Rotational Stability of Two Soft Toric Contact Lens Designs
Comparison of Rotational Behavior of Soft Toric Contact Lenses With Different Stabilization Designs and Their Association With Ocular Biometric Parameters
Studie Overzicht
Toestand
Toestand
Conditie
Conditie
Interventie / Behandeling
Interventie / Behandeling
Studietype
Studietype
Inschrijving (Werkelijk)
Inschrijving
Fase
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Yozgat
-
Yozgat, Yozgat, Turkije (Türkiye), 66100
- Yozgat Bozok University Research and Application Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- Adults with astigmatic refractive error suitable for correction with the -commercially available toric contact lenses used in the study
- No prior experience with contact lens wear
- Healthy ocular surface examination
- Ability and willingness to provide written informed consent
Exclusion Criteria:
- History of corneal pathology
- Previous ocular surgery
- Active ocular disease
- Systemic disease affecting the eyes
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ander
- Toewijzing: Gerandomiseerd
- Interventioneel model: Crossover-opdracht
- Masker: Geen (open label)
Aantal wapens
Wapens en interventies
Deelnemersgroep / ArmDeelnemersgroep / Arm |
Interventie / BehandelingInterventie / Behandeling |
|---|---|
|
Ander: ASD First, Modified Periballast Second
Participants received the accelerated stabilization design lens at the first fitting session and the modified periballast lens at the second fitting session after a 4-day interval.
|
Commercially available soft toric contact lens composed of senofilcon A, with an 8.6-mm base curve and 14.5-mm diameter, using an accelerated stabilization design.
Commercially available soft toric contact lens composed of lotrafilcon B, with an 8.7-mm base curve and 14.5-mm diameter, using a modified periballast stabilization design.
|
|
Ander: Modified Periballast First, ASD Second
Participants received the modified periballast lens at the first fitting session and the accelerated stabilization design lens at the second fitting session after a 4-day interval.
|
Commercially available soft toric contact lens composed of senofilcon A, with an 8.6-mm base curve and 14.5-mm diameter, using an accelerated stabilization design.
Commercially available soft toric contact lens composed of lotrafilcon B, with an 8.7-mm base curve and 14.5-mm diameter, using a modified periballast stabilization design.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Overall Mean Absolute Contact Lens Rotation
Tijdsspanne: 30 minutes after lens insertion during each fitting session
|
Absolute lens rotation was measured in degrees using slit-lamp biomicroscopy in five gaze positions (primary, right, left, upward, and downward gaze).
For each lens design, the overall mean absolute rotation was calculated as the average of the absolute rotation measurements across the five gaze positions.
|
30 minutes after lens insertion during each fitting session
|
Medewerkers en onderzoekers
Sponsor
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Studie start
Primaire voltooiing (Werkelijk)
Primaire voltooiing
Studie voltooiing (Werkelijk)
Studie voltooiing
Studieregistratiedata
Eerst ingediend
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Eerst geplaatst
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update geplaatst
Laatste update ingediend die voldeed aan QC-criteria
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
Andere studie-ID-nummers
- TORIC-ROT-2026-01
- 2026-GOKAEK-267_2026.04.01_98 (Andere identificatie: Yozgat Bozok University Clinical Research Ethics Committee)
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
IPD-tijdsbestek voor delen
IPD-toegangscriteria voor delen
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .