A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy (mAInstream)
A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy: an International Multicenter Randomized Controlled Trial
To overcome non-neoplastic polyp (NNP) resections, computer-aided diagnosis (CADx) systems have been developed. In a meta-analysis, the performance of CADx systems was superior to endoscopists. The proportion of incorrect predictions could be significantly reduced with CADx assistance. It was reported that autonomous AI prediction could achieve an agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value compared to the histology as gold standard. Lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced under the 'diagnose-and-leave' strategy.
Nevertheless, almost all existing literature reporting the efficacy of CADx were simulated studies and focused on the diagnostic accuracy (i.e. all polyps were ultimately resected for histopathology). There is a lack of real-world data with hard clinical endpoints to support its implementation. A recent RCT compared leave-in-situ and resect-all strategy with real-time CADx in both arms. Using ADR as the surrogate marker, it was shown that the leave-in-situ strategy with CADx support was non-inferior. The major limitations of this RCT were that: i) CADx were activated in both arms - the pure CADx effect could not be demonstrated; ii) 'resect-all' strategy was not a real-world practice especially for diminutive rectosigmoid polyps; iii) the interaction and decision making between AI and human was not documented and uncertain.
A well-designed RCT is warranted to evaluate the pure CADx effect on reducing NNP resections (enhance treatment efficacy) while maintaining the benchmark of ADR (safe implementation). In addition, AI-measured metrics may objectively validate the procedural quality for performance tracking and auditing purposes. If the above points are proven, AI-assisted colonoscopy would become the 'mainstream' in CRC prevention.
Studie Overzicht
Toestand
Toestand
Conditie
Conditie
Interventie / Behandeling
Interventie / Behandeling
Gedetailleerde beschrijving
In a meta-analysis, the performance of CADx systems was superior to endoscopists, with pooled sensitivity and specificity of 92.3% and 89.8% respectively. The proportion of incorrect predictions could be significantly reduced by 12% with CADx assistance. It was reported that autonomous AI prediction could achieve a 91.5% agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value of 97.6% compared to the histology as gold standard. 82% of lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced by 6.9-18.9% under the 'diagnose-and-leave' strategy.
Studietype
Studietype
Inschrijving (Geschat)
Inschrijving
Fase
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
Studiecontact
- Naam: Li
- Telefoonnummer: +85246572604
- E-mail: venusli@cuhk.edu.hk
Deelname Criteria
Geschiktheidscriteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Aged 45-85 years old;
- Undergoing elective colonoscopy for screening, surveillance or diagnostic indication;
- Informed consented.
Exclusion Criteria:
- Contraindication for colonoscopy (e.g. intestinal obstruction);
- Contraindication for polypectomy (e.g. active gastrointestinal bleeding, uninterrupted anticoagulants);
- Prior surgical resection of colon;
- High-risk group of CRC (e.g. personal history of CRC, familial polyposis syndrome, inflammatory bowel disease);
- Advanced comorbidity (defined as American Society of Anesthesiologists grade 4 or above).
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Screening
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Aantal wapens
Wapens en interventies
Deelnemersgroep / ArmDeelnemersgroep / Arm |
Interventie / BehandelingInterventie / Behandeling |
|---|---|
|
Geen tussenkomst: CADe
In the CADe mode, an alert box will be automatically displayed on the screen when a suspicious lesion is detected. |
|
|
Actieve vergelijker: CADe/CADx
In this arm, when a suspicious lesion is detected, an alert box and a prediction on the histopathology (neoplastic vs non-neoplastic) will be generated by the underlying AI algorithm and displayed. |
A novel all-in-one AI system for colonoscopy (GI Genius™ ColonPro™, version 4.0.0, Medtronic plc, Minneapolis, United States) is developed as a pre-installed software in a plug-in device which is compatible with all existing endoscopes and processors. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Primary endpoints (1)
Tijdsspanne: 3 years
|
Superiority: neoplastic to non-neoplastic polyp (NNP) ratio, defined as the total number of neoplastic polyps divided by the number of NNP per group. (indicating the treatment efficacy) |
3 years
|
|
Primary Endpoints (2)
Tijdsspanne: 3 years
|
Non-inferiority: adenoma detection rate (ADR), defined as proportion of subjects with at least one histologically confirmed adenoma in the colonoscopies. (indicating the safety margin for implementation) |
3 years
|
Medewerkers en onderzoekers
Sponsor
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Studie start
Primaire voltooiing (Geschat)
Primaire voltooiing
Studie voltooiing (Geschat)
Studie voltooiing
Studieregistratiedata
Eerst ingediend
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Eerst geplaatst
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update geplaatst
Laatste update ingediend die voldeed aan QC-criteria
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
Andere studie-ID-nummers
- NTEC-CREC-2026.416
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .