이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

단일 운영기 레이저 보조 T 자형 프로브와 성인의 전통적인 초음파 유도 기술 (≥ 18 세) 사이의 첫 번째 문제에 대한 내부 경정 정맥 카테터 삽입의 성공률을 비교합니다.

2026년 8월 14일 업데이트: Zhiwen Li, The First Hospital of Jilin University

초음파 유도 내부 경정맥 카테터 삽입을위한 혁신적인 T 자형 프로브를 갖춘 평면 외-실시간 바이 플레인 단일 운영자 레이저 보조 : 무작위 임상 시험

Background: Ultrasound guidance is an important technique to improve the success rate of internal jugular vein catheterization (IJVC) at the first-attempt, however, both long-axis in-plane and short-axis out-of-plane techniques have their own disadvantages. The T-shaped ultrasonic probe invented by us combined with the help of laser positioning and 3D printing manipulator could realize real-time bi-plane guidance of the needle short-axis out-of-plane and long-axis in-plane. With the help of the Single-operator Laser-assisted T-shaped probe, the whole process of needle insertion, guide wire placement and catheter placement can be visualized, which is expected to improve the success rate on the first-attempt.

Objective: The primary outcome was the first-attempt success rate of initial RIJV catheterization without complications. The completion of the catheterization was defined as the presentation of the CVP waveform on the monitor. The secondary outcomes included first-attempt puncture success rate,first-attempt catheterisation success rate,overall catheterisation success rate,first-attempt needle tip location,first-attempt needle tip midline placement rate,number of needle direction adjustments,number of ultrasound probe repositionings, number of puncture attempts,first-attempt localisation time,first-attempt guidewire insertion success time,overall catheterisation success time.

Design, Setting, and Participants: This single-center, prospective, parallel-group, randomized controlled study enrolled surgical patients over 18 years and older (ASA grade Ⅰ-Ⅳ) who required IJVC ,fully understands the benefits and risks of the study, participates voluntarily, and signs the informed consent form in the First Hospital of Jilin University. The exclusion criteria were congenital abnormal development of the internal jugular vein; prior puncture at the same site last month; puncture site injury, infection, or hematoma; right neck surgery history and neck fixation due to surgery or injury. The participants were randomized into the traditional ultrasound-guidance group or the single-operator Laser-assisted T-shaped probe ultrasound-guidance group. After inducing general anesthesia, ultrasound-guided internal jugular vein catheterization was performed by the experienced operators.

Interventions: 352 patients were stratified into eight subgroups based on whether common carotid artery coverage exceeded 50% ,internal jugular vein depth exceeded 10mm , and internal jugular vein anteroposterior diameter exceeded 10mm . Each subgroup generated an independent randomisation sequence according to the block randomisation principle (T-mode ultrasound-guided group and 'long-axis plane' ultrasound-guided group). Upon enrolment, new subjects were assigned to corresponding subgroups based on stratification factors. Within each subgroup's dedicated random sequence, the allocation plan (T-shaped ultrasound guidance group or 'long-axis plane' ultrasound guidance group) was sequentially retrieved and marked. The next subject in that subgroup would receive the subsequent plan in the sequence. The operating team comprised six physicians (including two residents, two specialists, and two anaesthesiologists), who were not involved in other aspects of the study. Given the significant technical differences between the two approaches, the operators, equipment assistants, and research assistants were aware of the groupings. Conversely, participants' families were unaware of the groupings and could withdraw from the trial at any time. All data were collected and analysed by the same research assistant.

연구 개요

상세 설명

After the patient was admitted to the operating room, the vital signs of the patients were monitored,the thoraco-chin distance (the distance between the mandible and the upper edge of the sternostemma in cm when the patient's head was tilted back as far as possible) and neck circumference (the thinest neck, that is, the upper edge of the 7th cervical vertebra to the horizontal position below the Adam's apple in cm) were measured and recorded in the supine position. After the establishment of peripheral venous access, the patients received rapid induction of general anesthesia and tracheal intubation. Without special circumstances, the right internal jugular vein was selected by the operator after randomization. The probe frequency of 13 MHz and a depth of 4.0 cm were set for optimal image quality in both groups. The patient was placed in a supine position with the head 15 degrees lower and the head turned to the left to fully expose the right side of the neck, and a thin pillow was placed under the right shoulder if necessary.

T-type ultrasound guidance unit:

A 3D marking laser with laser emitter is mounted on the T-type ultrasound probe.The laser emitter is positioned directly above the Mark point on the short-axis plane of the T-shaped ultrasound probe. Due to the probe's hardware structure-where the long and short-axis probes are vertically and tightly fused, with the long-axis probe's centreline perpendicular to and passing through the short-axis probe's centreline-the emitted laser lies on the skin surface extension of the short-axis plane's centreline. Instruct the assistant to apply an appropriate amount ofcoupling agent evenly onto the ultrasound probe. The operator and assistant collaborate to cover the entire 3D-printed three-axis adjustable support arm and ultrasound probe with a sterile sleeve, evacuating any air between the probe and the sleeve. Coupling agent is then applied evenly to the outer layer of the sterile sleeve where it contacts the patient's skin,completing the equipment preparation. To commence positioning, the operator controls gently place the T-shaped ultrasound probe onto the patient's neck skin, positioning the short axis cephalad and the long axis caudally.Adjust the arm and rotation axis so the midline of the short-axis image centres the transverse section of the internal jugular vein. The laser direction now indicates the cutaneous pathway to the vein's centre point, coinciding with the long-axis probe's midline. Adjust the slide rail to align the midpoint of the short-axis probe with the marked point, then continue sliding 1 cm cephalad to ensure the needle tip approaches the maximum transverse plane level upon subcutaneous entry into the internal jugular vein. Positioning is complete. Secure the arm to stabilise the probe against the skin surface, establishing hands-free, stable, and continuously monitored ultrasound guidance. The operator's left hand stabilises the skin near the puncture site.

The right hand holds the puncture needle at a 45° angle to the skin, with the needle body aligned with the laser path and closely following the short-axis probe's MARK point during insertion, while simultaneously performing aspiration. Once the needle tip enters the subcutaneous tissue, if deviation is observed in the short-axis ultrasound image, adjust the insertion angle to penetrate the anterior wall directly above the internal jugular vein. Upon visualising needle entry into the vessel on both short-axis and long-axis ultrasound images, and observing uninterrupted, non-pulsatile venous blood return in the syringe, adjust the needle tip position to the centre of the longitudinal section of the internal jugular vein using the long-axis view. Subsequently, while maintaining the needle position with the left hand, slide the probe distally with the right hand and determine the needle tip position prior to guidewire placement using the 'dynamic needle tip method' via the short-axis plane image. Save a screenshot for the initial needle tip position assessment. During this attempt, the needle tip position remains fixed. Insert the guidewire 30 cm without resistance through the lumen at the rear end of the syringe connected to the tip of the puncture needle. Under guidewire guidance, place the guide catheter 12-15 cm into the internal jugular vein. If resistance persists, withdraw the guidewire and puncture needle from the internal jugular vein and apply pressure to the puncture site with sterile gauze for approximately 3 minutes. Subsequent attempts may proceed once no significant bleeding is observed at the puncture site. During this process, the timer shall not be paused, and the number of ultrasound probe repositionings and needle tip adjustments shall be recorded throughout.

Ultrasound-guided group within the longitudinal axis plane:

The assistant applies coupling agent to the surface of the ultrasound probe. The operator and assistant collaborate to cover the probe with a sterile sleeve, evacuating any air between the probe and sleeve. Coupling agent is then evenly applied to the outer layer of the sterile sleeve where it contacts the patient's skin, completing device preparation. To commence localisation, the operator holds the ultrasound probe with the left hand, aligning its longitudinal axis parallel to the course of the internal jugular vein. After superimposing the midpoint of the probe's longitudinal axis plane with the marked point, the probe is slid further along the longitudinal axis towards the cephalic direction by 1 cm. This ensures the needle tip approaches the most transverse plane. Stabilise the probe with the left hand to complete positioning.Hold the puncture needle at a 45° angle to the skin with the needle body aligned along the longitudinal axis.

Advance the needle closely alongside the midpoint of the probe's longitudinal axis while aspirating.Upon subcutaneous entry, if the needle trajectory deviates on the longitudinal ultrasound image, adjust the insertion angle or reposition the probe to ensure the needle tip penetrates directly above the internal jugular vein.

After confirming vascular entry on ultrasound and observing unobstructed venous blood return in the syringe, adjust the needle tip position to ensure the needle tip penetrates directly above the internal jugular vein. Upon visualising vascular entry in the ultrasound image and observing uninterrupted, pulsatile venous blood in the syringe, adjust the needle tip position to align it with the midpoint of the longitudinal axis plane of the internal jugular vein. At this stage, the right hand should stabilise the needle immovably, while the left hand manipulates the ultrasound probe to determine the needle tip position relative to the longitudinal axis plane using the the 'dynamic needle tip method' to determine the needle tip position prior to guidewire placement. Save a screenshot for the initial needle tip position assessment. During this attempt, the needle tip position remains unchanged. Insert the guidewire 30 cm without resistance through the lumen at the end of the syringe connected to the needle tip. Under guidewire guidance, place a 12-15 cm internal jugular vein catheter and secure it properly. Should significant resistance occur during guidewire insertion, withdraw the wire. After repositioning the ultrasound probe and adjusting the intravascular needle tip, reinsert the guidewire.If resistance persists, withdraw both the guidewire and puncture needle from the internal jugular vein. Apply pressure to the puncture site with sterile gauze for approximately 3 minutes.

The operation timer shall not be paused during this interval, and the number of ultrasound probe repositionings and needle tip adjustments shall be recorded throughout.

From patient admission to the operating theatre until completion of follow-up, the research assistant shall tick and record the following data in the CRF form: age, gender, height, weight, surgical scheduling (elective or emergency), surgical category, ASA classification, comorbidities, pre-procedural MAP, presence of coagulation, anticoagulant therapy status, antiplatelet therapy status,sternocleidomastoid distance, neck circumference, anterior/posterior jugular vein diameter and depth, common carotid artery coverage, initial catheterisation success, initial puncture success, initial needle tip position score, needle tip adjustment count, ultrasound probe repositioning count, total attempts, device preparation time, initial positioning time, initial guidewire Overall catheterisation success time, occurrence of complications (posterior jugular vein puncture, arterial puncture, haematoma, haemothorax, pneumothorax, nerve injury, jugular vein thrombosis), operator's assessment of the procedure (0-10 points, 0 being dissatisfied, 10 being highly satisfied).

연구 유형

중재적

등록 (실제)

384

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Jilin
      • Changchun, Jilin, 중국, 130021
        • the first hospital of Jilin University

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • The patient fully understood the benefits and risks of the study, voluntarily participated, and signed the informed consent form
  • Require internal jugular vein catheterization
  • ASA grade I~IV
  • Over 18 years and older

Exclusion Criteria:

  • Congenital malformation or abnormal development of the internal jugular vein;
  • Prior internal jugular vein catheterization performed within the past month
  • Puncture site injury, infection, or hematoma
  • History of surgical intervention in the right neck region
  • Restricted neck mobility due to prior surgery or traumatic injury

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: 기존의 초음파 유도 하의 인플레인 그룹

Ultrasonic (Huasheng Color Ultrasonic Diagnostic System, Navi s, Shenzhen Huasheng Medical Technology Co., LTD.) and a 4.0MHz phased probe were used for the long-axis in-plane internal jugular vein catheterization

실험적: the Single-operator Laser-assisted T-shaped probe group

The Single-operator Laser-assisted T-shaped probe consisted of TuoRen Ultrasonic System (TUR200, Shenzhen Tuoren Bio-Medical Electronics Co., LTD) with a T-shaped probe (L38T7C), a 3D-printed probe-carrying enclosure with a linear laser transmitter ( ZLM120AL650-22130BXS, Shenzhen Zhonglai Technology Co., Ltd.) and ultrasonic probe manipulator.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
the First-attempt Success Rate of Internal Jugular Vein Catheterization Without Complications
기간: perioperative/periprocedural

Number of participants where the initial puncture and catheterisation attempts were both successful, and no complications were observed during the procedure or during follow-up ultrasound examinations, the case is considered a successful first-attempt catheterisation without complications.

perioperative/periprocedural

2차 결과 측정

결과 측정
측정값 설명
기간
First-attempt Puncture Success Rate
기간: perioperative/periprocedural

During the first attempt pucture, the ultrasound scan shows that the needle tip is in the vein, and unpulsatile blood flow is visible in the syringe, the case is considered a first-attempt success puncture. Number of participants where the initial puncture attempts were successful.

perioperative/periprocedural
Overall Catheterization Success Rate
기간: perioperative/periprocedural

Internal jugular vein catheterisation is considered success if the number of puncture attempts is no more than 3 and the time taken for puncture and catheter placement is less than 10 minutes. Number of participants where the overall catheterization were successful.

perioperative/periprocedural
First-attempt Needle Tip Positioning Score
기간: perioperative/periprocedural

Divide the cross-section of the internal jugular vein into 12 quadrants, assigning each quadrant a score based on its position within the quadrant, ranging from a minimum of 1 point to a maximum of 5 points.The Higher the score,the closer it is to the midpoint of the cross-section.

perioperative/periprocedural
First-attempt Needle Tip Midpoint Placement
기간: perioperative/periprocedural

The proportion of cases in this group where the first-attempt needle tip positioning score is 5

perioperative/periprocedural
Number of Needle Direction Adjustments During Puncture
기간: perioperative/periprocedural

The number of adjustments made to the needle tip's direction from the moment the needle first penetrates the skin until the catheter is successfully placed.

perioperative/periprocedural
Number of Ultrasound Probe Repositionings
기간: perioperative/periprocedural

The number of ultrasound probe movements made to obtain the best ultrasound image during the procedure from the moment the puncture needle penetrates the skin until the successful placement of the catheter in the internal jugular vein.

perioperative/periprocedural
Total Number of Puncture Attempts
기간: perioperative/periprocedural

A puncture attempt is defined as the period from the moment the operator inserts the needle into the skin until the needle is removed. The number of puncture attempts is the total number of attempts made from the start of the procedure until successful puncture.

perioperative/periprocedural
Time for First-attempt Localization
기간: perioperative/periprocedural

The time taken from the moment the ultrasound probe first makes contact with the patient's neck until the optimal ultrasound image is obtained

perioperative/periprocedural
Time for First-attempt Successful Guidewire Insertion
기간: perioperative/periprocedural

The time taken from the initial attempt to insert the needle into the skin until the guidewire is successfully advanced 30 cm into the syringe without resistance.

perioperative/periprocedural
Total Time for Successful Catheterisation
기간: perioperative/periprocedural

The time taken from the first attempt to insert the needle into the skin until the successful placement of the intravenous catheter.

perioperative/periprocedural
Number of Participants With Mechanical Complications
기간: perioperative/periprocedural

Ultrasound examination during the internal jugular vein catheterisation procedure, immediately following successful placement, and during follow-up is used to detect complications associated with internal jugular vein catheterisation, including: puncture of the posterior wall of the internal jugular vein, arterial puncture, haematoma, haemothorax, pneumothorax, nerve injury, internal jugular vein thrombosis and puncture site bleeding.

perioperative/periprocedural
Operator Satisfaction Score
기간: perioperative/periprocedural

The operator's rating of the procedure: a score of 0 indicates 'very unsatisfactory', and a score of 10 indicates 'very satisfactory'.

perioperative/periprocedural

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 1월 12일

기본 완료 (실제)

2026년 5월 21일

연구 완료 (실제)

2026년 5월 21일

연구 등록 날짜

최초 제출

2025년 4월 20일

QC 기준을 충족하는 최초 제출

2025년 4월 26일

처음 게시됨 (실제)

2025년 5월 6일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 11월 5일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 8월 14일

마지막으로 확인됨

2026년 1월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 2025-169

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다