このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

従来の人工弁と凍結保存大動脈ホモグラフトを使用した感染性心内膜炎手術 (IESCOPHO)

2026年9月27日 更新者:Francesco Nappi、Centre Cardiologique du Nord

大動脈弁を含む感染性心内膜炎に対する凍結保存大動脈同種移植片対従来の人工弁:傾向スコア一致分析

: Evidence suggested that autologous or allogeneic tissue is more suitable to synthetic material in an infected field. Given the unwillingness of some surgeons to use artificial foreign materials, such as conventional mechanical or stent xenograft valve prostheses, cryopreserved aortic homografts (CAH) have been recommended revealing favorable outcomes in aortic valve endocarditis (AVE) surgery (1-5). This aspect is even more evident in cases involving prosthetic valve endocarditis (PVE) and other complex and aggressive lesions involving the aortic root and intervalvular fibrosa with abscess formation. However, most of these reports are fixed on single-arm observational studies without comparing CAH with conventional prostheses.

The key question of this study is to establish the difference in treatment failure (death, recurrent aortic valve regurgitation and reoperation), all-cause and cause-specific (cardiac vs noncardiac) mortality, hospitalizations for heart failure during follow-up (structural/non structural valve deterioration, thromboembolism and recurrent endocarditis) in patients who received the CAH vs conventional mechanical or stent xenograft valve prostheses for aortic valve replacement (AVR) secondary to infective endocarditis (IE)

調査の概要

詳細な説明

The target population enrolled in the study includes patients with aortic-valve endocarditis at risk of embolization, heart failure and uncontrolled infection undergoing AVR with the use of CAH or conventional mechanical or stent xenograft valve prostheses. Individuals were adequately treated per applicable standards, including for the treatment of infection, LV dysfunction and heart failure. Patients enrolled in the studies were NYHA functional class II, III, or outpatient NYHA IV.

Three groups of patients are included in the study. Patients who were managed with CAH, patients who received AVR with conventional stented xenograft and recipients of AVR undergoing surgery with the use of mechanical prostheses.

研究の種類

観察的

入学 (推定)

760

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • France
      • Saint-Denis、France、フランス、93200
        • Francesco Nappi

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年~90年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

確率サンプル

調査対象母集団

Adults with aortic valve endocarditis with or without infection extending to other heart structures who were symptomatic of congestive heart failure and unresponsive to medical therapy and who were eligible for surgical aortic valve replacement. The severity of AMR was assessed by transthoracic echocardiography, performed using the European Society of Echocardiography criteria.

説明

Inclusion Criteria:

  • Duke Criteria
  • Uncontrolled Infection Local abscess Large vegetation False aneurysm, Fistula, Dehiscence of PV
  • Embolism Large vegetation >10mm, persistent infection
  • Heart Failure Involvement of aortic root, intervalvular fibrosa, pulmonary edema, cardiogenic shock

Exclusion Criteria :

  • Pediatric
  • Any echocardiographic evidence of absence of IE

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 観測モデル:COHORT
  • 時間の展望:PROSPECTIVE

コホートと介入

グループ/コホート
介入・治療
Cryopreserved Aortic Homograft

Include patients who received CAH for native (NVE) or prosthetic valve endocarditis (PVE).

The CAH are implanted using miniroot procedure. For extended aortic valve infection, aortic root replacement and reconstruction of regional contiguity is the recommended approach. Complicated aortic IE may present with destruction of a large portion of the aortic annulus, annular abscess and colonization of infected foci in contiguous cardiac structures (eg. Aortic root and intervalvular fibrosa).

Use of homograft in first time aortic valve replacement for IE decreased over time (9,4% to 5,6%) and in reoperation (37,5% to 28,5%) in a report from STS database between 2005-2011 (6). Nevertheless, the homograft was used more often in reoperations than in primary interventions (32.2% vs 7.0%, p < 0.0001) in both valve replacements (14,6%) and for root replacements (53,2%) (6).

CAH is used for aortic root reconstruction and for repair of mitro-aortic curtain (emicommando procedure) and it is inserted as miniroot . In cases of PVE the infected prosthesis is removed with aggressive debridement of all infected and necrotic tissue. (7)The coronary ostia are prepared for reconstruction of aortic root. In complex valve endocarditis involving aortic and mitral valve a double homograft may be used.Mitro-aortic endocarditis intervalvular fibrosa is largely involved.The abscess cavity is precisely bounded and debrided. and a double homograft is used for the reconstruction (commando procedure

他の名前:
  • ルート交換
  • コマンド手順
  • エミコマンド手順

The insertion of stented/non stented xenograft may be performed using separate or continuos stich with or without teflon pledget. Biological valves may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic bioroot using bioprosthetic valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience

他の名前:
  • ルート交換
  • コマンド手順
  • エミコマンド手順

The insertion of conventional mechanical valves may be performed using separate or continuos stich with or without teflon pledget. Mechanical prostheses may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic valved conduit with a mechanical valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience

他の名前:
  • ルート交換
  • コマンド手順
Stented/Non stented xenograft

Stented/Non stented xenograft may be inserted using separate or continuos stich with or without teflon pledget. The use of biological valves increased from 57% to 67% for primary the operation during which the use of mechanical valves decreased from 30% to 24%. For reoperations, the use of biologic valves increased from 38% to 52% compared to the warning use of mechanical valves from 20% to 17%. A homograft was used in only 2.5% of valve replacements, while a biological valve was used in 68.7% of the cases. This trend is reversed both in NVE and PVE the aortic root was involved (6). In the presence of peri-annular abscess formation and mitro-aortic discontinuity, conventional stented /non stented xenograft are used in combination with synthetic patch for both NVE and PVE.

CAH is used for aortic root reconstruction and for repair of mitro-aortic curtain (emicommando procedure) and it is inserted as miniroot . In cases of PVE the infected prosthesis is removed with aggressive debridement of all infected and necrotic tissue. (7)The coronary ostia are prepared for reconstruction of aortic root. In complex valve endocarditis involving aortic and mitral valve a double homograft may be used.Mitro-aortic endocarditis intervalvular fibrosa is largely involved.The abscess cavity is precisely bounded and debrided. and a double homograft is used for the reconstruction (commando procedure

他の名前:
  • ルート交換
  • コマンド手順
  • エミコマンド手順

The insertion of stented/non stented xenograft may be performed using separate or continuos stich with or without teflon pledget. Biological valves may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic bioroot using bioprosthetic valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience

他の名前:
  • ルート交換
  • コマンド手順
  • エミコマンド手順

The insertion of conventional mechanical valves may be performed using separate or continuos stich with or without teflon pledget. Mechanical prostheses may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic valved conduit with a mechanical valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience

他の名前:
  • ルート交換
  • コマンド手順
Mechanical valve prostheses

Mechanical prostheses may be inserted using separate or continuos stich with or without teflon pledget. Prior to 2000, mechanical valves were used in 50% of patients compared to 14% since 2009. Analysis of the STS Database (6) showed that from 2005 to 2011 a progressive shift in favour of biological valves both as the primary operation (NVE) (73%) and in the reoperation (PVE) (27%) compared to mechanical prosthesis. For extended aortic valve infection, aortic root replacement and reconstruction of regional contiguity is the recommended approach. Complicated aortic IE may present with destruction of a large portion of the aortic annulus, annular abscess and colonization of infected foci in contiguous cardiac structures (eg. aortic root and intervalvular fibrosa). In the presence of peri-annular abscess formation and mitro-aortic discontinuity, conventional mechanical prostheses are used in combination with synthetic patch for both NVE and PVE

CAH is used for aortic root reconstruction and for repair of mitro-aortic curtain (emicommando procedure) and it is inserted as miniroot . In cases of PVE the infected prosthesis is removed with aggressive debridement of all infected and necrotic tissue. (7)The coronary ostia are prepared for reconstruction of aortic root. In complex valve endocarditis involving aortic and mitral valve a double homograft may be used.Mitro-aortic endocarditis intervalvular fibrosa is largely involved.The abscess cavity is precisely bounded and debrided. and a double homograft is used for the reconstruction (commando procedure

他の名前:
  • ルート交換
  • コマンド手順
  • エミコマンド手順

The insertion of stented/non stented xenograft may be performed using separate or continuos stich with or without teflon pledget. Biological valves may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic bioroot using bioprosthetic valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience

他の名前:
  • ルート交換
  • コマンド手順
  • エミコマンド手順

The insertion of conventional mechanical valves may be performed using separate or continuos stich with or without teflon pledget. Mechanical prostheses may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic valved conduit with a mechanical valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience

他の名前:
  • ルート交換
  • コマンド手順

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Treatment failure
時間枠:10 years]

The primary end point of the study is the degree of treatment failure as assessed by death, recurrent aortic valve regurgitation and reoperation

10 years]

二次結果の測定

結果測定
メジャーの説明
時間枠
Overall Mortality
時間枠:10 years

The secondary endpoint of the study is the evaluation of overall mortality

10 years
Cardiac Death
時間枠:10 years

The secondary endpoint of the study is the evaluation of cardiac death

10 years
Non Cardiac Death
時間枠:10 years

The secondary endpoint of the study is the evaluation of non cardiac death

10 years
Hospitalizations for Heart Failure (HF)
時間枠:10 years

The secondary endpoint of the study is the evaluation of hospedalization rates for heart failure valve due to structural/non structural valve deterioration, thromboembolism and recurrent endocarditis

10 years
Major Adverse Cardiac or Cerebrovascular Events (MACCE)
時間枠:10 years

Composite of major adverse cardiac or cerebrovascular events (rate of death, stroke, subsequent mitral valve surgery, hospitalization for heart failure, or an increase in New York Heart Association class higher than one), serious adverse events, recurrent aortic regurgitation, quality of life, and rehospitalization.

10 years
Echocardiographic Parameter Changes (LVEF)
時間枠:10 years

Changes from baseline parameters including left ventricular ejection fraction

10 years
Echocardiographic Parameter Changes (recurrence)
時間枠:10 years

Recurrent moderate-to-severe aortic regurgitation after intervention

10 years
Echocardiographic Parameter Changes (LVEDD)
時間枠:10 years

Changes from baseline Left Ventricular End Diastolic Diameter

10 years
Echocardiographic Parameter Changes (Aortic Root diameter)
時間枠:10 years

Changes from baseline aortic root diameter

10 years

その他の成果指標

結果測定
メジャーの説明
時間枠
Treatment failure
時間枠:10 years

The primary end point of the study is the degree of treatment failure as assessed by death, recurrent aortic valve regurgitation and reoperation

10 years
A comparison of the incidence of reinfection in allogeneic substitutes and xenograft bioprostheses
時間枠:10 years

New tracers may improve diagnostic accuracy, especially for high-risk patients.¹ Antibiotics target bacteria, making them excellent candidates for molecular imaging. The aim of this study is to identify new, selective radiopharmaceuticals for PET and SPECT applications.

10 years
To assess the occurrence of reinfection in allogeneic substitutes and mechanical prostheses.
時間枠:10 years

A model was used to predict how a tracer would move across a tissue sample. The model included several types of movement, like convection, diffusion, binding to bacteria, and vascular washout. The model also included spatial variations in bacterial density, tissue permeability, and perfusion to estimate how much of the tracer would penetrate the tissue, how much would be retained, and how much would be in the background. The effects of diffusion, binding affinity, and clearance on the predicted tracer distribution were evaluated.

10 years

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Francesco Nappi, MD、Centre Cardiologique du Nord

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2005年1月1日

一次修了 (推定)

2027年3月30日

研究の完了 (推定)

2028年12月1日

試験登録日

最初に提出

2022年2月14日

QC基準を満たした最初の提出物

2022年2月14日

最初の投稿 (実際)

2022年2月23日

学習記録の更新

投稿された最後の更新 (実際)

2026年9月30日

QC基準を満たした最後の更新が送信されました

2026年9月27日

最終確認日

2026年9月1日

詳しくは

本研究に関する用語

追加の関連 MeSH 用語

その他の研究ID番号

  • CN-21-24

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する