持続的外来腹膜透析における患者のセルフケアと製品欠陥報告を改善するためのチェックリスト (CLIP-SP)
Peritoneal Dialysis (PD) has been the main method of treatment for Thai End-Stage Renal Disease (ESRD) patients under the "PD First" policy of the Universal Coverage (UC) scheme. The increased demand has resulted in not only supply chain logistical problems, but also product quality concerns. Peritonitis, the main complication and checklist cause of failure in Continuous Ambulatory Peritoneal Dialysis (CAPD) patients, could be caused by a product defect. This cluster randomized trial will be conducted in 22 randomly selected PD centers in Thailand to assess if a checklist intervention could reduce peritonitis rate and increase the number of checklist product defect report.
調査の概要
詳細な説明
Peritoneal Dialysis (PD) has been the main method of treatment for Thai End-Stage Renal Disease (ESRD) patients under the "PD First" policy of the Universal Coverage (UC) scheme. The increased demand has resulted in not only supply chain logistical problems, but also product quality concerns. Peritonitis, the main complication and main cause of failure in CAPD patients, could be caused by a product defect.
PD Product Check List was developed based on the 28 routine steps of standard orientation manual for new Thai PD patients. Of these, step 2 (weighting the PD solution bag), step 3 (checking expiration date, volume, glucose concentration, clarity, and color, step 27 (weighting the PD solution bag), and step 28 (recording time, volume, and any abnormality encountered) are relevant to product defect report.
This cluster randomized trial will be conducted in 22 PD centers (anticipated 20-25 prevalent and 10-15 incidence PD cases per center) to answer the primary research question: is the checklist intervention effective in reducing peritonitis rate? The secondary research questions will also be considered: does the checklist help increase the number of product defect report?
Peritonitis incidence rate is the primary outcome, defined based on the International Society for Peritoneal Dialysis (ISPD) 2010 recommendation. Product defect incidence is the secondary outcome, measured by a number of incidence of product defect reported by the patients. Given no standard definition, a PD solution product will be considered defective if it is expired on the day of use, incorrect glucose concentration, abnormal clarity or color, physical abnormality of the box and/or the bag, or loose connector.
Because of the nature of the intervention, blinding is not possible. Cluster randomization will be performed to allocate 11 PD centers to the study group and the other 11 PD centers to control group. While all subjects will receive standard PD care, subjects in the study group will also receive the checklist plus a 30-minute orientation of how to use the checklist.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Bangkok、タイ、10330
- Faculty of Medicine, Chulalongkorn University
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- ESRD patients who start peritoneal dialysis not longer than one month and participate in PDOPPS study
Exclusion Criteria:
- ESRD patients who receive only hemodialysis
- ESRD patients who receive emergency peritoneal dialysis
- Illiterate ESRD patients or their caregivers
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:ヘルスサービス研究
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:PD Product Check List
PD Product Check List was developed based on the 28 routine steps of standard orientation manual for new Thai PD patients. Of these, step 2 (weighting the PD solution bag), step 3 (checking expiration date, volume, glucose concentration, clarity, and color, step 27 (weighting the PD solution bag), and step 28 (recording time, volume, and any abnormality encountered) are relevant to product defect report. |
PD Product Check List was developed based on the 28 routine steps of standard orientation manual for new Thai PD patients. Of these, step 2 (weighting the PD solution bag), step 3 (checking expiration date, volume, glucose concentration, clarity, and color, step 27 (weighting the PD solution bag), and step 28 (recording time, volume, and any abnormality encountered) are relevant to product defect report. |
|
介入なし:Control
Standard care |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
腹膜炎の発生率
時間枠:学習完了まで、平均1年
|
学習完了まで、平均1年
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
製品欠陥発生率
時間枠:学習完了まで、平均1年
|
学習完了まで、平均1年
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Krit Pongpirul, MD,MPH,PhD.、Chulalongkorn University
出版物と役立つリンク
一般刊行物
- Kanjanabuch T, Chancharoenthana W, Katavetin P, Sritippayawan S, Praditpornsilpa K, Ariyapitipan S, Eiam-Ong S, Dhanakijcharoen P, Lumlertgul D. The incidence of peritoneal dialysis-related infection in Thailand: a nationwide survey. J Med Assoc Thai. 2011 Sep;94 Suppl 4:S7-12.
- Dhanakijcharoen P, Sirivongs D, Aruyapitipan S, Chuengsaman P, Lumpaopong A. The "PD First" policy in Thailand: three-years experiences (2008-2011). J Med Assoc Thai. 2011 Sep;94 Suppl 4:S153-61.
- Praditpornsilpa K, Lekhyananda S, Premasathian N, Kingwatanakul P, Lumpaopong A, Gojaseni P, Sakulsaengprapha A, Prasithsirikul W, Phakdeekitcharoen B, Lelamali K, Teepprasan T, Aumanaphong C, Leerawat B, Pongpiyadej J, Srangsomvong S, Kanjanabuch T, Eiam-Ong S, Vareesaengthip K, Lumlertkul D. Prevalence trend of renal replacement therapy in Thailand: impact of health economics policy. J Med Assoc Thai. 2011 Sep;94 Suppl 4:S1-6.
- Liu FX, Gao X, Inglese G, Chuengsaman P, Pecoits-Filho R, Yu A. A Global Overview of the Impact of Peritoneal Dialysis First or Favored Policies: An Opinion. Perit Dial Int. 2015 Jul-Aug;35(4):406-20. doi: 10.3747/pdi.2013.00204. Epub 2014 Jul 31.
- Wong HS, Ong LM, Lim TO, Hooi LS, Morad Z, Ghazalli R, Shaariah W, Lim YN, Ahmad G, Goh BL, Liaw L, Pee S, Lee ML. A randomized, multicenter, open-label trial to determine peritonitis rate, product defect, and technique survival between ANDY-Disc and UltraBag in patients on CAPD. Am J Kidney Dis. 2006 Sep;48(3):464-72. doi: 10.1053/j.ajkd.2006.05.008.
- Amornnimit W, Pongpirul K, Sampatanukul P, Tungsanga K, Tosukhowong P, Kanjanabuch T. Black-stained peritoneal dialysis tubing: a national survey. Perit Dial Int. 2013 Nov-Dec;33(6):704-7. doi: 10.3747/pdi.2012.00167. No abstract available.
- Pongpirul K, Pongpirul WA, Kanjanabuch T. Potential causes of black-stained peritoneal dialysis tubing: an analysis from nurse practitioner's prospect. BMC Res Notes. 2014 Jul 6;7:434. doi: 10.1186/1756-0500-7-434.
- Treamtrakanpon W, Katavetin P, Yimsangyad K, Keawsinark P, Sanganunttakan S, Pandon S, Buddeewong D, Prakot A, Khumsupo C, Thamsutee N, Yaibuaiam R, Khumwong S, Towannang P, Theerasin Y, Mahatnan N, Eiam-Ong S, Kanjanabuch T. From the "PD First" policy to the innovation in PD care. J Med Assoc Thai. 2011 Sep;94 Suppl 4:S13-8.
- Bernardini J, Price V, Figueiredo A; International Society for Peritoneal Dialysis (ISPD) Nursing Liaison Committee. Peritoneal dialysis patient training, 2006. Perit Dial Int. 2006 Nov-Dec;26(6):625-32. No abstract available.
- Perl J, Davies SJ, Lambie M, Pisoni RL, McCullough K, Johnson DW, Sloand JA, Prichard S, Kawanishi H, Tentori F, Robinson BM. The Peritoneal Dialysis Outcomes and Practice Patterns Study (PDOPPS): Unifying Efforts to Inform Practice and Improve Global Outcomes in Peritoneal Dialysis. Perit Dial Int. 2016 May-Jun;36(3):297-307. doi: 10.3747/pdi.2014.00288. Epub 2015 Nov 2.
- Vonesh EF. Modelling peritonitis rates and associated risk factors for individuals on continuous ambulatory peritoneal dialysis. Stat Med. 1990 Mar;9(3):263-71. doi: 10.1002/sim.4780090309.
- Li PK, Szeto CC, Piraino B, Bernardini J, Figueiredo AE, Gupta A, Johnson DW, Kuijper EJ, Lye WC, Salzer W, Schaefer F, Struijk DG; International Society for Peritoneal Dialysis. Peritoneal dialysis-related infections recommendations: 2010 update. Perit Dial Int. 2010 Jul-Aug;30(4):393-423. doi: 10.3747/pdi.2010.00049. No abstract available.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (推定)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- CLIP-SP
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。