- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT06174727
Registro internacional de stents desviadores de flujo (IRF) (IRF)
Resultados de los desviadores de flujo para el tratamiento de aneurismas intracraneales: Registro internacional de stents desviadores de flujo (IRF)
This multicenter retrospective cohort study aims to evaluate and compare the technical performance, safety, and clinical outcomes of intracranial aneurysms treated with flow diverter stents and endosaccular flow disruptors.
Descripción general del estudio
Estado
Condiciones
Descripción detallada
Flow diverters and endosaccular flow disruptors used for the treatment of intracranial aneurysms exhibit distinct procedural and clinical outcomes, with potential differences in device-specific parameters such as procedure time, radiation exposure, adjunct device requirements, and long-term angiographic success. Since the completion of the Pipeline Embolization Device (PED) for the Intracranial Treatment of Aneurysms trial, the field of flow diversion has undergone continuous evolution with the development and approval of several devices. While these devices share a similar mechanism for aneurysm occlusion, their design and delivery systems can vary significantly. Various studies have demonstrated a promising safety and efficacy profile; however, the available data for a direct comparison of the technical and clinical outcomes between these devices remains limited.
The following collaborator is also involved in the research:
Name: Muhammed Amir Essibayi Email: m.amir.essibayi@gmail.com
Tipo de estudio
Inscripción (Estimado)
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Muhammed Amir Essibayi, MD
- Número de teléfono: 347-908-1889
- Correo electrónico: Muhammedamir.essibayi@einsteinmed.edu
Ubicaciones de estudio
-
-
Ontario
-
Toronto, Ontario, Canadá, M5B 1W8
- Reclutamiento
- St. Michael's Hospital
-
Investigador principal:
- Vitor Mendes Pereira, MD
-
Contacto:
- Vitor Mendes Pereira, MD
- Número de teléfono: 416-864-5131
- Correo electrónico: PereiraReferrals@unityhealth.to
-
Contacto:
- Eileen Liu, MSc
- Correo electrónico: eileen.liu@unityhealth.to
-
Toronto, Ontario, Canadá, M5T 2S8
- Reclutamiento
- Toronto Western Hospital
-
Contacto:
- Pascal Mosimann, MD, PD
- Número de teléfono: 416-603 5800
- Correo electrónico: pascal.mosimann@uhn.ca
-
Investigador principal:
- Pascal Mosimann, MD, PD
-
-
-
-
Florida
-
Coral Gables, Florida, Estados Unidos, 33146
- Reclutamiento
- University of Miami
-
Contacto:
- Robert M Starke, MD, MS
- Número de teléfono: 305-355-1101
- Correo electrónico: RStarke@med.miami.edu
-
Investigador principal:
- Robert M Starke, MD, MS
-
Jacksonville, Florida, Estados Unidos, 32224
- Terminado
- Mayo Clinic Florida
-
Sarasota, Florida, Estados Unidos, 34239
- Terminado
- Sarasota Memorial Research Institute
-
-
Massachusetts
-
Burlington, Massachusetts, Estados Unidos, 01805
- Reclutamiento
- Lahey Hospital and Medical Center
-
Contacto:
- Timo Krings, MD, PhD, MSc
- Número de teléfono: 781-744-3330
- Correo electrónico: Timo.Krings@lahey.org
-
Investigador principal:
- Timo Krings, MD, PhD, MSc
-
-
Michigan
-
Traverse City, Michigan, Estados Unidos, 49684
- Reclutamiento
- Munson Medical Center
-
Contacto:
- Amy Peterson, PhD
- Número de teléfono: 231-935-6746
- Correo electrónico: apeterson4@mhc.net
-
-
Minnesota
-
Minneapolis, Minnesota, Estados Unidos, 55404
- Reclutamiento
- Allina Health
-
Contacto:
- Collin M Torok, MD
- Número de teléfono: 612-863-0376
- Correo electrónico: collin.torok@allina.com
-
Contacto:
- Marie Meyer, MA
- Correo electrónico: marie.meyer@allina.com
-
Investigador principal:
- Collin M Torok, MD
-
-
New Jersey
-
New Brunswick, New Jersey, Estados Unidos, 08901
- Reclutamiento
- Robert Wood Johnson University
-
Investigador principal:
- Gaurav Gupta, MD
-
Contacto:
- Gaurav Gupta, MD
- Número de teléfono: 732-235-6333
- Correo electrónico: guptaga@rwjms.rutgers.edu
-
-
New York
-
Buffalo, New York, Estados Unidos, 14068
- Terminado
- University at Buffalo
-
The Bronx, New York, Estados Unidos, 10467
- Reclutamiento
- Montefiore Medical Center Department of Neurosurgery
-
Investigador principal:
- David Altschul, MD
-
Contacto:
- Muhammed Amir Essibayi, MD
- Número de teléfono: 347-908-1889
- Correo electrónico: Muhammedamir.essibayi@einsteinmed.edu
-
Contacto:
- David Altschul, MD
- Número de teléfono: (718) 920-7498
- Correo electrónico: daltschu@montefiore.org
-
-
Pennsylvania
-
Danville, Pennsylvania, Estados Unidos, 17822
- Terminado
- Geisinger Health
-
-
Texas
-
Kingwood, Texas, Estados Unidos, 77339
- Terminado
- HCA Houston Healthcare Kingwood
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Patients with intracranial aneurysms who underwent endovascular treatment with flow diverter stents or endosaccular flow disruptors
Descripción
Inclusion Criteria:
-
Consecutive adult patients (18 years of age or older)
-
Underwent endovascular treatment with one of the following devices:
a. Endoluminal Flow Diverter Stents: i. Pipeline Flex (Covidien, California, USA) ii. Pipeline Flex with Shield Technology (Covidien) iii. Surpass Streamline (Stryker Neurovascular, California, USA) iv. Surpass Evolve (Stryker) v. Silk flow diverter (Balt Extrusion, Montmorency, France) vi. Flow-Redirection Intraluminal Device (FRED; MicroVention) vii. Flow-Redirection Intraluminal Device X (FRED X; MicroVention) viii. p64 Flow Modulation Device (phenox GmbH) ix. Endovascular clip system (eCLIPs) (eCLIPsTM, eVasc Neurovascular, Vancouver, BC, Canada)
b. Intrasaccular Flow Disruptors: i. Woven EndoBridge (WEB; MicroVention) ii. Luna/Artisse System (Medtronic) iii. Medina Embolic Device (Medtronic) iv. Contour Neurovascular System (Cerus Endovascular) v. Neqstent Coil Assisted Flow Diverter (Cerus Endovascular) vi. pCONus and pCANvas (phenox GmbH) vii. Nexus Aneurysm Embolization System (EndoStream Medical) viii. CITADEL™ Embolization Device (Balt, USA)
-
Complete medical records and follow-up data available
Exclusion Criteria:
- Incomplete procedural or follow-up records
- Non-flow-diverter or non-flow-disruptor treatments (e.g., coiling-only cases)
- Aneurysms treated with investigational devices not listed within Inclusion Criteria
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: COHORT
- Perspectivas temporales: RETROSPECTIVE
Cohortes e Intervenciones
Grupo / Cohorte |
|---|
|
Endoluminal Flow Diverter Stent
Adults with intracranial aneurysms treated with an endoluminal flow diverter stent as part of routine care. |
|
Intrasaccular Flow Disruptor
Adults with intracranial aneurysms treated with an intrasaccular flow disruptor as part of routine care. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Technical Success
Periodo de tiempo: Periprocedurally, up to 24 hours
|
Technical Success will be determined by successful deployment of the flow diverter stent or endosaccular flow disruptors. A dichotomous determination (i.e., Yes/No) will be made and summarized for this study. |
Periprocedurally, up to 24 hours
|
|
Procedural Complications following placement
Periodo de tiempo: From the time of the procedure up to 1 month post treatment
|
Procedural complications will be identified as the number of instances of the following adverse clinical events: In-stent Thrombosis/Stenosis; Ischemic complications (Transient Ischemic Attack/Stroke), Intracerebral hemorrhage, Aneurysm rupture, and Vessel occlusion due to flow diverter stent or endosaccular flow disruptor placement. |
From the time of the procedure up to 1 month post treatment
|
|
Clinical Outcomes at Discharge
Periodo de tiempo: Upon study discharge, up to 4 weeks
|
Clinical outcomes at discharge will be assessed using the modified Rankin Scale (mRS) for neurologic disability. The mRS is a 6-point disability scale with possible scores ranging from 0-5. mRS measures the degree of disability or dependence in the daily activities of people who have suffered a stroke or other causes of neurological disability. Higher scores are generally associated with less favorable outcomes. For this study patients with an mRS score of 0-2 will be determined to have had a "favorable" outcome to the procedure and patients with an mRS score of 3-5 will have been determined to have had an "unfavorable" outcome. |
Upon study discharge, up to 4 weeks
|
|
Clinical Outcomes at last available Follow-up
Periodo de tiempo: Up to 24 months post procedure
|
Clinical outcomes at last available follow-up will be assessed using a variant of the modified Rankin Scale (mRS) for neurologic disability. The classic mRS is a 6-point disability scale with possible scores ranging from 0-5. mRS measures the degree of disability or dependence in the daily activities of people who have suffered a stroke or other causes of neurological disability. Higher scores are generally associated with less favorable outcomes. For this study patients with an mRS score of 0-2 will be determined to have had a "favorable" outcome to the procedure and patients with an mRS score of 3-5 will have been determined to have had an "unfavorable" outcome. Scoring will also include a 6 to identify patients who have expired. |
Up to 24 months post procedure
|
|
Immediate Angiographic Outcomes at Discharge - O'Kelly-Marotta (OKM) grading scale
Periodo de tiempo: Upon study discharge, up to 4 weeks
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the OKM grading scale. The OKM scale will be used to assess the degree of angiographic filling and in the setting of intracranial aneurysms which were treated by endovascular flow diversion. It is used to predict aneurysm closure over time. Patient outcomes will be stratified based on the following scale scores: Grade A: Total filling (>95% of aneurysm remained); Grade B: Subtotal filling (5-95% of aneurysm remained); Grade C: Entry remnant (<5% aneurysm remained); and Grade D: No filling (0% aneurysm remained). As such, the less aneurysm remnant the more favorable the angiographic outcome. The number/percentage of cases of each OKM Grade will be summarized. |
Upon study discharge, up to 4 weeks
|
|
Immediate Angiographic Outcomes at Discharge - Modified Raymond-Roy Classification (mRRC)
Periodo de tiempo: Upon study discharge, up to 4 weeks
|
Immediate Angiographic Outcomes at Discharge will also be evaluated using mRRC categorization. mRRC categorization will be used to assess the degree of occlusion achieved when treating an intracranial aneurysm. It categorizes the level of residual contrast filling within an aneurysm after coiling. For purposes of this analysis, Class I will signify complete occlusion; Class II will signify Residual neck occlusion; Class IIIa will signify Residual aneurysm with contrast stasis; and Class IIIb will signify Residual aneurysm without contrast stasis. As such, it is an indicator of how effectively the aneurysm has been sealed off during treatment. The number/percentage of cases of each mRRC category will be summarized. |
Upon study discharge, up to 4 weeks
|
|
Immediate Angiographic Outcomes at Discharge - WEB Occlusion Scale (WOS)
Periodo de tiempo: Upon study discharge, up to 4 weeks
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the WOS grading scale. The WOS is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with endosaccular flow disruptors and can be employed to assess the adequacy of treatment. For purposes of this analysis, WOS Grade A will signify complete occlusion; WOS Grade B will signify Residual neck occlusion; and WOS Grade C will signify Residual aneurysm filling. The number/percentage of cases of each WOS grade category will be summarized. |
Upon study discharge, up to 4 weeks
|
|
Angiographic Outcomes at last available Follow-up - O'Kelly-Marotta (OKM) grading scale
Periodo de tiempo: Up to 24 months post procedure
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the OKM grading scale. The OKM scale will be used to assess the degree of angiographic filling and in the setting of intracranial aneurysms which were treated by endovascular flow diversion. It is used to predict aneurysm closure over time. Patient outcomes will be stratified based on the following scale scores: Grade A: Total filling (>95% of aneurysm remained); Grade B: Subtotal filling (5-95% of aneurysm remained); Grade C: Entry remnant (<5% aneurysm remained); and Grade D: No filling (0% aneurysm remained). As such, the less aneurysm remnant the more favorable the angiographic outcome. The number/percentage of cases of each OKM Grade will be summarized. |
Up to 24 months post procedure
|
|
Angiographic Outcomes at last available Follow-up - Modified Raymond-Roy Classification (mRRC)
Periodo de tiempo: Up to 24 months post procedure
|
Immediate Angiographic Outcomes at Discharge will also be evaluated using mRRC categorization. mRRC categorization will be used to assess the degree of occlusion achieved when treating an intracranial aneurysm. It categorizes the level of residual contrast filling within an aneurysm after coiling. For purposes of this analysis, Class I will signify complete occlusion; Class II will signify Residual neck occlusion; Class IIIa will signify Residual aneurysm with contrast stasis; and Class IIIb will signify Residual aneurysm without contrast stasis. As such, it is an indicator of how effectively the aneurysm has been sealed off during treatment. The number/percentage of cases of each mRRC category will be summarized. |
Up to 24 months post procedure
|
|
Angiographic Outcomes at last available Follow-up - WEB Occlusion Scale (WOS)
Periodo de tiempo: Up to 24 months post procedure
|
Immediate Angiographic Outcomes at Discharge will be evaluated using the WOS grading scale. The WOS is a standardized angiographic assessment scale for reporting aneurysm occlusion achieved with endosaccular flow disruptors and can be employed to assess the adequacy of treatment. For purposes of this analysis, WOS Grade A will signify complete occlusion; WOS Grade B will signify Residual neck occlusion; and WOS Grade C will signify Residual aneurysm filling. The number/percentage of cases of each WOS grade category will be summarized. |
Up to 24 months post procedure
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Radiation Exposure
Periodo de tiempo: Periprocedurally, up to 4 hours
|
Radiation exposure over the course of the procedure will be extracted and summarized. Radiation exposure will be evaluated based on relevant imaging system metrics used to calculate the total radiation dose delivered to the patient based on the fluoroscopy time and the area of the X-ray field exposed during the procedure. Flow diverter stents and endosaccular flow disruptors typically result in significantly lower radiation exposure compared to other endovascular techniques for treating brain aneurysms due to a reduction in fluoroscopy time and overall reduced radiation dose due to the streamlined nature of the procedures. |
Periprocedurally, up to 4 hours
|
|
Procedure Duration
Periodo de tiempo: Periprocedurally, up to 4 hours
|
The duration of procedure placement will be extracted and summarized. The duration of the procedure is influenced by the complexity of the aneurysm, the patient's anatomy, and the experience of the interventional radiologist and care team. Shorter procedure duration times are associated with more favorable outcomes. |
Periprocedurally, up to 4 hours
|
|
Use of Adjunct Devices
Periodo de tiempo: Periprocedurally, up to 4 hours
|
The use of adjunctive devices such as coils, stents or balloons to further enhance aneurysm occlusion of the flow diverter stent or to facilitate positioning and deployment of the endosaccular flow disruptor within the aneurysm sac during the procedure will be extracted and summarized. The number of adjunct devices will be extracted and summarized. |
Periprocedurally, up to 4 hours
|
|
Recurrence of Aneurysm
Periodo de tiempo: 6 to 24 months post procedure
|
The percentage of patients who experienced aneurysm recurrence will be extracted and summarized based on a binary (Yes/No) determination following retrospective record review. The span of time from initial treatment to recurrence will be assessed and summarized. |
6 to 24 months post procedure
|
|
Aneurysm Retreatment
Periodo de tiempo: 6 to 24 months post procedure
|
The percentage of patients who required retreatment for a recurrence of aneurysm will be extracted and summarized based on a binary (Yes/No) determination following retrospective record review. The span of time from initial treatment to retreatment will be assessed and summarized. |
6 to 24 months post procedure
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: David Altschul, MD, Montefiore Medical Center
Publicaciones y enlaces útiles
Publicaciones Generales
- Nelson PK, Lylyk P, Szikora I, Wetzel SG, Wanke I, Fiorella D. The pipeline embolization device for the intracranial treatment of aneurysms trial. AJNR Am J Neuroradiol. 2011 Jan;32(1):34-40. doi: 10.3174/ajnr.A2421. Epub 2010 Dec 9.
- Hecker C, Broussalis E, Griessenauer CJ, Killer-Oberpfalzer M. A mini-review of intrasaccular flow diverters. J Neurointerv Surg. 2023 Jan;15(1):70-74. doi: 10.1136/neurintsurg-2021-018426. Epub 2022 May 17.
- Colby GP, Lin LM, Caplan JM, Jiang B, Michniewicz B, Huang J, Tamargo RJ, Coon AL. Flow diversion of large internal carotid artery aneurysms with the surpass device: impressions and technical nuance from the initial North American experience. J Neurointerv Surg. 2016 Mar;8(3):279-86. doi: 10.1136/neurintsurg-2015-011769. Epub 2015 May 18.
- Vivanco-Suarez J, Feigen C, Javed K, Dardick JM, Holland R, Mendez-Ruiz A, Ortega-Gutierrez S, Haranhalli N, Altschul DJ. Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms. Data Brief. 2022 May 21;42:108299. doi: 10.1016/j.dib.2022.108299. eCollection 2022 Jun.
- Wakhloo AK, Lylyk P, de Vries J, Taschner C, Lundquist J, Biondi A, Hartmann M, Szikora I, Pierot L, Sakai N, Imamura H, Sourour N, Rennie I, Skalej M, Beuing O, Bonafe A, Mery F, Turjman F, Brouwer P, Boccardi E, Valvassori L, Derakhshani S, Litzenberg MW, Gounis MJ; Surpass Study Group. Surpass flow diverter in the treatment of intracranial aneurysms: a prospective multicenter study. AJNR Am J Neuroradiol. 2015 Jan;36(1):98-107. doi: 10.3174/ajnr.A4078. Epub 2014 Aug 14.
- O'kelly CJ, Krings T, Fiorella D, Marotta TR. A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol. 2010 Jun;16(2):133-7. doi: 10.1177/159101991001600204. Epub 2010 Jul 19.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 2023-15177
- 2023 (Subvención/contrato del NIH de EE. UU.)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .