このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Using Health Information Technology (HIT) to Improve Ambulatory Chronic Disease Care: Smart Device Substudy

2017年6月13日 更新者:University of Missouri-Columbia
In-home health monitoring devices have the potential to increase the speed and ease of modifying treatment for ambulatory patients living with chronic conditions. This study examines the implementation and effectiveness of remote data transmission from in-home devices (blood glucose meter/blood pressure machine) to the clinic on treatment outcomes in patients with diabetes who have out of range blood glucose (BG) or systolic blood pressure (BP) measurements. We test whether the short-term targeted use of in-home monitoring devices facilitates management for providers and improves outcome measures for patients.

調査の概要

状態

完了

詳細な説明

To evaluate the effectiveness of short-term targeted use of remote data transmission from in-home devices (blood glucose meter/blood pressure machine) to the clinic on treatment outcomes in patients with diabetes who have out of range blood glucose (BG) or systolic blood pressure (BP) measurements. Increased frequency of data transmission will provide the provider with "real time" data in order to make more timely adjustments in the treatment plan, resulting in improved glycemic control as measured by A1c values and hypertension as measured by systolic blood pressure (SBP).

Subjects will be recruited from Family & Community Medicine (FCM) and General Internal Medicine (GIM) clinics. We will randomly select patients from physicians with a minimum number of 5 eligible patients from the performance measurement list (A1c>=8% or SBP>130) to approach for the study. Patients who agree to enroll will be randomized to experimental and control using a block randomization approach stratified by age increments (18-40; 41-55; 56-70; 71+). Subjects will be randomized using prepared sealed envelopes. A total of 200 subjects (100 intervention subjects and 100 control subjects) will be enrolled over a period of one year. We will attempt to enroll equal numbers of FCM and GIM subjects.

For all subjects, baseline data will be collected from the patient, including demographic data (age, gender, race, and years of formal education), payor status (private pay, insurance, Medicaid), number of co-morbid conditions, baseline blood pressure, and length of time diagnosed with diabetes (DM) and hypertension.

Intervention patients will be instructed to test their BP and BG according to a minimum protocol of at least once daily and upload this clinical data at least every other day for the 3-month study duration, but this frequency could be further tailored by their provider, i.e., more than once daily. At least 2 of these BG readings each week should be fasting levels. Patient training will emphasize that this system is not an emergency response system, i.e., critical values should be treated in the usual manner.

Control group patients (those who do not receive the device) will be asked to test their BP and BG at least once daily (in the same fashion as the intervention group). They will be instructed to bring these readings to their clinic visits, and again at the end of the study. We will collect these readings.

Data from patients are downloaded to the website as they enter data. These data may be printed out for MD review or verbally communicated. APNs in FCM will make changes in patient treatment based on their currently established privileges, e.g., medication adjustments; RNs in GIM or FCM will review data with MDs for changes in treatment plans. All treatment changes will be individualized according to patient need, i.e., no standardized blood glucose management protocol will be employed. Communication of changes in therapy to the patient will be accomplished per usual clinic protocol, e.g., usually by a telephone call to the patient, with documentation of a telephone note in the medical record.

After three months, all subjects will return to the clinic for an A1c and BP measure, and for post study surveys. Data collection will include achievement of clinical goals in blood glucose (A1c measure at end of 3 month intervention [+/- 2 weeks] and BP). If enrolled subjects have an available A1c and BP measure recorded in the record at the end of 6 months, we will collect these data to assess longer term effects of the intervention. Patient records will be reviewed for interventions provided to patient (i.e., documenting the process of medication changes, advice provided).

Interview data will be collected from physicians and nurses re: perceptions of use of the data from the device; patient perceptions of the home-device application, and patient use rates of data upload (intervention), and frequency of BG and BP testing both before and during the intervention period (for both intervention and control patients).

The primary outcome measure will be a comparison of A1c at three months following enrollment (i.e., patient met goal of > 0.5% change in A1c or SBP < 130). The proportion of patients who meet the blood glucose / BP goal three months after enrollment will be computed for both the intervention group and the control group. For each group, the denominator will be the number of patients enrolled in that group (and thus were not meeting the recommended goals at the time of enrollment). The numerator will be those patients who meet the recommended goals as determined during an office visit which occurs three months (+/- 14 calendar days) after enrollment.

Changes in care processes will be categorized and described, and related to the patient entered data (daily blood glucose measures).

Physician and nurse perception data will be analyzed using qualitative approaches. Intervention group patient perceptions and satisfaction with the home-device application will be measured using a short survey and analyzed descriptively.

In the intervention group, patient use rates will be calculated to include the percent of readings submitted as the numerator and total expected as denominator (e.g., submitted 70 readings/90 days = 78% use rate).

RN time per week for data review & follow up will be analyzed descriptively to assess the burden of responding to monitoring data.

Data will be collected on the time for enrollment and patient training in order to estimate costs associated with the intervention.

研究の種類

介入

入学 (実際)

108

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Missouri
      • Columbia、Missouri、アメリカ、65211
        • University of Missouri, Dept. of Family and Community Medicine

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • hemoglobin A1c (A1c) ≥8% OR systolic BP> 130 on last measurement
  • on oral medication or insulin
  • Type 2 diabetes
  • Diabetes and hypertension for at least one year
  • using/owns a blood glucose meter (that is compatible with study equipment)
  • followed by an attending MD
  • private land phone line or computer with internet connection
  • enrolled at Family & Community Medicine (FCM) Green Meadows , FCM Woodrail or Fairview General Internal Medicine (GIM) clinic and anticipate receiving primary care for next 12 months from MU primary care

Exclusion Criteria:

  • newly diagnosed or Type 1 diabetes
  • legally blind
  • currently reside in a long-term care facility, including assisted living facility, residential care
  • severe cognitive impairment (6-item cognitive screen via recruitment telephone call)
  • family/household member enrolled in study

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:防止
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Home Monitoring
100 eligible subjects identified as (HbA1c >= 8% OR SBP > 130 mm Hg)
The subject will take their blood pressure or glucose measurements 1-4 times per day, depending on patient condition. They will upload these measurements using the device to a secure website at least every other day. Data will be reviewed at least 2 times per week Monday through Friday by the clinic nursing staff. Data indicating problems, e.g., critical out of range values, will be communicated to the patient's primary care physician after review by the nurse. The physician will then determine what is needed for follow up action based on the patient's condition and data (e.g., telephone call to patient home, scheduling a clinic appointment, etc).
他の名前:
  • MetrikLink, MediCompass, iMetrikus
介入なし:Usual Care
100 eligible subjects identified as (HbA1c >= 8% OR SBP > 130 mm Hg)

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
Hemoglobin A1c (HbA1c) or Systolic blood pressure (SBP)
時間枠:Baseline, 3 months
Baseline, 3 months

二次結果の測定

結果測定
時間枠
Changes in care (process), abstracted from patient's medical record
時間枠:3 months, 6 months following enrollment
3 months, 6 months following enrollment
Patient-entered device data
時間枠:All data over three months
All data over three months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:David Mehr, MD、University of Missouri, School of Medicine

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2009年5月1日

一次修了 (実際)

2010年12月1日

研究の完了 (実際)

2011年6月1日

試験登録日

最初に提出

2008年12月2日

QC基準を満たした最初の提出物

2008年12月3日

最初の投稿 (見積もり)

2008年12月4日

学習記録の更新

投稿された最後の更新 (実際)

2017年6月15日

QC基準を満たした最後の更新が送信されました

2017年6月13日

最終確認日

2017年6月1日

詳しくは

本研究に関する用語

キーワード

その他の研究ID番号

  • 1095618

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

Home monitoringの臨床試験

3
購読する