- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT05253469
Cirugía de endocarditis infecciosa con válvulas protésicas convencionales versus homoinjerto aórtico criopreservado (IESCOPHO)
Homoinjerto aórtico criopreservado frente a válvulas protésicas convencionales para la endocarditis infecciosa que afecta a la válvula aórtica: un análisis emparejado por puntaje de propensión
: Evidence suggested that autologous or allogeneic tissue is more suitable to synthetic material in an infected field. Given the unwillingness of some surgeons to use artificial foreign materials, such as conventional mechanical or stent xenograft valve prostheses, cryopreserved aortic homografts (CAH) have been recommended revealing favorable outcomes in aortic valve endocarditis (AVE) surgery (1-5). This aspect is even more evident in cases involving prosthetic valve endocarditis (PVE) and other complex and aggressive lesions involving the aortic root and intervalvular fibrosa with abscess formation. However, most of these reports are fixed on single-arm observational studies without comparing CAH with conventional prostheses.
The key question of this study is to establish the difference in treatment failure (death, recurrent aortic valve regurgitation and reoperation), all-cause and cause-specific (cardiac vs noncardiac) mortality, hospitalizations for heart failure during follow-up (structural/non structural valve deterioration, thromboembolism and recurrent endocarditis) in patients who received the CAH vs conventional mechanical or stent xenograft valve prostheses for aortic valve replacement (AVR) secondary to infective endocarditis (IE)
Descripción general del estudio
Estado
Condiciones
Descripción detallada
The target population enrolled in the study includes patients with aortic-valve endocarditis at risk of embolization, heart failure and uncontrolled infection undergoing AVR with the use of CAH or conventional mechanical or stent xenograft valve prostheses. Individuals were adequately treated per applicable standards, including for the treatment of infection, LV dysfunction and heart failure. Patients enrolled in the studies were NYHA functional class II, III, or outpatient NYHA IV.
Three groups of patients are included in the study. Patients who were managed with CAH, patients who received AVR with conventional stented xenograft and recipients of AVR undergoing surgery with the use of mechanical prostheses.
Tipo de estudio
Inscripción (Estimado)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
France
-
Saint-Denis, France, Francia, 93200
- Francesco Nappi
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Adults with aortic valve endocarditis with or without infection extending to other heart structures who were symptomatic of congestive heart failure and unresponsive to medical therapy and who were eligible for surgical aortic valve replacement. The severity of AMR was assessed by transthoracic echocardiography, performed using the European Society of Echocardiography criteria.
Descripción
Inclusion Criteria:
- Duke Criteria
- Uncontrolled Infection Local abscess Large vegetation False aneurysm, Fistula, Dehiscence of PV
- Embolism Large vegetation >10mm, persistent infection
- Heart Failure Involvement of aortic root, intervalvular fibrosa, pulmonary edema, cardiogenic shock
Exclusion Criteria :
- Pediatric
- Any echocardiographic evidence of absence of IE
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: COHORT
- Perspectivas temporales: PROSPECTIVE
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
Cryopreserved Aortic Homograft
Include patients who received CAH for native (NVE) or prosthetic valve endocarditis (PVE). The CAH are implanted using miniroot procedure. For extended aortic valve infection, aortic root replacement and reconstruction of regional contiguity is the recommended approach. Complicated aortic IE may present with destruction of a large portion of the aortic annulus, annular abscess and colonization of infected foci in contiguous cardiac structures (eg. Aortic root and intervalvular fibrosa). Use of homograft in first time aortic valve replacement for IE decreased over time (9,4% to 5,6%) and in reoperation (37,5% to 28,5%) in a report from STS database between 2005-2011 (6). Nevertheless, the homograft was used more often in reoperations than in primary interventions (32.2% vs 7.0%, p < 0.0001) in both valve replacements (14,6%) and for root replacements (53,2%) (6). |
CAH is used for aortic root reconstruction and for repair of mitro-aortic curtain (emicommando procedure) and it is inserted as miniroot . In cases of PVE the infected prosthesis is removed with aggressive debridement of all infected and necrotic tissue. (7)The coronary ostia are prepared for reconstruction of aortic root. In complex valve endocarditis involving aortic and mitral valve a double homograft may be used.Mitro-aortic endocarditis intervalvular fibrosa is largely involved.The abscess cavity is precisely bounded and debrided. and a double homograft is used for the reconstruction (commando procedure
Otros nombres:
The insertion of stented/non stented xenograft may be performed using separate or continuos stich with or without teflon pledget. Biological valves may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic bioroot using bioprosthetic valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience
Otros nombres:
The insertion of conventional mechanical valves may be performed using separate or continuos stich with or without teflon pledget. Mechanical prostheses may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic valved conduit with a mechanical valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience
Otros nombres:
|
|
Stented/Non stented xenograft
Stented/Non stented xenograft may be inserted using separate or continuos stich with or without teflon pledget. The use of biological valves increased from 57% to 67% for primary the operation during which the use of mechanical valves decreased from 30% to 24%. For reoperations, the use of biologic valves increased from 38% to 52% compared to the warning use of mechanical valves from 20% to 17%. A homograft was used in only 2.5% of valve replacements, while a biological valve was used in 68.7% of the cases. This trend is reversed both in NVE and PVE the aortic root was involved (6). In the presence of peri-annular abscess formation and mitro-aortic discontinuity, conventional stented /non stented xenograft are used in combination with synthetic patch for both NVE and PVE. |
CAH is used for aortic root reconstruction and for repair of mitro-aortic curtain (emicommando procedure) and it is inserted as miniroot . In cases of PVE the infected prosthesis is removed with aggressive debridement of all infected and necrotic tissue. (7)The coronary ostia are prepared for reconstruction of aortic root. In complex valve endocarditis involving aortic and mitral valve a double homograft may be used.Mitro-aortic endocarditis intervalvular fibrosa is largely involved.The abscess cavity is precisely bounded and debrided. and a double homograft is used for the reconstruction (commando procedure
Otros nombres:
The insertion of stented/non stented xenograft may be performed using separate or continuos stich with or without teflon pledget. Biological valves may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic bioroot using bioprosthetic valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience
Otros nombres:
The insertion of conventional mechanical valves may be performed using separate or continuos stich with or without teflon pledget. Mechanical prostheses may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic valved conduit with a mechanical valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience
Otros nombres:
|
|
Mechanical valve prostheses
Mechanical prostheses may be inserted using separate or continuos stich with or without teflon pledget. Prior to 2000, mechanical valves were used in 50% of patients compared to 14% since 2009. Analysis of the STS Database (6) showed that from 2005 to 2011 a progressive shift in favour of biological valves both as the primary operation (NVE) (73%) and in the reoperation (PVE) (27%) compared to mechanical prosthesis. For extended aortic valve infection, aortic root replacement and reconstruction of regional contiguity is the recommended approach. Complicated aortic IE may present with destruction of a large portion of the aortic annulus, annular abscess and colonization of infected foci in contiguous cardiac structures (eg. aortic root and intervalvular fibrosa). In the presence of peri-annular abscess formation and mitro-aortic discontinuity, conventional mechanical prostheses are used in combination with synthetic patch for both NVE and PVE |
CAH is used for aortic root reconstruction and for repair of mitro-aortic curtain (emicommando procedure) and it is inserted as miniroot . In cases of PVE the infected prosthesis is removed with aggressive debridement of all infected and necrotic tissue. (7)The coronary ostia are prepared for reconstruction of aortic root. In complex valve endocarditis involving aortic and mitral valve a double homograft may be used.Mitro-aortic endocarditis intervalvular fibrosa is largely involved.The abscess cavity is precisely bounded and debrided. and a double homograft is used for the reconstruction (commando procedure
Otros nombres:
The insertion of stented/non stented xenograft may be performed using separate or continuos stich with or without teflon pledget. Biological valves may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic bioroot using bioprosthetic valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience
Otros nombres:
The insertion of conventional mechanical valves may be performed using separate or continuos stich with or without teflon pledget. Mechanical prostheses may be implated alone or combined with polyester or pericardial patch when reconstruction of annulus is required. In cases of aggressive lesions requiring root and /or intervalvular fibrosa reconstruction the choice of prosthetic valved conduit with a mechanical valve is considered acceptable alternatives to CAH although it should be guided by the surgeon's experience
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Treatment failure
Periodo de tiempo: 10 years]
|
The primary end point of the study is the degree of treatment failure as assessed by death, recurrent aortic valve regurgitation and reoperation |
10 years]
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Overall Mortality
Periodo de tiempo: 10 years
|
The secondary endpoint of the study is the evaluation of overall mortality |
10 years
|
|
Cardiac Death
Periodo de tiempo: 10 years
|
The secondary endpoint of the study is the evaluation of cardiac death |
10 years
|
|
Non Cardiac Death
Periodo de tiempo: 10 years
|
The secondary endpoint of the study is the evaluation of non cardiac death |
10 years
|
|
Hospitalizations for Heart Failure (HF)
Periodo de tiempo: 10 years
|
The secondary endpoint of the study is the evaluation of hospedalization rates for heart failure valve due to structural/non structural valve deterioration, thromboembolism and recurrent endocarditis |
10 years
|
|
Major Adverse Cardiac or Cerebrovascular Events (MACCE)
Periodo de tiempo: 10 years
|
Composite of major adverse cardiac or cerebrovascular events (rate of death, stroke, subsequent mitral valve surgery, hospitalization for heart failure, or an increase in New York Heart Association class higher than one), serious adverse events, recurrent aortic regurgitation, quality of life, and rehospitalization. |
10 years
|
|
Echocardiographic Parameter Changes (LVEF)
Periodo de tiempo: 10 years
|
Changes from baseline parameters including left ventricular ejection fraction |
10 years
|
|
Echocardiographic Parameter Changes (recurrence)
Periodo de tiempo: 10 years
|
Recurrent moderate-to-severe aortic regurgitation after intervention |
10 years
|
|
Echocardiographic Parameter Changes (LVEDD)
Periodo de tiempo: 10 years
|
Changes from baseline Left Ventricular End Diastolic Diameter |
10 years
|
|
Echocardiographic Parameter Changes (Aortic Root diameter)
Periodo de tiempo: 10 years
|
Changes from baseline aortic root diameter |
10 years
|
Otras medidas de resultado
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Treatment failure
Periodo de tiempo: 10 years
|
The primary end point of the study is the degree of treatment failure as assessed by death, recurrent aortic valve regurgitation and reoperation |
10 years
|
|
A comparison of the incidence of reinfection in allogeneic substitutes and xenograft bioprostheses
Periodo de tiempo: 10 years
|
New tracers may improve diagnostic accuracy, especially for high-risk patients.¹ Antibiotics target bacteria, making them excellent candidates for molecular imaging. The aim of this study is to identify new, selective radiopharmaceuticals for PET and SPECT applications. |
10 years
|
|
To assess the occurrence of reinfection in allogeneic substitutes and mechanical prostheses.
Periodo de tiempo: 10 years
|
A model was used to predict how a tracer would move across a tissue sample. The model included several types of movement, like convection, diffusion, binding to bacteria, and vascular washout. The model also included spatial variations in bacterial density, tissue permeability, and perfusion to estimate how much of the tracer would penetrate the tissue, how much would be retained, and how much would be in the background. The effects of diffusion, binding affinity, and clearance on the predicted tracer distribution were evaluated. |
10 years
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Francesco Nappi, MD, Centre Cardiologique du Nord
Publicaciones y enlaces útiles
Publicaciones Generales
- Nappi F, Nenna A, Petitti T, Spadaccio C, Gambardella I, Lusini M, Chello M, Acar C. Long-term outcome of cryopreserved allograft for aortic valve replacement. J Thorac Cardiovasc Surg. 2018 Oct;156(4):1357-1365.e6. doi: 10.1016/j.jtcvs.2018.04.040. Epub 2018 Apr 18.
- Olivito S, Lalande S, Nappi F, Hammoudi N, D'Alessandro C, Fouret P, Acar C. Structural deterioration of the cryopreserved mitral homograft valve. J Thorac Cardiovasc Surg. 2012 Aug;144(2):313-20, 320.e1. doi: 10.1016/j.jtcvs.2011.06.041. Epub 2011 Sep 8.
- Nappi F, Spadaccio C, Dreyfus J, Attias D, Acar C, Bando K. Mitral endocarditis: A new management framework. J Thorac Cardiovasc Surg. 2018 Oct;156(4):1486-1495.e4. doi: 10.1016/j.jtcvs.2018.03.159. Epub 2018 Apr 13. No abstract available.
- Nappi F, Spadaccio C, Acar C. Use of allogeneic tissue to treat infective valvular disease: Has everything been said? J Thorac Cardiovasc Surg. 2017 Apr;153(4):824-828. doi: 10.1016/j.jtcvs.2016.09.071. Epub 2016 Oct 24. No abstract available.
- Kim JB, Ejiofor JI, Yammine M, Camuso JM, Walsh CW, Ando M, Melnitchouk SI, Rawn JD, Leacche M, MacGillivray TE, Cohn LH, Byrne JG, Sundt TM. Are homografts superior to conventional prosthetic valves in the setting of infective endocarditis involving the aortic valve? J Thorac Cardiovasc Surg. 2016 May;151(5):1239-46, 1248.e1-2. doi: 10.1016/j.jtcvs.2015.12.061. Epub 2016 Jan 23.
- Sabik JF, Lytle BW, Blackstone EH, Marullo AG, Pettersson GB, Cosgrove DM. Aortic root replacement with cryopreserved allograft for prosthetic valve endocarditis. Ann Thorac Surg. 2002 Sep;74(3):650-9; discussion 659. doi: 10.1016/s0003-4975(02)03779-7.
- Savage EB, Saha-Chaudhuri P, Asher CR, Brennan JM, Gammie JS. Outcomes and prosthesis choice for active aortic valve infective endocarditis: analysis of the Society of Thoracic Surgeons Adult Cardiac Surgery Database. Ann Thorac Surg. 2014 Sep;98(3):806-14. doi: 10.1016/j.athoracsur.2014.05.010. Epub 2014 Jul 29.
- Nappi F, Asta L, Garufi L, Avtaar Singh SS, Benedetto U, Acar C, Fiore A. Infective endocarditis surgery using conventional prosthetic valves versus homograft: the IESCOPO study protocol. J Cardiothorac Surg. 2026 Apr 30;21(1):432. doi: 10.1186/s13019-026-04088-8.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- CN-21-24
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .