Rotational Stability of Two Soft Toric Contact Lens Designs
Comparison of Rotational Behavior of Soft Toric Contact Lenses With Different Stabilization Designs and Their Association With Ocular Biometric Parameters
Studieoversikt
Status
Status
Forhold
Forhold
Intervensjon / Behandling
Intervensjon / Behandling
Studietype
Studietype
Registrering (Faktiske)
Registrering
Fase
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
Yozgat
-
Yozgat, Yozgat, Tyrkia (Türkiye), 66100
- Yozgat Bozok University Research and Application Hospital
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Voksen
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
- Adults with astigmatic refractive error suitable for correction with the -commercially available toric contact lenses used in the study
- No prior experience with contact lens wear
- Healthy ocular surface examination
- Ability and willingness to provide written informed consent
Exclusion Criteria:
- History of corneal pathology
- Previous ocular surgery
- Active ocular disease
- Systemic disease affecting the eyes
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Annen
- Tildeling: Randomisert
- Intervensjonsmodell: Crossover-oppdrag
- Masking: Ingen (Open Label)
Antall våpen
Våpen og intervensjoner
Deltakergruppe / ArmDeltakergruppe / Arm |
Intervensjon / BehandlingIntervensjon / Behandling |
|---|---|
|
Annen: ASD First, Modified Periballast Second
Participants received the accelerated stabilization design lens at the first fitting session and the modified periballast lens at the second fitting session after a 4-day interval.
|
Commercially available soft toric contact lens composed of senofilcon A, with an 8.6-mm base curve and 14.5-mm diameter, using an accelerated stabilization design.
Commercially available soft toric contact lens composed of lotrafilcon B, with an 8.7-mm base curve and 14.5-mm diameter, using a modified periballast stabilization design.
|
|
Annen: Modified Periballast First, ASD Second
Participants received the modified periballast lens at the first fitting session and the accelerated stabilization design lens at the second fitting session after a 4-day interval.
|
Commercially available soft toric contact lens composed of senofilcon A, with an 8.6-mm base curve and 14.5-mm diameter, using an accelerated stabilization design.
Commercially available soft toric contact lens composed of lotrafilcon B, with an 8.7-mm base curve and 14.5-mm diameter, using a modified periballast stabilization design.
|
Hva måler studien?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Overall Mean Absolute Contact Lens Rotation
Tidsramme: 30 minutes after lens insertion during each fitting session
|
Absolute lens rotation was measured in degrees using slit-lamp biomicroscopy in five gaze positions (primary, right, left, upward, and downward gaze).
For each lens design, the overall mean absolute rotation was calculated as the average of the absolute rotation measurements across the five gaze positions.
|
30 minutes after lens insertion during each fitting session
|
Samarbeidspartnere og etterforskere
Sponsor
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Studiestart
Primær fullføring (Faktiske)
Primær fullføring
Studiet fullført (Faktiske)
Studiet fullført
Datoer for studieregistrering
Først innsendt
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Først lagt ut
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Sist oppdatering lagt ut
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
Andre studie-ID-numre
- TORIC-ROT-2026-01
- 2026-GOKAEK-267_2026.04.01_98 (Annen identifikator: Yozgat Bozok University Clinical Research Ethics Committee)
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
IPD-planbeskrivelse
IPD-delingstidsramme
Tilgangskriterier for IPD-deling
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .