Non-Invasive Hemodynamic Assessment in Cardiogenic Shock (HD-ASSESS-CS)
Non-Invasive Hemodynamic Assessment in Cardiogenic Shock: Validation and Artificial Intelligence-Driven Innovations (HD-ASSESS-CS)
Pulmonary artery catheter (PAC) monitoring is the reference standard for hemodynamic assessment in cardiogenic shock (CS), but it is invasive, resource-demanding and not universally available. HD-ASSESS-CS is a prospective, observational, multicenter study that will enroll consecutive adult patients with CS or pre-shock in whom PAC monitoring is clinically indicated. In each patient, a standardized comprehensive transthoracic echocardiography will be performed in close temporal proximity to invasive measurements, at baseline and at repeated time points during hospitalization. The study will assess the agreement between echocardiographic and invasive hemodynamic parameters, develop novel multiparametric echocardiographic indices (strain, Doppler and cardiac time intervals), and explore artificial intelligence models for automated estimation of hemodynamics from echocardiographic images. PAC placement is not performed for research purposes and AI outputs are not used for patient care.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Patients will be enrolled at two tertiary cardiac intensive care units with established mechanical circulatory support (MCS) programs in Italy (Turin University Hospital, Turin, and San Raffaele Hospital, Milan).
For each paired assessment, values derived from the pulmonary artery catheter (PAC) and echocardiographic estimates of stroke volume, cardiac output and cardiac index, right atrial pressure, pulmonary capillary wedge pressure, pulmonary artery pressures and vascular resistances will be collected. Derived parameters will also be calculated: cardiac power output, pulmonary artery pulsatility index, right ventricular stroke work index, pulmonary arterial elastance and systemic vascular resistance. Echocardiographic and invasive measurements will be obtained independently, with each operator blinded to the other measurement.
Clinical, laboratory, treatment and MCS data will be recorded in an electronic case report form (REDCap). Echocardiographic images will be stored in DICOM format and pseudonymized at the enrolling site.
The primary analysis will use one paired echocardiography-PAC assessment per patient (Bland-Altman bias and 95% limits of agreement). Secondary analyses will include prespecified subgroups (shock etiology and severity, type of MCS, cardiac rhythm and image quality), agreement of changes over time, predictors of disagreement between echocardiography and PAC, and association with in-hospital outcomes. Exploratory deep-learning models will be trained and validated offline on pseudonymized images.
With at least 250 patients, the half-width of the 95% confidence interval around each limit of agreement will be about 0.21 standard deviations of the paired differences.
The study is funded by the Italian Ministry of Health (grant GR-2024-12378676).
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Guglielmo Gallone, MD, PhD
- Numero di telefono: +39 0116335575
- Email: guglielmo.gallone@unito.it
Luoghi di studio
-
-
Lombardy
-
Milan, Lombardy, Italia, 20132
- IRCCS Ospedale San Raffaele
-
Contatto:
- Luca Baldetti, MD
- Numero di telefono: +39 02 2643 7395
- Email: baldetti.luca@hsr.it
-
-
Piedmont
-
Turin, Piedmont, Italia, 10126
- AOU Città della Salute e della Scienza di Torino - Presidio Molinette
-
Contatto:
- Guglielmo Gallone
- Numero di telefono: +39 011 6335575
- Email: guglielmo.gallone@unito.it
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Consecutive adult patients admitted to tertiary cardiac intensive care units with cardiogenic shock or pre-shock and a clinical indication for pulmonary artery catheter monitoring.
Descrizione
Inclusion Criteria:
- Age 18 years or older
- Clinical diagnosis of cardiogenic shock or pre-shock
- Clinical indication for invasive hemodynamic monitoring with a pulmonary artery catheter according to standard of care
- Written informed consent
Exclusion Criteria:
- Refusal or inability to provide informed consent
- No clinical indication for pulmonary artery catheter monitoring
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: COHORT
- Prospettive temporali: PROSPECTIVE
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Cardiogenic shock or pre-shock with pulmonary artery catheter monitoring
Adult patients with cardiogenic shock or pre-shock in whom pulmonary artery catheter monitoring is clinically indicated, undergoing paired echocardiographic and invasive hemodynamic assessments. |
Standardized comprehensive echocardiographic hemodynamic assessment performed in close temporal proximity to pulmonary artery catheter measurements, at baseline and at predefined time points during hospitalization. No study-specific therapeutic intervention is performed. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Agreement between echocardiographic and invasive (pulmonary artery catheter-derived) hemodynamic parameters
Lasso di tempo: Baseline
|
Bias (mean difference) and 95% limits of agreement (Bland-Altman analysis) between echocardiographic estimates and pulmonary artery catheter measurements of stroke volume, cardiac output/index, right atrial pressure, pulmonary capillary wedge pressure, pulmonary artery pressures and vascular resistances. |
Baseline
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Agreement in prespecified subgroups
Lasso di tempo: Baseline
|
Bias and 95% limits of agreement between echocardiographic and invasive parameters according to shock etiology and severity, presence and type of mechanical circulatory support, cardiac rhythm and image quality. |
Baseline
|
|
Concordance of longitudinal hemodynamic changes
Lasso di tempo: From baseline up to pulmonary artery catheter removal, an average of 1 week
|
Concordance between changes over time in invasive and echocardiographic hemodynamic parameters across serial paired assessments. |
From baseline up to pulmonary artery catheter removal, an average of 1 week
|
|
Agreement of echocardiographic estimates of derived hemodynamic parameters
Lasso di tempo: Baseline
|
Bias and 95% limits of agreement for cardiac power output, pulmonary artery pulsatility index, right ventricular stroke work index, pulmonary arterial elastance and systemic vascular resistance. |
Baseline
|
|
Incremental accuracy of novel echocardiographic indices
Lasso di tempo: Baseline
|
Improvement in accuracy (coefficient of determination, mean absolute error, root mean square error, area under the receiver operating characteristic curve for clinical thresholds) of multiparametric indices based on strain, Doppler and cardiac time intervals compared with conventional echocardiographic metrics. |
Baseline
|
|
Predictors of echocardiography-pulmonary artery catheter discordance
Lasso di tempo: Baseline
|
Clinical, hemodynamic and technical factors associated with clinically relevant discordance between echocardiographic and invasive measurements (multivariable logistic regression). |
Baseline
|
|
Association of echocardiographic hemodynamic parameters with in-hospital outcomes
Lasso di tempo: From enrollment through hospital discharge, an average of 3 weeks
|
Association of echocardiographic hemodynamic parameters with in-hospital mortality, escalation or weaning of mechanical circulatory support, left ventricular assist device implantation, heart transplantation or other heart replacement strategy. |
From enrollment through hospital discharge, an average of 3 weeks
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Accuracy of artificial intelligence models for automated hemodynamic estimation
Lasso di tempo: Through study completion, an average of 3 years
|
Accuracy of deep-learning models in estimating hemodynamic parameters from echocardiographic images (mean absolute error, root mean square error, correlation with invasive values, area under the receiver operating characteristic curve for clinically relevant thresholds), using PAC measurements as reference. Models are developed offline and not used for patient care. |
Through study completion, an average of 3 years
|
Collaboratori e investigatori
Sponsor
Sponsor
Collaboratori
Collaboratori
Investigatori
Investigatori
- Investigatore principale: Guglielmo Gallone, MD, PhD, A.O.U. Città della Salute e della Scienza
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- HD-ASSESS-CS
- GR-2024-12378676 (Altro numero di sovvenzione/finanziamento: Italian Ministry of Health (Ricerca Finalizzata 2024))
- CET00152/2026 (Altro identificatore: Comitato Etico Territoriale Interaziendale AOU Citta della Salute e della Scienza di Torino)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Individual participant data are pseudonymized and subject to GDPR restrictions; aggregated data may be made available upon reasonable request to the principal investigator.
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .