フローダイバーターステントの国際登録 (IRF) (IRF)
頭蓋内動脈瘤治療におけるフローダイバーターの成果 - フローダイバーター ステントの国際登録 (IRF)
This multicenter retrospective cohort study aims to evaluate and compare the technical performance, safety, and clinical outcomes of intracranial aneurysms treated with flow diverter stents and endosaccular flow disruptors.
調査の概要
状態
条件
詳細な説明
Flow diverters and endosaccular flow disruptors used for the treatment of intracranial aneurysms exhibit distinct procedural and clinical outcomes, with potential differences in device-specific parameters such as procedure time, radiation exposure, adjunct device requirements, and long-term angiographic success. Since the completion of the Pipeline Embolization Device (PED) for the Intracranial Treatment of Aneurysms trial, the field of flow diversion has undergone continuous evolution with the development and approval of several devices. While these devices share a similar mechanism for aneurysm occlusion, their design and delivery systems can vary significantly. Various studies have demonstrated a promising safety and efficacy profile; however, the available data for a direct comparison of the technical and clinical outcomes between these devices remains limited.
The following collaborator is also involved in the research:
Name: Muhammed Amir Essibayi Email: m.amir.essibayi@gmail.com
研究の種類
入学 (推定)
連絡先と場所
研究連絡先
- 名前:Muhammed Amir Essibayi, MD
- 電話番号:347-908-1889
- メール:Muhammedamir.essibayi@einsteinmed.edu
研究場所
-
-
Florida
-
Coral Gables、Florida、アメリカ、33146
- 募集
- University of Miami
-
コンタクト:
- Robert M Starke, MD, MS
- 電話番号:305-355-1101
- メール:RStarke@med.miami.edu
-
主任研究者:
- Robert M Starke, MD, MS
-
Jacksonville、Florida、アメリカ、32224
- 完了
- Mayo Clinic Florida
-
Sarasota、Florida、アメリカ、34239
- 完了
- Sarasota Memorial Research Institute
-
-
Massachusetts
-
Burlington、Massachusetts、アメリカ、01805
- 募集
- Lahey Hospital and Medical Center
-
コンタクト:
- Timo Krings, MD, PhD, MSc
- 電話番号:781-744-3330
- メール:Timo.Krings@lahey.org
-
主任研究者:
- Timo Krings, MD, PhD, MSc
-
-
Michigan
-
Traverse City、Michigan、アメリカ、49684
- 募集
- Munson Medical Center
-
コンタクト:
- Amy Peterson, PhD
- 電話番号:231-935-6746
- メール:apeterson4@mhc.net
-
-
Minnesota
-
Minneapolis、Minnesota、アメリカ、55404
- 募集
- Allina Health
-
コンタクト:
- Collin M Torok, MD
- 電話番号:612-863-0376
- メール:collin.torok@allina.com
-
コンタクト:
- Marie Meyer, MA
- メール:marie.meyer@allina.com
-
主任研究者:
- Collin M Torok, MD
-
-
New Jersey
-
New Brunswick、New Jersey、アメリカ、08901
- 募集
- Robert Wood Johnson University
-
主任研究者:
- Gaurav Gupta, MD
-
コンタクト:
- Gaurav Gupta, MD
- 電話番号:732-235-6333
- メール:guptaga@rwjms.rutgers.edu
-
-
New York
-
Buffalo、New York、アメリカ、14068
- 完了
- University at Buffalo
-
The Bronx、New York、アメリカ、10467
- 募集
- Montefiore Medical Center Department of Neurosurgery
-
主任研究者:
- David Altschul, MD
-
コンタクト:
- Muhammed Amir Essibayi, MD
- 電話番号:347-908-1889
- メール:Muhammedamir.essibayi@einsteinmed.edu
-
コンタクト:
- David Altschul, MD
- 電話番号:(718) 920-7498
- メール:daltschu@montefiore.org
-
-
Pennsylvania
-
Danville、Pennsylvania、アメリカ、17822
- 完了
- Geisinger Health
-
-
Texas
-
Kingwood、Texas、アメリカ、77339
- 完了
- HCA Houston Healthcare Kingwood
-
-
-
-
Ontario
-
Toronto、Ontario、カナダ、M5B 1W8
- 募集
- St. Michael's Hospital
-
主任研究者:
- Vitor Mendes Pereira, MD
-
コンタクト:
- Vitor Mendes Pereira, MD
- 電話番号:416-864-5131
- メール:PereiraReferrals@unityhealth.to
-
コンタクト:
- Eileen Liu, MSc
- メール:eileen.liu@unityhealth.to
-
Toronto、Ontario、カナダ、M5T 2S8
- 募集
- Toronto Western Hospital
-
コンタクト:
- Pascal Mosimann, MD, PD
- 電話番号:416-603 5800
- メール:pascal.mosimann@uhn.ca
-
主任研究者:
- Pascal Mosimann, MD, PD
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Patients with intracranial aneurysms who underwent endovascular treatment with flow diverter stents or endosaccular flow disruptors
説明
Inclusion Criteria:
-
Consecutive adult patients (18 years of age or older)
-
Underwent endovascular treatment with one of the following devices:
a. Endoluminal Flow Diverter Stents: i. Pipeline Flex (Covidien, California, USA) ii. Pipeline Flex with Shield Technology (Covidien) iii. Surpass Streamline (Stryker Neurovascular, California, USA) iv. Surpass Evolve (Stryker) v. Silk flow diverter (Balt Extrusion, Montmorency, France) vi. Flow-Redirection Intraluminal Device (FRED; MicroVention) vii. Flow-Redirection Intraluminal Device X (FRED X; MicroVention) viii. p64 Flow Modulation Device (phenox GmbH) ix. Endovascular clip system (eCLIPs) (eCLIPsTM, eVasc Neurovascular, Vancouver, BC, Canada)
b. Intrasaccular Flow Disruptors: i. Woven EndoBridge (WEB; MicroVention) ii. Luna/Artisse System (Medtronic) iii. Medina Embolic Device (Medtronic) iv. Contour Neurovascular System (Cerus Endovascular) v. Neqstent Coil Assisted Flow Diverter (Cerus Endovascular) vi. pCONus and pCANvas (phenox GmbH) vii. Nexus Aneurysm Embolization System (EndoStream Medical) viii. CITADEL™ Embolization Device (Balt, USA)
-
Complete medical records and follow-up data available
Exclusion Criteria:
- Incomplete procedural or follow-up records
- Non-flow-diverter or non-flow-disruptor treatments (e.g., coiling-only cases)
- Aneurysms treated with investigational devices not listed within Inclusion Criteria
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:COHORT
- 時間の展望:RETROSPECTIVE
コホートと介入
グループ/コホート |
|---|
|
Endoluminal Flow Diverter Stent
Adults with intracranial aneurysms treated with an endoluminal flow diverter stent as part of routine care. |
|
Intrasaccular Flow Disruptor
Adults with intracranial aneurysms treated with an intrasaccular flow disruptor as part of routine care. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Technical Success
時間枠:Periprocedurally, up to 24 hours
|
Technical Success will be determined by successful deployment of the flow diverter stent or endosaccular flow disruptors. A dichotomous determination (i.e., Yes/No) will be made and summarized for this study. |
Periprocedurally, up to 24 hours
|
|
Procedural Complications following placement
時間枠:From the time of the procedure up to 1 month post treatment
|
Procedural complications will be identified as the number of instances of the following adverse clinical events: In-stent Thrombosis/Stenosis; Ischemic complications (Transient Ischemic Attack/Stroke), Intracerebral hemorrhage, Aneurysm rupture, and Vessel occlusion due to flow diverter stent or endosaccular flow disruptor placement. |
From the time of the procedure up to 1 month post treatment
|
|
Clinical Outcomes at Discharge
時間枠:Upon study discharge, up to 4 weeks
|
Clinical outcomes at discharge will be assessed using the modified Rankin Scale (mRS) for neurologic disability. The mRS is a 6-point disability scale with possible scores ranging from 0-5. mRS measures the degree of disability or dependence in the daily activities of people who have suffered a stroke or other causes of neurological disability. Higher scores are generally associated with less favorable outcomes. For this study patients with an mRS score of 0-2 will be determined to have had a "favorable" outcome to the procedure and patients with an mRS score of 3-5 will have been determined to have had an "unfavorable" outcome. |
Upon study discharge, up to 4 weeks
|
|
Clinical Outcomes at last available Follow-up
時間枠:Up to 24 months post procedure
|
Clinical outcomes at last available follow-up will be assessed using a variant of the modified Rankin Scale (mRS) for neurologic disability. The classic mRS is a 6-point disability scale with possible scores ranging from 0-5. mRS measures the degree of disability or dependence in the daily activities of people who have suffered a stroke or other causes of neurological disability. Higher scores are generally associated with less favorable outcomes. For this study patients with an mRS score of 0-2 will be determined to have had a "favorable" outcome to the procedure and patients with an mRS score of 3-5 will have been determined to have had an "unfavorable" outcome. Scoring will also include a 6 to identify patients who have expired. |
Up to 24 months post procedure
|
|
Immediate Angiographic Outcomes at Discharge - O'Kelly-Marotta (OKM) grading scale
時間枠:Upon study discharge, up to 4 weeks
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the OKM grading scale. The OKM scale will be used to assess the degree of angiographic filling and in the setting of intracranial aneurysms which were treated by endovascular flow diversion. It is used to predict aneurysm closure over time. Patient outcomes will be stratified based on the following scale scores: Grade A: Total filling (>95% of aneurysm remained); Grade B: Subtotal filling (5-95% of aneurysm remained); Grade C: Entry remnant (<5% aneurysm remained); and Grade D: No filling (0% aneurysm remained). As such, the less aneurysm remnant the more favorable the angiographic outcome. The number/percentage of cases of each OKM Grade will be summarized. |
Upon study discharge, up to 4 weeks
|
|
Immediate Angiographic Outcomes at Discharge - Modified Raymond-Roy Classification (mRRC)
時間枠:Upon study discharge, up to 4 weeks
|
Immediate Angiographic Outcomes at Discharge will also be evaluated using mRRC categorization. mRRC categorization will be used to assess the degree of occlusion achieved when treating an intracranial aneurysm. It categorizes the level of residual contrast filling within an aneurysm after coiling. For purposes of this analysis, Class I will signify complete occlusion; Class II will signify Residual neck occlusion; Class IIIa will signify Residual aneurysm with contrast stasis; and Class IIIb will signify Residual aneurysm without contrast stasis. As such, it is an indicator of how effectively the aneurysm has been sealed off during treatment. The number/percentage of cases of each mRRC category will be summarized. |
Upon study discharge, up to 4 weeks
|
|
Immediate Angiographic Outcomes at Discharge - WEB Occlusion Scale (WOS)
時間枠:Upon study discharge, up to 4 weeks
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the WOS grading scale. The WOS is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with endosaccular flow disruptors and can be employed to assess the adequacy of treatment. For purposes of this analysis, WOS Grade A will signify complete occlusion; WOS Grade B will signify Residual neck occlusion; and WOS Grade C will signify Residual aneurysm filling. The number/percentage of cases of each WOS grade category will be summarized. |
Upon study discharge, up to 4 weeks
|
|
Angiographic Outcomes at last available Follow-up - O'Kelly-Marotta (OKM) grading scale
時間枠:Up to 24 months post procedure
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the OKM grading scale. The OKM scale will be used to assess the degree of angiographic filling and in the setting of intracranial aneurysms which were treated by endovascular flow diversion. It is used to predict aneurysm closure over time. Patient outcomes will be stratified based on the following scale scores: Grade A: Total filling (>95% of aneurysm remained); Grade B: Subtotal filling (5-95% of aneurysm remained); Grade C: Entry remnant (<5% aneurysm remained); and Grade D: No filling (0% aneurysm remained). As such, the less aneurysm remnant the more favorable the angiographic outcome. The number/percentage of cases of each OKM Grade will be summarized. |
Up to 24 months post procedure
|
|
Angiographic Outcomes at last available Follow-up - Modified Raymond-Roy Classification (mRRC)
時間枠:Up to 24 months post procedure
|
Immediate Angiographic Outcomes at Discharge will also be evaluated using mRRC categorization. mRRC categorization will be used to assess the degree of occlusion achieved when treating an intracranial aneurysm. It categorizes the level of residual contrast filling within an aneurysm after coiling. For purposes of this analysis, Class I will signify complete occlusion; Class II will signify Residual neck occlusion; Class IIIa will signify Residual aneurysm with contrast stasis; and Class IIIb will signify Residual aneurysm without contrast stasis. As such, it is an indicator of how effectively the aneurysm has been sealed off during treatment. The number/percentage of cases of each mRRC category will be summarized. |
Up to 24 months post procedure
|
|
Angiographic Outcomes at last available Follow-up - WEB Occlusion Scale (WOS)
時間枠:Up to 24 months post procedure
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the WOS grading scale. The WOS is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with endosaccular flow disruptors and can be employed to assess the adequacy of treatment. For purposes of this analysis, WOS Grade A will signify complete occlusion; WOS Grade B will signify Residual neck occlusion; and WOS Grade C will signify Residual aneurysm filling. The number/percentage of cases of each WOS grade category will be summarized. |
Up to 24 months post procedure
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Radiation Exposure
時間枠:Periprocedurally, up to 4 hours
|
Radiation exposure over the course of the procedure will be extracted and summarized. Radiation exposure will be evaluated based on relevant imaging system metrics used to calculate the total radiation dose delivered to the patient based on the fluoroscopy time and the area of the X-ray field exposed during the procedure. Flow diverter stents and endosaccular flow disruptors typically result in significantly lower radiation exposure compared to other endovascular techniques for treating brain aneurysms due to a reduction in fluoroscopy time and overall reduced radiation dose due to the streamlined nature of the procedures. |
Periprocedurally, up to 4 hours
|
|
Procedure Duration
時間枠:Periprocedurally, up to 4 hours
|
The duration of procedure placement will be extracted and summarized. The duration of the procedure is influenced by the complexity of the aneurysm, the patient's anatomy, and the experience of the interventional radiologist and care team. Shorter procedure duration times are associated with more favorable outcomes. |
Periprocedurally, up to 4 hours
|
|
Use of Adjunct Devices
時間枠:Periprocedurally, up to 4 hours
|
The use of adjunctive devices such as coils, stents or balloons to further enhance aneurysm occlusion of the flow diverter stent or to facilitate positioning and deployment of the endosaccular flow disruptor within the aneurysm sac during the procedure will be extracted and summarized. The number of adjunct devices will be extracted and summarized. |
Periprocedurally, up to 4 hours
|
|
Recurrence of Aneurysm
時間枠:6 to 24 months post procedure
|
The percentage of patients who experienced aneurysm recurrence will be extracted and summarized based on a binary (Yes/No) determination following retrospective record review. The span of time from initial treatment to recurrence will be assessed and summarized. |
6 to 24 months post procedure
|
|
Aneurysm Retreatment
時間枠:6 to 24 months post procedure
|
The percentage of patients who required retreatment for a recurrence of aneurysm will be extracted and summarized based on a binary (Yes/No) determination following retrospective record review. The span of time from initial treatment to retreatment will be assessed and summarized. |
6 to 24 months post procedure
|
協力者と研究者
協力者
捜査官
- 主任研究者:David Altschul, MD、Montefiore Medical Center
出版物と役立つリンク
一般刊行物
- Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D. The pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol. 2011 Jan;32(1):34-40. doi: 10.3174/ajnr.A2421. Epub 2010 Dec 9.
- Hecker C, Broussalis E, Griessenauer CJ, Killer-Oberpfalzer M. A mini-review of intrasaccular flow diverters. J Neurointerv Surg. 2023 Jan;15(1):70-74. doi: 10.1136/neurintsurg-2021-018426. Epub 2022 May 17.
- Colby GP, Lin LM, Caplan JM, Jiang B, Michniewicz B, Huang J, Tamargo RJ, Coon AL. Flow diversion of large internal carotid artery aneurysms with the surpass device: impressions and technical nuance from the initial North American experience. J Neurointerv Surg. 2016 Mar;8(3):279-86. doi: 10.1136/neurintsurg-2015-011769. Epub 2015 May 18.
- Vivanco-Suarez J, Feigen C, Javed K, Dardick JM, Holland R, Mendez-Ruiz A, Ortega-Gutierrez S, Haranhalli N, Altschul DJ. Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms. Data Brief. 2022 May 21;42:108299. doi: 10.1016/j.dib.2022.108299. eCollection 2022 Jun.
- Wakhloo AK, Lylyk P, de Vries J, Taschner C, Lundquist J, Biondi A, Hartmann M, Szikora I, Pierot L, Sakai N, Imamura H, Sourour N, Rennie I, Skalej M, Beuing O, Bonafe A, Mery F, Turjman F, Brouwer P, Boccardi E, Valvassori L, Derakhshani S, Litzenberg MW, Gounis MJ; Surpass Study Group. Surpass flow diverter in the treatment of intracranial aneurysms: a prospective multicenter study. AJNR Am J Neuroradiol. 2015 Jan;36(1):98-107. doi: 10.3174/ajnr.A4078. Epub 2014 Aug 14.
- O'kelly CJ, Krings T, Fiorella D, Marotta TR. A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol. 2010 Jun;16(2):133-7. doi: 10.1177/159101991001600204. Epub 2010 Jul 19.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。