The Effect and Mechanism of Electroacupuncture on Acute Chemotherapy-induced Nausea and Vomiting
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Oczekiwany)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
Kontakt w sprawie studiów
- Nazwa: Jin, Doctor
- E-mail: king-jlm@163.com
Lokalizacje studiów
-
-
Shaanxi
-
Xi'an, Shaanxi, Chiny, 710032
- Rekrutacyjny
- Xijing Hospital
-
Kontakt:
- Yang
- Numer telefonu: 86(029)-84775343
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- First diagnosed stage Ⅲ-Ⅳ lung cancer patients on cisplatin chemotherapy;
- Right-handed and aged 18 to 75 years;
- Karnosky performance status (KPS) ≥ 70;
- Life expectancy ≥ 6 months.
Exclusion Criteria:
- Had brain metastases or other concurrent life-threatening diseases;
- Nausea and/or vomiting were present 24h before chemotherapy treatment;
- Suffered from or had a history of gastrointestinal diseases;
- Had a history of head trauma, serious neurological or psychiatric disorders;
- Participating in other clinical trials currently;
- Had any contraindication to exposure to a high magnetic field or receive acupuncture
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Zapobieganie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Potroić
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: Acupuncture 1
In this group, patients separately received twice electroacupuncture at bilateral PC6 acupoint before and after Cisplatin administration on the first day of chemotherapy.
|
The needles used were Huatuo brand (Suzhou, China) sterile disposable stainless steel filiform; needles sized 0.25*25 mm.
After disinfection, needles were inserted 0.5 to 0.8 inches into the skin and were manipulated manually to obtain Deqi.
An electric stimulator (Huatuo SDZ-V, Suzhou, China) was connected to the needles and delivered a constant-current, 0.2-ms, density-wave, stimulus of 2 to 10-Hz frequency, level of intensity was as much as tolerable, but not painful to the subjects.
The needles were left for 30 minutes and then removed.
|
|
Eksperymentalny: Acupuncture 2
In this group, patients separately received twice electroacupuncture at bilateral PC6 and RN12 acupoints before and after Cisplatin administration on the first day of chemotherapy.
|
The needles used were Huatuo brand (Suzhou, China) sterile disposable stainless steel filiform; needles sized 0.25*25 mm.
After disinfection, needles were inserted 0.5 to 0.8 inches into the skin and were manipulated manually to obtain Deqi.
An electric stimulator (Huatuo SDZ-V, Suzhou, China) was connected to the needles and delivered a constant-current, 0.2-ms, density-wave, stimulus of 2 to 10-Hz frequency, level of intensity was as much as tolerable, but not painful to the subjects.
The needles were left for 30 minutes and then removed.
|
|
Pozorny komparator: Sham acupuncture
In this group, patients separately received twice electroacupuncture at bilateral nonacupuncture point (S1 located at lateral of flexor carpi radialis, 2 cun above the wrist.
S2 located at 3 cun right side of RN12) before and after Cisplatin administration on the first day of chemotherapy.
|
The needles used were Huatuo brand (Suzhou, China) sterile disposable stainless steel filiform; needles sized 0.25*25 mm.
After disinfection, needles were inserted 0.5 to 0.8 inches into the skin and were manipulated manually to obtain Deqi.
An electric stimulator (Huatuo SDZ-V, Suzhou, China) was connected to the needles and delivered a constant-current, 0.2-ms, density-wave, stimulus of 2 to 10-Hz frequency, level of intensity was as much as tolerable, but not painful to the subjects.
The needles were left for 30 minutes and then removed.
|
|
Brak interwencji: Waitinglist control
In this group, patients received no electroacupuncture
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
|---|---|
|
The scores of Rhodes Index of Nausea, Vomiting and Retching.
Ramy czasowe: 24 hours
|
24 hours
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Ramy czasowe |
|---|---|
|
Content of 5-hiaa in urine
Ramy czasowe: 12 hours
|
12 hours
|
|
Heart Rate Variability
Ramy czasowe: 1 hour
|
1 hour
|
|
Tachygastria percentage
Ramy czasowe: 1 hour
|
1 hour
|
|
Dosage of antiemetic drugs
Ramy czasowe: 24 hours
|
24 hours
|
Inne miary wyników
Inne miary wyników
Miara wyniku |
Ramy czasowe |
|---|---|
|
Neuroimaging data
Ramy czasowe: 24 hours
|
24 hours
|
Współpracownicy i badacze
Sponsor
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Oczekiwany)
Zakończenie podstawowe
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- 2014CB543203
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .