting in reduction of ridge height and width. Several studies have demonstrated that post-extraction bone resorption predominantly affecting the buccolingual dimension, leading to changes in ridge morphology and contour(1, 2). These dimensional changes may complicate accurate radiographic and clinical assessment of the residual alveolar ridge(3).

The success of implant therapy is influenced by several endogenous and exogenous factors. Endogenous factors include the quality and quantity of the supporting alveolar bone, whereas exogenous factors include implant length, diameter, design, and surgical technique. Bone quality varies considerably among different regions of jaws. In general, the mandible demonstrates denser cortical bone than the maxilla, while posterior regions of both jaws tend to exhibit reduced cortical thickness and increased trabecular porosity(4). Therefore, accurate assessment of alveolar bone dimensions is considered a fundamental prerequisite for proper implant planning and successful treatment outcomes(5).

The posterior mandibular region exhibits considerable anatomical variability in alveolar ridge morphology and cortical bone configuration. Buccolingual ridge width in this region may be influenced by residual ridge resorption, cortical plate thickness, and individual anatomical characteristics. In addition, the lingual aspect of the posterior mandible may present anatomical concavities that increase the complexity of ridge assessment and necessitate accurate evaluation of bone dimensions prior to the surgical procedures(6).

Accurate evaluation of buccolingual ridge dimensions is essential for reliable assessment of alveolar bone morphology. Inaccurate estimation of ridge width may result in discrepancies between radiographic findings and actual bone dimensions. Therefore, precise and reproducible measurement methods are required to ensure reliable assessment of alveolar ridge width, particularly in posterior mandibular regions where anatomical variations including lingual concavities and undercut are frequently encountered(5).

Conventional two-dimensional radiographic techniques, including panoramic and periapical radiography, have been widely used for assessment of alveolar bone. However, these imaging modalities have several limitations related to magnification, distortion, superimposition, and inability to evaluate the buccolingual dimension of the alveolar ridge. Such limitations may reduce the accuracy of linear measurements and compromise reliable assessment of bone morphology in posterior mandibular regions(7).

The inherent limitations of conventional two-dimensional imaging techniques have increased the demand for volumetric imaging modalities capable of providing accurate three-dimensional visualization of alveolar bone morphology. Three-dimensional imaging modality eliminates the superimposition and geometric distortion commonly associated with conventional radiography and enables precise multiplanar reconstruction of osseous structures in the axial, coronal, and sagittal planes(8).This capability enables more accurate assessment of the buccolingual dimension of the alveolar ridge and improves radiographic evaluation of anatomical structures in posterior mandibular regions. Consequently, volumetric imaging modalities have become increasingly important for accurate evaluation of alveolar bone dimensions and morphology(9).

Cone-beam computed tomography (CBCT) has become widely utilized in dentomaxillofacial imaging because of its ability to provide high-resolution three-dimensional images with relatively low radiation exposure compared with conventional computed tomography. CBCT enables accurate linear measurements of alveolar bone dimensions and facilitates detailed evaluation of anatomical structures relevant to implant site assessment and surgical planning(9).

Although CBCT has demonstrated high accuracy in assessment of alveolar bone dimensions, validation of CBCT-derived measurements under clinical conditions remains essential. Minor discrepancies between radiographic measurements and actual bone dimensions may still occur due to factors related to image acquisition, voxel size, observer variability, and image interpretation(10). Therefore, direct intraoperative measurements continue to be considered an important reference standard for evaluation of the accuracy and reproducibility of CBCT linear measurements(11).

Direct intraoperative measurements provide accurate assessment of alveolar bone dimensions and are considered the reference standard for validating radiographic measurements in clinical studies. The variations in measurement techniques, anatomical reference points, and imaging protocols may influence the reported accuracy of CBCT measurements. Consequently, further validation studies remain necessary to assess the reliability of CBCT measurements in anatomically variable posterior mandibular regions(12).

Although previous validation studies have reported favorable agreement between CBCT-derived measurements and direct intraoperative measurements in posterior mandibular implant sites, these studies have not employed standardized localization devices to ensure identical measurement points between the radiographic and surgical phases(12, 13). The absence of a standardized point localization method may introduce positional variability in reported measurements, potentially affecting the reliability of comparison outcomes(13). Ridge mapping by CBCT needs to be compared to what would seem to be the most accurate measurement, which is direct caliper measurement following surgical exposure of the bone(11, 14). Therefore, a validated measurement protocol incorporating a standardized stent-based localization device is required to ensure reproducible and accurate comparison between CBCT-derived and intraoperative ridge width measurements.

To the best of our knowledge, there are insufficient clinical studies that have compared CBCT-derived buccolingual ridge width measurements with direct intraoperative caliper measurements obtained at standardized levels corresponding to planned implant positions in posterior mandibular sites. Therefore, the aim of the present study is to validate the accuracy and reliability of buccolingual ridge width measurements obtained from cone-beam computed tomography (CBCT) by comparing them with direct intraoperative caliper measurements in posterior mandibular implant sites using a standardized stent-based localization protocol.

The null hypothesis of the present study is that there will be no statistically significant difference between buccolingual ridge width measurements obtained from CBCT and those obtained through direct intraoperative measurements at posterior mandibular implant sites.

Tipo di studio

Osservativo

Iscrizione (Stimato)

30

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Adults aged 18 years or older who are scheduled for single-tooth dental implant placement in the posterior mandible at a previously extracted mandibular first or second molar site. Participants must have sufficient post-extraction healing, identifiable buccolingual ridge morphology, and adequate residual alveolar bone dimensions for implant placement. Patients must be in good general health, have a stable periodontal condition without active inflammation, and meet all inclusion criteria while excluding those with conditions or factors that may interfere with implant surgery or bone healing.

Descrizione

Inclusion Criteria:

  1. Site in Patients aged 18 years or above.
  2. Patients indicated for posterior mandibular implant placement at the site of a previously extracted mandibular first or second molar.
  3. Sufficient post-extraction healing time with preservation of identifiable buccolingual ridge morphology including lingual ridge contour.
  4. Adequate residual alveolar bone dimensions to permit implant placement.
  5. Patients in good general health with no systemic conditions contraindicated for implant surgery.
  6. Patients with stable periodontal condition and no signs of active inflammation.

Exclusion Criteria:

  1. History of malignancy or head and neck radiation therapy.
  2. Uncontrolled systemic diseases contraindicated for surgical procedures.
  3. Active periodontal infection or acute inflammation at the planned implant site.
  4. History of periodontal or bone augmentation surgery at the planned site.
  5. Parafunctional occlusal habits including bruxism or clenching.
  6. Pregnant or lactating females.
  7. Patients with smoking habits that may affect bone healing.
  8. Insufficient residual alveolar bone dimensions precluding implant placement without augmentation procedures.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Modelli osservazionali: OTHER
  • Prospettive temporali: PROSPECTIVE

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Difference between CBCT-derived and direct intraoperative buccolingual ridge width
Lasso di tempo: At the time of implant placement surgery (before implant placement

Mean difference, absolute difference, and agreement between buccolingual alveolar ridge width measured on CBCT cross-sectional images and direct intraoperative caliper measurements at the standardized stent-based planned implant position. Measurements will be recorded in millimeters (mm).

At the time of implant placement surgery (before implant placement

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Interobserver and intraobserver reliability of CBCT buccolingual ridge-width measurements
Lasso di tempo: At CBCT image analysis, before implant placement surgery

reproducibility of CBCT-derived buccolingual alveolar ridge-width measurements, assessed as intraobserver and interobserver agreement between repeated measurements by two independent calibrated examiners. Measurements will be recorded in millimeters (mm)."

At CBCT image analysis, before implant placement surgery

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Investigatore principale: Dr. Malak Youssef Mohammed, professor, Faculty of Dentistry, Tanta University, Egypt

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 novembre 2026

Completamento primario (Stimato)

30 novembre 2027

Completamento dello studio (Stimato)

30 dicembre 2027

Date di iscrizione allo studio

Primo inviato

13 novembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

13 novembre 2026

Primo Inserito (Effettivo)

19 novembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

19 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

13 novembre 2026

Ultimo verificato

1 novembre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • Validation of CBCT measurement

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .