Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy (mAInstream)

21 de septiembre de 2026 actualizado por: Louis Ho Shing Lau, Chinese University of Hong Kong

A Novel Multi-functional Artificial Intelligence System on Treatment Efficacy and Implementation in Colonoscopy: an International Multicenter Randomized Controlled Trial

To overcome non-neoplastic polyp (NNP) resections, computer-aided diagnosis (CADx) systems have been developed. In a meta-analysis, the performance of CADx systems was superior to endoscopists. The proportion of incorrect predictions could be significantly reduced with CADx assistance. It was reported that autonomous AI prediction could achieve an agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value compared to the histology as gold standard. Lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced under the 'diagnose-and-leave' strategy.

Nevertheless, almost all existing literature reporting the efficacy of CADx were simulated studies and focused on the diagnostic accuracy (i.e. all polyps were ultimately resected for histopathology). There is a lack of real-world data with hard clinical endpoints to support its implementation. A recent RCT compared leave-in-situ and resect-all strategy with real-time CADx in both arms. Using ADR as the surrogate marker, it was shown that the leave-in-situ strategy with CADx support was non-inferior. The major limitations of this RCT were that: i) CADx were activated in both arms - the pure CADx effect could not be demonstrated; ii) 'resect-all' strategy was not a real-world practice especially for diminutive rectosigmoid polyps; iii) the interaction and decision making between AI and human was not documented and uncertain.

A well-designed RCT is warranted to evaluate the pure CADx effect on reducing NNP resections (enhance treatment efficacy) while maintaining the benchmark of ADR (safe implementation). In addition, AI-measured metrics may objectively validate the procedural quality for performance tracking and auditing purposes. If the above points are proven, AI-assisted colonoscopy would become the 'mainstream' in CRC prevention.

Descripción general del estudio

Estado

Aún no reclutando

Condiciones

Intervención / Tratamiento

Descripción detallada

In a meta-analysis, the performance of CADx systems was superior to endoscopists, with pooled sensitivity and specificity of 92.3% and 89.8% respectively. The proportion of incorrect predictions could be significantly reduced by 12% with CADx assistance. It was reported that autonomous AI prediction could achieve a 91.5% agreement with the standard pathology-based surveillance intervals. In a prospective study targeting diminutive rectosigmoid polyps, CADx achieved a negative predictive value of 97.6% compared to the histology as gold standard. 82% of lesions were amendable for a leave-in-situ strategy, suggesting a potential to reduce the burden of unnecessary polypectomies. It was estimated that the average colonoscopy cost and annual reimbursement could be reduced by 6.9-18.9% under the 'diagnose-and-leave' strategy.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

2818

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

45 años a 85 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  1. Aged 45-85 years old;
  2. Undergoing elective colonoscopy for screening, surveillance or diagnostic indication;
  3. Informed consented.

Exclusion Criteria:

  1. Contraindication for colonoscopy (e.g. intestinal obstruction);
  2. Contraindication for polypectomy (e.g. active gastrointestinal bleeding, uninterrupted anticoagulants);
  3. Prior surgical resection of colon;
  4. High-risk group of CRC (e.g. personal history of CRC, familial polyposis syndrome, inflammatory bowel disease);
  5. Advanced comorbidity (defined as American Society of Anesthesiologists grade 4 or above).

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Poner en pantalla
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Sin intervención: CADe

In the CADe mode, an alert box will be automatically displayed on the screen when a suspicious lesion is detected.

Comparador activo: CADe/CADx

In this arm, when a suspicious lesion is detected, an alert box and a prediction on the histopathology (neoplastic vs non-neoplastic) will be generated by the underlying AI algorithm and displayed.

A novel all-in-one AI system for colonoscopy (GI Genius™ ColonPro™, version 4.0.0, Medtronic plc, Minneapolis, United States) is developed as a pre-installed software in a plug-in device which is compatible with all existing endoscopes and processors.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Primary endpoints (1)
Periodo de tiempo: 3 years

Superiority: neoplastic to non-neoplastic polyp (NNP) ratio, defined as the total number of neoplastic polyps divided by the number of NNP per group. (indicating the treatment efficacy)

3 years
Primary Endpoints (2)
Periodo de tiempo: 3 years

Non-inferiority: adenoma detection rate (ADR), defined as proportion of subjects with at least one histologically confirmed adenoma in the colonoscopies. (indicating the safety margin for implementation)

3 years

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

30 de octubre de 2026

Finalización primaria (Estimado)

31 de diciembre de 2028

Finalización del estudio (Estimado)

30 de septiembre de 2029

Fechas de registro del estudio

Enviado por primera vez

8 de septiembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

21 de septiembre de 2026

Publicado por primera vez (Actual)

28 de septiembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

28 de septiembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

21 de septiembre de 2026

Última verificación

1 de septiembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • NTEC-CREC-2026.416

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

Sí

producto fabricado y exportado desde los EE. UU.

Sí

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .