The Effect and Mechanism of Electroacupuncture on Acute Chemotherapy-induced Nausea and Vomiting
Studie Overzicht
Toestand
Toestand
Conditie
Conditie
Interventie / Behandeling
Interventie / Behandeling
Studietype
Studietype
Inschrijving (Verwacht)
Inschrijving
Fase
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
Studiecontact
- Naam: Jin, Doctor
- E-mail: king-jlm@163.com
Studie Locaties
-
-
Shaanxi
-
Xi'an, Shaanxi, China, 710032
- Werving
- Xijing Hospital
-
Contact:
- Yang
- Telefoonnummer: 86(029)-84775343
-
-
Deelname Criteria
Geschiktheidscriteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- First diagnosed stage Ⅲ-Ⅳ lung cancer patients on cisplatin chemotherapy;
- Right-handed and aged 18 to 75 years;
- Karnosky performance status (KPS) ≥ 70;
- Life expectancy ≥ 6 months.
Exclusion Criteria:
- Had brain metastases or other concurrent life-threatening diseases;
- Nausea and/or vomiting were present 24h before chemotherapy treatment;
- Suffered from or had a history of gastrointestinal diseases;
- Had a history of head trauma, serious neurological or psychiatric disorders;
- Participating in other clinical trials currently;
- Had any contraindication to exposure to a high magnetic field or receive acupuncture
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Preventie
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Verdrievoudigen
Aantal wapens
Wapens en interventies
Deelnemersgroep / ArmDeelnemersgroep / Arm |
Interventie / BehandelingInterventie / Behandeling |
|---|---|
|
Experimenteel: Acupuncture 1
In this group, patients separately received twice electroacupuncture at bilateral PC6 acupoint before and after Cisplatin administration on the first day of chemotherapy.
|
The needles used were Huatuo brand (Suzhou, China) sterile disposable stainless steel filiform; needles sized 0.25*25 mm.
After disinfection, needles were inserted 0.5 to 0.8 inches into the skin and were manipulated manually to obtain Deqi.
An electric stimulator (Huatuo SDZ-V, Suzhou, China) was connected to the needles and delivered a constant-current, 0.2-ms, density-wave, stimulus of 2 to 10-Hz frequency, level of intensity was as much as tolerable, but not painful to the subjects.
The needles were left for 30 minutes and then removed.
|
|
Experimenteel: Acupuncture 2
In this group, patients separately received twice electroacupuncture at bilateral PC6 and RN12 acupoints before and after Cisplatin administration on the first day of chemotherapy.
|
The needles used were Huatuo brand (Suzhou, China) sterile disposable stainless steel filiform; needles sized 0.25*25 mm.
After disinfection, needles were inserted 0.5 to 0.8 inches into the skin and were manipulated manually to obtain Deqi.
An electric stimulator (Huatuo SDZ-V, Suzhou, China) was connected to the needles and delivered a constant-current, 0.2-ms, density-wave, stimulus of 2 to 10-Hz frequency, level of intensity was as much as tolerable, but not painful to the subjects.
The needles were left for 30 minutes and then removed.
|
|
Sham-vergelijker: Sham acupuncture
In this group, patients separately received twice electroacupuncture at bilateral nonacupuncture point (S1 located at lateral of flexor carpi radialis, 2 cun above the wrist.
S2 located at 3 cun right side of RN12) before and after Cisplatin administration on the first day of chemotherapy.
|
The needles used were Huatuo brand (Suzhou, China) sterile disposable stainless steel filiform; needles sized 0.25*25 mm.
After disinfection, needles were inserted 0.5 to 0.8 inches into the skin and were manipulated manually to obtain Deqi.
An electric stimulator (Huatuo SDZ-V, Suzhou, China) was connected to the needles and delivered a constant-current, 0.2-ms, density-wave, stimulus of 2 to 10-Hz frequency, level of intensity was as much as tolerable, but not painful to the subjects.
The needles were left for 30 minutes and then removed.
|
|
Geen tussenkomst: Waitinglist control
In this group, patients received no electroacupuncture
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
The scores of Rhodes Index of Nausea, Vomiting and Retching.
Tijdsspanne: 24 hours
|
24 hours
|
Secundaire uitkomstmaten
Secundaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Content of 5-hiaa in urine
Tijdsspanne: 12 hours
|
12 hours
|
|
Heart Rate Variability
Tijdsspanne: 1 hour
|
1 hour
|
|
Tachygastria percentage
Tijdsspanne: 1 hour
|
1 hour
|
|
Dosage of antiemetic drugs
Tijdsspanne: 24 hours
|
24 hours
|
Andere uitkomstmaten
Andere uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Neuroimaging data
Tijdsspanne: 24 hours
|
24 hours
|
Medewerkers en onderzoekers
Sponsor
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start
Studie start
Primaire voltooiing (Verwacht)
Primaire voltooiing
Studieregistratiedata
Eerst ingediend
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Eerst geplaatst
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update geplaatst
Laatste update ingediend die voldeed aan QC-criteria
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
Andere studie-ID-nummers
- 2014CB543203
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .