High Flow Nasal Cannula in Comparison to Apneic Oxygenation During Foreign Body Removal by Rigid Bronchoscope
調査の概要
詳細な説明
This study is a prospective, randomized controlled trial, at Ain Shams University hospitals, Cardiovascular surgery hospital (Thoracic surgery unit), Cairo, Egypt. We will include 64 patients planned for foreign body removal by rigid bronchoscope. All patients will be ASA І with recent FB aspiration in the last 72hrs either by history or documented by radiopaque shadow in chest X ray or CT scan. After achievement of anesthesia and full muscle relaxation ventilation started by open mask technique. Then the patients will be divided into two groups according to the oxygenation technique:
Group (A) (32 patients) HFNC (Vapotherm) will be used during the bronchoscopy time flow rate 50 L/min with 100% humidified oxygen and the temperature adjusted to be 38℃ .
Group (B) (32 patients) (control group) using the standard apneic oxygenation through the side port of rigid bronchoscope during the procedure
研究の種類
入学 (予想される)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:samar MD mohammed
- 電話番号:002 01006236494
- メール:dr_sm.md@hotmail.com
研究連絡先のバックアップ
- 名前:Maha MD sadek
- 電話番号:002 01144866675
- メール:mahasadek81@yahoo.com
研究場所
-
-
-
Cairo、エジプト、11511
- 募集
- Samar Mohammed
-
コンタクト:
- Maha Sadek
- 電話番号:01144866675
- メール:mahasadek81@yahoo.com
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- We will include 64 patients planned for foreign body removal by rigid bronchoscope.
- All patients will be ASA І
- Recent FB aspiration in the last 72hrs either by history or documented by radiopaque shadow in chest X ray or CT scan.
Exclusion Criteria:
- Patients age not more than 40 years old.
- Body weight less than 40 kg.
- Critically ill patients.
- Intubated patients.
- Inhalation of FB more than 72 hrs.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:支持療法
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:4倍
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Group A (High flow nasal cannula group)
(Vapotherm) will be used during the bronchoscopy time flow rate 50 L/min with 100% humidified oxygen and the temperature adjusted to be 38℃
|
flow rate 50 L/min with 100% humidified oxygen and the temperature adjusted to be 38℃
他の名前:
|
|
アクティブコンパレータ:Group B (Apeieoc oxygenation group)
The standard apneic oxygenation through the side port of rigid bronchoscope during the procedure
|
Standard apneic oxygenation through the side port of rigid bronchoscope during the procedure
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Maintain high level of oxygen saturation during the procedure
時間枠:During the procedure time
|
Monitoring oxygen saturation by pulse oximeter and recording the readings
|
During the procedure time
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (予想される)
研究の完了 (予想される)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。
Vapothermの臨床試験
-
National University Hospital, SingaporeVapotherm, Inc.まだ募集していません低酸素症 | 呼吸不全 | 高炭酸ガス血症
-
Vapotherm, Inc.VA Pittsburgh Healthcare System終了しました
-
Assiut University募集
-
Bnai Zion Medical Centerわからない
-
University of Maryland, BaltimoreVapotherm, Inc.完了
-
Fondazione IRCCS Ca' Granda, Ospedale Maggiore...Dr Anna Lavizzari; Dr Francesca Gaia Ciuffini完了