このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Study on OsseoSpeed™ TX Short Implants in a Chinese Population

2019年10月1日 更新者:Dentsply Sirona Implants and Consumables

An Open, Prospective, Multi-center Study Assessing the OsseoSpeed™ TX Length 6 mm in in the Posterior Maxilla and Mandible. A 3-years Follow-up Study.

The purpose of this study is to investigate the clinical efficacy of OsseoSpeed™ TX 6 mm implants in a Chinese population by evaluation of marginal bone level alteration, implant stability and implant survival in the posterior mandible and maxilla up to 3 years after loading. The hypothesis is that one stage surgery using 6 mm OsseoSpeed™ TX implant in the posterior region is safe and predictable.

調査の概要

研究の種類

介入

入学 (実際)

45

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Beijing、中国、100081
        • Department of Periodontology, School of Stomatology, Peking University
      • Beijing、中国
        • Department of Implantology, School of Stomatology, Peking University
      • Beijing、中国
        • Second Dental and Periodontal Center, School of Stomatology, Peking University

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

20年~75年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion criteria:

  1. Provision of informed consent
  2. Female and male aged 20-75 years at enrolment
  3. In need for 2-3 implants in either side of the posterior mandible or maxilla (premolar and molar region)
  4. History of edentulism in the study area of at least four months
  5. Neighboring tooth/teeth to the planned bridge/crowns must have natural root(s)
  6. Presence of natural teeth, partial prosthesis and/or implants in the opposite jaw in contact with the planned bridge/crowns
  7. Deemed by the investigator to be suitable for implants of 6 mm length and to have a bone height of at least 6 mm and a bone width of minimum 6 mm
  8. Deemed by the investigator as likely to present an initially stable implant situation

Exclusion criteria:

  1. Unlikely to be able to comply with study procedures, as judged by the investigator
  2. Earlier graft procedures in the study area
  3. Uncontrolled pathologic processes in the oral cavity
  4. Known or suspected current malignancy
  5. History of radiation therapy in the head and neck region
  6. History of chemotherapy within 5 years prior to surgery
  7. Systemic or local disease or condition that could compromise post-operative healing and/or osseointegration
  8. Uncontrolled diabetes mellitus
  9. Corticosteroids or any other medication that could influence post-operative healing and/or osseointegration
  10. Smoking more than 10 cigarettes/day
  11. Present alcohol and/or drug abuse
  12. Involvement in the planning and conduct of the study (applies to both Astra Tech staff and staff at the study site)
  13. Previous enrolment in the present study
  14. Simultaneous participation in another clinical study, or participation in a clinical study during the last 6 months
  15. Subjects that are unable to give informed consent

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:OsseoSpeed™ TX implants
OsseoSpeed TX implants; Ø 4.0 mm, length 6 mm.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Marginal Bone Level Alteration
時間枠:Evaluated from implant installation to 12 months after implant loading

Marginal Bone Level determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant, and expressed in millimeters. Marginal Bone Level change calculated from values obtained at delivery of permanent restoration i.e. loading of implants (baseline) compared to the values obtained at the follow-up visit 12 months after loading.

Positive value = bone gain, Negative values = bone loss.

Evaluated from implant installation to 12 months after implant loading

二次結果の測定

結果測定
メジャーの説明
時間枠
Marginal Bone Level Alteration After 36 Months
時間枠:Evaluated from implant loading to 36 months after implant loading.

Marginal Bone Level determined from radiographs and expressed as the difference from a reference point on the implant to the most coronal bone-to-implant contact on the mesial and distal aspect of the implant, and expressed in millimeters. Marginal Bone Level change calculated from values obtained at delivery of permanent restoration i.e. loading of implants (baseline) compared to the values obtained at the follow-up visit 36 months after loading.

Positive value = bone gain, Negative values = bone loss.

Evaluated from implant loading to 36 months after implant loading.
Implant Survival
時間枠:Evaluated from implant installation to 36 months after implant loading.
Implant survival rate evaluated clinically and radiographically.
Evaluated from implant installation to 36 months after implant loading.
Implant Stability
時間枠:Evaluated 36 months after implant loading.
Implant stability evaluated clinically/manually (recorded as stable yes/no).
Evaluated 36 months after implant loading.
Condition of the Periimplant Mucosa (PPD).
時間枠:Evaluated from implant loading to 36 months after implant loading.

Condition of the periimplant mucosa measured by assessment of probing pocket depth (PPD).

Change in pocket depth expressed in millimeters at the 36 month follow-up visit compared to values obtained at delivery of permanent restoration i.e. loading (baseline).

Negative value = increased pocket depth

Evaluated from implant loading to 36 months after implant loading.
Condition of the Periimplant Mucosa (BoP).
時間枠:Evaluated from implant loading to 36 months after implant loading.

Condition of the periimplant mucosa will be measured by assessment of bleeding on probing (BoP).

Presented as % of the implants that show presence of bleeding at time of the 36 months follow-up.

Evaluated from implant loading to 36 months after implant loading.
Plaque
時間枠:Evaluated 36 months after implant loading.
Occurence of plaque around the study implant. Presented as proportion of implants that showed presence of plaque at the 36 months follow-up visit.
Evaluated 36 months after implant loading.
Crown-to-implant Ratio
時間枠:12 months after implant loading
Crown height measured radiographically from the implant-abutment interface to the most coronal point on the prosthesis. The crown-to-implant ratio calculated from radiographs
12 months after implant loading

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Huan Xin Meng, Prof、Department of Periodontology, School of Stomatology, Beijing University

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2011年2月1日

一次修了 (実際)

2016年3月1日

研究の完了 (実際)

2016年3月1日

試験登録日

最初に提出

2011年5月2日

QC基準を満たした最初の提出物

2011年5月2日

最初の投稿 (見積もり)

2011年5月3日

学習記録の更新

投稿された最後の更新 (実際)

2019年10月8日

QC基準を満たした最後の更新が送信されました

2019年10月1日

最終確認日

2019年10月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • CHN-0005

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

OsseoSpeed™ TX implant (Ø 4.0 mm, length 6 mm)の臨床試験

3
購読する