A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy (mAInstream)
A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy: an International Multicenter Randomized Controlled Trial
To overcome non-neoplastic polyp (NNP) resections, computer-aided diagnosis (CADx) systems have been developed. In a meta-analysis, the performance of CADx systems was superior to endoscopists. The proportion of incorrect predictions could be significantly reduced with CADx assistance. It was reported that autonomous AI prediction could achieve an agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value compared to the histology as gold standard. Lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced under the 'diagnose-and-leave' strategy.
Nevertheless, almost all existing literature reporting the efficacy of CADx were simulated studies and focused on the diagnostic accuracy (i.e. all polyps were ultimately resected for histopathology). There is a lack of real-world data with hard clinical endpoints to support its implementation. A recent RCT compared leave-in-situ and resect-all strategy with real-time CADx in both arms. Using ADR as the surrogate marker, it was shown that the leave-in-situ strategy with CADx support was non-inferior. The major limitations of this RCT were that: i) CADx were activated in both arms - the pure CADx effect could not be demonstrated; ii) 'resect-all' strategy was not a real-world practice especially for diminutive rectosigmoid polyps; iii) the interaction and decision making between AI and human was not documented and uncertain.
A well-designed RCT is warranted to evaluate the pure CADx effect on reducing NNP resections (enhance treatment efficacy) while maintaining the benchmark of ADR (safe implementation). In addition, AI-measured metrics may objectively validate the procedural quality for performance tracking and auditing purposes. If the above points are proven, AI-assisted colonoscopy would become the 'mainstream' in CRC prevention.
Descripción general del estudio
Estado
Estado
Condiciones
Condiciones
Intervención / Tratamiento
Intervención / Tratamiento
Descripción detallada
In a meta-analysis, the performance of CADx systems was superior to endoscopists, with pooled sensitivity and specificity of 92.3% and 89.8% respectively. The proportion of incorrect predictions could be significantly reduced by 12% with CADx assistance. It was reported that autonomous AI prediction could achieve a 91.5% agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value of 97.6% compared to the histology as gold standard. 82% of lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced by 6.9-18.9% under the 'diagnose-and-leave' strategy.
Tipo de estudio
Tipo de estudio
Inscripción (Estimado)
Inscripción
Fase
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
Estudio Contacto
- Nombre: Li
- Número de teléfono: +85246572604
- Correo electrónico: venusli@cuhk.edu.hk
Criterios de participación
Criterio de elegibilidad
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Aged 45-85 years old;
- Undergoing elective colonoscopy for screening, surveillance or diagnostic indication;
- Informed consented.
Exclusion Criteria:
- Contraindication for colonoscopy (e.g. intestinal obstruction);
- Contraindication for polypectomy (e.g. active gastrointestinal bleeding, uninterrupted anticoagulants);
- Prior surgical resection of colon;
- High-risk group of CRC (e.g. personal history of CRC, familial polyposis syndrome, inflammatory bowel disease);
- Advanced comorbidity (defined as American Society of Anesthesiologists grade 4 or above).
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Poner en pantalla
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Número de brazos
Armas e Intervenciones
Grupo de participantes/brazoGrupo de participantes/brazo |
Intervención / TratamientoIntervención / Tratamiento |
|---|---|
|
Sin intervención: CADe
In the CADe mode, an alert box will be automatically displayed on the screen when a suspicious lesion is detected. |
|
|
Comparador activo: CADe/CADx
In this arm, when a suspicious lesion is detected, an alert box and a prediction on the histopathology (neoplastic vs non-neoplastic) will be generated by the underlying AI algorithm and displayed. |
A novel all-in-one AI system for colonoscopy (GI Genius™ ColonPro™, version 4.0.0, Medtronic plc, Minneapolis, United States) is developed as a pre-installed software in a plug-in device which is compatible with all existing endoscopes and processors. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Primary endpoints (1)
Periodo de tiempo: 3 years
|
Superiority: neoplastic to non-neoplastic polyp (NNP) ratio, defined as the total number of neoplastic polyps divided by the number of NNP per group. (indicating the treatment efficacy) |
3 years
|
|
Primary Endpoints (2)
Periodo de tiempo: 3 years
|
Non-inferiority: adenoma detection rate (ADR), defined as proportion of subjects with at least one histologically confirmed adenoma in the colonoscopies. (indicating the safety margin for implementation) |
3 years
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Inicio del estudio
Finalización primaria (Estimado)
Finalización primaria
Finalización del estudio (Estimado)
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Publicado por primera vez
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización publicada
Última actualización enviada que cumplió con los criterios de control de calidad
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
Otros números de identificación del estudio
- NTEC-CREC-2026.416
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .