Detaljert beskrivelse
The intubating Laryngeal Tube Suction-Disposable (iLTS-D) (VBM Medizintechnik GmbH, Sulz, Germany) is a new updated version of the Laryngeal Tube-Suction Disposable (LTS-D) It has a ventilator channel with a 13.5mm internal diameter, which enables the passage of an Endotracheal Tube (ETT) either blindly or with fiberoptic guidance. Similarly As in to the LTS-D, the iLTS-D also has a separate channel for the purpose of placement of gastric tubes placement up to a size of 18 Fr.
The iLTS-D comes in one size. According to the depth of insertion, this device is equivalent to size 4 for patients 175patients 175 to 190 cm tall, or size 5 for patients taller than 190 cm. The iLTS-D is provided by the manufacturer with a compatible 7.5mm ETT and with a plastic stabilizer for removal of the device.
The current randomized study was designed to assess the success rate of blind and fiberoptic endotracheal intubation using iLTS-D, in comparison with the and Ambu® AuraGain™ in adult patients under general anesthesia
Studietype
Studietype
Registrering (Forventet)
Registrering
Fase
Fase
- Ikke aktuelt
Deltakelseskriterier
Kvalifikasjonskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
American Society Anesthesiology I and II
Exclusion Criteria:
Difficult intubation, Cervical pathology
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Crossover-oppdrag
- Masking: Enkelt
Antall våpen
Våpen og intervensjoner
Deltakergruppe / ArmDeltakergruppe / Arm |
Intervensjon / BehandlingIntervensjon / Behandling |
|---|---|
|
Aktiv komparator: Intubating laryngeal Tube Suction
|
Intuberende larynxrørsuging
Ambu AuraGain larynxmaske
|
|
Aktiv komparator: Ambu AuraGain Laryngeal Mask
|
Intuberende larynxrørsuging
Ambu AuraGain larynxmaske
|
Hva måler studien?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Time to performe blind intubation measure in second
Tidsramme: 30 seconds
|
30 seconds
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Time to performe fiberoptic intubation in second
Tidsramme: 60 seconds
|
60 seconds
|
Samarbeidspartnere og etterforskere
Sponsor
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart
Studiestart
Primær fullføring (Forventet)
Primær fullføring
Studiet fullført (Forventet)
Studiet fullført
Datoer for studieregistrering
Først innsendt
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Anslag)
Først lagt ut
Oppdateringer av studieposter
Sist oppdatering lagt ut (Anslag)
Sist oppdatering lagt ut
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Andre studie-ID-numre
Andre studie-ID-numre
- BnaiZionMC-16-LG-005
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .