Study on OsseoSpeed™ TX Short Implants in a Chinese Population

2019년 10월 1일 업데이트: Dentsply Sirona Implants and Consumables

An Open, Prospective, Multi-center Study Assessing the OsseoSpeed™ TX Length 6 mm in in the Posterior Maxilla and Mandible. A 3-years Follow-up Study.

The purpose of this study is to investigate the clinical efficacy of OsseoSpeed™ TX 6 mm implants in a Chinese population by evaluation of marginal bone level alteration, implant stability and implant survival in the posterior mandible and maxilla up to 3 years after loading. The hypothesis is that one stage surgery using 6 mm OsseoSpeed™ TX implant in the posterior region is safe and predictable.

연구 개요

연구 유형

중재적

등록 (실제)

45

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • Beijing, 중국, 100081
        • Department of Periodontology, School of Stomatology, Peking University
      • Beijing, 중국
        • Department of Implantology, School of Stomatology, Peking University
      • Beijing, 중국
        • Second Dental and Periodontal Center, School of Stomatology, Peking University

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

20년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion criteria:

  1. Provision of informed consent
  2. Female and male aged 20-75 years at enrolment
  3. In need for 2-3 implants in either side of the posterior mandible or maxilla (premolar and molar region)
  4. History of edentulism in the study area of at least four months
  5. Neighboring tooth/teeth to the planned bridge/crowns must have natural root(s)
  6. Presence of natural teeth, partial prosthesis and/or implants in the opposite jaw in contact with the planned bridge/crowns
  7. Deemed by the investigator to be suitable for implants of 6 mm length and to have a bone height of at least 6 mm and a bone width of minimum 6 mm
  8. Deemed by the investigator as likely to present an initially stable implant situation

Exclusion criteria:

  1. Unlikely to be able to comply with study procedures, as judged by the investigator
  2. Earlier graft procedures in the study area
  3. Uncontrolled pathologic processes in the oral cavity
  4. Known or suspected current malignancy
  5. History of radiation therapy in the head and neck region
  6. History of chemotherapy within 5 years prior to surgery
  7. Systemic or local disease or condition that could compromise post-operative healing and/or osseointegration
  8. Uncontrolled diabetes mellitus
  9. Corticosteroids or any other medication that could influence post-operative healing and/or osseointegration
  10. Smoking more than 10 cigarettes/day
  11. Present alcohol and/or drug abuse
  12. Involvement in the planning and conduct of the study (applies to both Astra Tech staff and staff at the study site)
  13. Previous enrolment in the present study
  14. Simultaneous participation in another clinical study, or participation in a clinical study during the last 6 months
  15. Subjects that are unable to give informed consent

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 해당 없음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: OsseoSpeed™ TX implants
OsseoSpeed TX implants; Ø 4.0 mm, length 6 mm.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Marginal Bone Level Alteration
기간: Evaluated from implant installation to 12 months after implant loading

Marginal Bone Level determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant, and expressed in millimeters. Marginal Bone Level change calculated from values obtained at delivery of permanent restoration i.e. loading of implants (baseline) compared to the values obtained at the follow-up visit 12 months after loading.

Positive value = bone gain, Negative values = bone loss.

Evaluated from implant installation to 12 months after implant loading

2차 결과 측정

결과 측정
측정값 설명
기간
Marginal Bone Level Alteration After 36 Months
기간: Evaluated from implant loading to 36 months after implant loading.

Marginal Bone Level determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant, and expressed in millimeters. Marginal Bone Level change calculated from values obtained at delivery of permanent restoration i.e. loading of implants (baseline) compared to the values obtained at the follow-up visit 36 months after loading.

Positive value = bone gain, Negative values = bone loss.

Evaluated from implant loading to 36 months after implant loading.
Implant Survival
기간: Evaluated from implant installation to 36 months after implant loading.
Implant survival rate evaluated clinically and radiographically.
Evaluated from implant installation to 36 months after implant loading.
Implant Stability
기간: Evaluated 36 months after implant loading.
Implant stability evaluated clinically/manually (recorded as stable yes/no).
Evaluated 36 months after implant loading.
Condition of the Periimplant Mucosa (PPD).
기간: Evaluated from implant loading to 36 months after implant loading.

Condition of the periimplant mucosa measured by assessment of probing pocket depth (PPD).

Change in pocket depth expressed in millimeters at the 36 month follow-up visit compared to values obtained at delivery of permanent restoration i.e. loading (baseline).

Negative value = increased pocket depth

Evaluated from implant loading to 36 months after implant loading.
Condition of the Periimplant Mucosa (BoP).
기간: Evaluated from implant loading to 36 months after implant loading.

Condition of the periimplant mucosa will be measured by assessment of bleeding on probing (BoP).

Presented as % of the implants that show presence of bleeding at time of the 36 months follow-up.

Evaluated from implant loading to 36 months after implant loading.
Plaque
기간: Evaluated 36 months after implant loading.
Occurence of plaque around the study implant. Presented as proportion of implants that showed presence of plaque at the 36 months follow-up visit.
Evaluated 36 months after implant loading.
Crown-to-implant Ratio
기간: 12 months after implant loading
Crown height measured radiographically from the implant-abutment interface to the most coronal point on the prosthesis. The crown-to-implant ratio calculated from radiographs
12 months after implant loading

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Huan Xin Meng, Prof, Department of Periodontology, School of Stomatology, Beijing University

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2011년 2월 1일

기본 완료 (실제)

2016년 3월 1일

연구 완료 (실제)

2016년 3월 1일

연구 등록 날짜

최초 제출

2011년 5월 2일

QC 기준을 충족하는 최초 제출

2011년 5월 2일

처음 게시됨 (추정)

2011년 5월 3일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2019년 10월 8일

QC 기준을 충족하는 마지막 업데이트 제출

2019년 10월 1일

마지막으로 확인됨

2019년 10월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • CHN-0005

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .